2N 2Wire How To Use Download Page 2

 

Product use

 

 

Install 

2N® 2Wire

 master unit where your Ethernet cable ends and 2-cable wiring begins. 

 

Plug in Ethernet and 2 cable wiring into the master unit. 

 

Install 

2N® 2Wire

 slave unit where you need convert 2-cable wiring back to Ethernet at remote 

location. Please observe polarity of the 2 wires. 

 

Connect provided power supply to master unit. 

 

Any of the units can be master or slave. Master unit is the one with connected power supply 

while slave is powered via 2 wires. 

 

Blue Power LED indicators should indicate that both units are powered. 

 

Both BNC and PoE green LED should be blinking, thus signalling the established connection and 

data transmission. 

 

 

Specification

 

 

Speed : 10/100 Base T, half/full duplex, auto-negotiation 

 

IEEE 802.3 af/at 40Watt Compliant PoE+ 

 

Cable Type : 2Wire, Cat 5e., Cat 6. or Similar 

 

Impedance : 25Ω to 100Ω 

 

Transmit Coverage : Typical 720ft (220m) @ Cat6 with PoE at far end; up to 2460ft (750m) 

possible; depends on wiring and interference 

LED Indicators

 

 

Power : Blue 

– Power ON 

 

BNC : Green 

– Link ON 

 

PoE : Green 

– Link ON 

 

Summary of Contents for 2Wire

Page 1: ...re twisted pair cabling for IP intercom connection including PoE power supply works on other wiring as well but can be of mixed result Long range Ethernet extension over 2 wires or coax Easy configuration no IP address and network setup required plug play Includes what should you get with the delivery 2 piece converter units with Coax 2 wire adapter 1 piece power supply adapter excludes NZ Power L...

Page 2: ...ith connected power supply while slave is powered via 2 wires Blue Power LED indicators should indicate that both units are powered Both BNC and PoE green LED should be blinking thus signalling the established connection and data transmission Specification Speed 10 100 Base T half full duplex auto negotiation IEEE 802 3 af at 40Watt Compliant PoE Cable Type 2Wire Cat 5e Cat 6 or Similar Impedance ...

Page 3: ...in a search mode Pick up the other unit and repeat the procedure When you let go of the button behind the LED diode of PoE both units will start to blink After both units stop blinking the Power and BNC LED diodes will be shining telling you that both units are paired together 2N 2Wire Unjoining procedure In case you want to unjoin two units so they can work with a different unit pick the unit up ...

Page 4: ... for the total of cable run must meet the criteria as advised ie total length must not exceed 220m with PoE and 750m with the far end device powered locally Also in some instances a 48Vdc PoE power supply may be needed at the distant end as shown in the last image If you are using more than one slave unit connected to a master unit we recommend the use of a power supply also on the side of the sla...