RESETTING THE SENSOR
Before programming the image sensor into a new network,
you must reset it as follows:
1. Insert a paperclip into the hole on the front of the
sensor to access the
Reset
button.
2. Press and hold the
Reset
button for three (3) seconds.
This power cycles the sensor.
3. Hold down the
Reset
button for 10 seconds. When the
LED begins flashing, the sensor is reset and is removed
from the existing network.
NOTE
: If the image sensor is not communicating with its
network, you can use the
Reset
button to clear the sensor
from that network. If the sensor is still communicating with
its network, clear sensor by deleting it from the control
panel.
SENSOR RESET HOLE
WIFI TO THE ON-SITE ROUTER (WPS)
1. If the on-site router supports WiFi Protected Setup (WPS), press
the
WPS
button (A) until the routher enters WPS mode (
the
indicators will differ slightly from router to router). This gives the
routher the ability to “listen” for a new WPS device.
2. Press the
WPS
button (A) on the camera. This action causes the
camera to announce itself to the router as a WPS device. While the
camera is in WPS mode, the LED on the camera blinks YELLOW.
3. Do not press any buttons on the camera until its LED illuminates
GREEN, which indicates the camera has successfully connected
to the
network.
4. From the Alarm.com website add and configure the camera.
WIFI TO THE ON-SITE ROUTER
1. Connect the camera directly to the router using an ethernet cable.
2. From the Alarm.com website add and configure the camera to
connect using WiFi.
3. Disconnect the power cable from the camera.
4. Disconnect the Ethernet cable from the camera. A WiFi connection
will be established.
ETHERNET TO THE ROUTER
1. Connect the camera directly to the router using an Ethernet cable.
2. From the Alarm.com website add and configure the camera.
NOTE
: Access points and cellular “hot spots” will not work with the
HD100 Camera. You must have a router installed in the home.
LED
WPS
RESET
LED States
State
LED Pattern
Normal Operation
Solid Green
Connectivity Problems
Blinking Red
WPS Transaction in Progress
Blinking Yellow
Booting
Solid Yellow
77-000010-001 Rev D
For technical support in the USA and Canada:
855-2GIG-TECH (855-244-4832)
or visit the
2GIG dealer site at
dealer.2gig.com
, or email us at
.
For technical support outside of the USA and Canada, contact your regional distributor.
Copyright © 2014 Linear LLC.
1.
CREATE AN ALARM.COM CUSTOMER ACCOUNT
.
When creating an
account on the Alarm .com dealer site, enter the serial number for the
2GIG CDMA Cell Radio Module (2GIG-GC CDMA).
2.
VERIFY THE CELL RADIO AND TRANSCEIVER INSTALLATION
.
Ensure that
the
2GIG-GC CDMA and 2GIG-XCVR2 radio are properly installed and
connected inside the control panel. The firmware version must be v1.10
(or higher).
3.
REGISTER MODULE AND TEST COMMUNICATIONS
.
Power up the panel
and initiate a cell phone test to ensure the communication module is
properly installed and communicating with Alarm.com.
4.
PROGRAM THE SENSOR INTO THE CONTROL PANEL
. Enter the control
panel’s System Configuration module (see page 1).
Select:
RF Sensor # (01 to 48)
to select the desired zone option. Then
tap
Select:
RF Sensor # Type
to select
(04) Interior Follower
,
(10) Interior
with Delay
, or
(3) No Response Type
. Then tap
Select:
RF Sensor # Equipment Type
to select
(1) Motion
. Then tap
Select:
RF Sensor Equipment Code
to select
(9999) Alarm.com Image
Sensor
. Then tap
Enter:
RF Sensor # Serial Number (Read Only)
Use the MAC address
(must be learned into the panel).
Select:
RF Sensor # Equipment Age (0 to 1)
to select
(0) New
or
(1)
Existing
. Then tap
Select:
RF Sensor # Loop Number (0 to 3)
to select
(1) 1
. Then tap
Select:
RF Sensor # Dialer Delay (0 to 1)
to select
(0) Disabled
. Then
tap
Construct:
RF Sensor # Voice Descriptor
Tap
Insert
. Then tap
to scroll through the available words or
enter the 3-digit code associated with the desired word. See
Voice Descriptors
on page 4. Then tap
Select:
RF Sensor # Reports (0 to 1)
to select
(1) Enabled
. Then tap
Select:
RF Sensor # Supervised (0 to 1)
to select
(1) Enabled
. Then
tap
Select:
RF Sensor # Chime (00 to 13)
to select
(00) Disabled
(A chime
is not recommended). Then tap
Continue by programming the next image sensor or tap
Skip
, then
End
,
and then make sure a checkmark appears in the
Save Changes
box and
tap
Exit
.
6.
Perform a cell phone test to ensure that the updated equipment list is
sent to Alarm.com.
REQUIREMENTS
●
Go!Control Panel (Firmware Version 1.10 or higher)
●
2GIG-Cell Radio Module
●
2GIG Transceiver Module (2GIG-XCVR2-345)
Installing the Indoor HD Camera (2GIG-CAM-HD100)*
Control Panel Firmware Version 1.13
*not available in all regions
RESET TO DEFAULTS
Press and hold button (B) until the camera LED
changes to yellow (approximately 10 seconds).
When the camera LED changes to yellow, release
button (B) to reset the camera to factory defaults.
For best results, program one (1) image sensor into the
panel at a time and insert the batteries (to trip the sensor)
after placing the panel into learning mode.
Installing the Image Sensor (2GIG-IMAGE1)*
Control Panel Firmware Version 1.13
*not available in all regions