1
Copyright © 2018 Nortek Security & Control
Figure 2.
Opening the Detector Case
2GIG-FT6-345
FLOOD AND TEMPERATURE DETECTOR
DETECTOR
DOUBLE SIDED ADHESIVE TAPE
LITHIUM BATTERY
LITHIU
M
ALIGN DOTS
BATTERY TERMINAL
NEGATIVE (-)
BATTERY TERMINAL
POSITIVE (+)
Replacing Battery
1. Open Detector Case (as shown in Figures 2 and 3).
2. Remove old battery, and dispose of properly
(following state regulations).
3. Install new battery.
4. Close Detector Case.
INSTALLATION INSTRUCTIONS
The 2GIG-FT6-345 is a fully supervised, one-way 345 MHz detector. It will detect wet
or dry floor conditions as well as the ambient temperature. The detector reports wet/
dry conditions and when specific temperature thresholds are exceeded.
Flood Conditions
Once the detector probe detects the presence of water, the integral transmitter will
immediately send a loop 3 wet alarm transmission to the panel. The detector will also
send a restore (dry) report when the presence of water is no longer detected. The
detector is capable of detecting clean or dirty fresh water, salt water and tap water.
The 2GIG-FT6-345 utilizes a unique design that can detect leaks dripping onto its
top or if there is water under the device. This dual sensing technology is perfect for
placement under P Traps or hoses that may leak, giving a warning just as the leak
starts. If a leak occurs at a different location, it will also be detected when the water
is sensed under the device.
Temperature Conditions
Heat:
1. If the temperature is more than 95° F (35°C) for three (3) minutes, the detector
will send a loop 2 transmission.
2. If the temperature is less than 95°F (35°C) for three (3) minutes, the detector
will send a loop 2 clear.
Cold:
1. If the temperature is less than 41°F (5°C) for three (3) minutes, the detector will
send a loop 1 transmission.
2. In the temperature is more than 41°F (5°C) three (3) minutes, the detector will
send a loop 1 clear.
Contents
Verify that the package includes the following:
• 1 — 2GIG Flood/Temperature Detector
• 1 — 3V CR123A Lithium Battery (Installed)
• 1 — Double sided adhesive tape
Figure 1.
Temperature/Flood
Detector Contents
Grip the base of the detector case. Turn the top cover counter-clockwise to align the
dots, then separate the detector case.
Figure 3.
Installing New Battery
DETECTOR
WATER
Installing Water Detector
The 2GIG-FT6-345 Flood and Temperature Detector can be easily placed in any
location. If placed specifically under a potential leak source, use the included optional
double sided adhesive tape to secure it in the desired location (see
Figure 4
).
Figure 4.
Suggested Installation Locations
Place the detector in locations
that have the potential of
water leaks or flooding.
For example:
• Under the sink pipes
• Adjacent to water heaters
• Adjacent to toilets
• Adjacent to bathtubs or
showers
• Under or near your
dishwasher