background image

2

    Copyright © 2014 Linear LLC

Go!Bridge IP Communicator |  Installation Instructions

NOTE: 

If

 

the

 

900MHz

 

LED

 

illuminates

 

in

 

GREEN

 

(the

 

lower

 

LED),

 

verify

 

that

 

the

 

network

 

cable

 

is

 

not

 

connected

 

to

 

the

 

Go!Bridge

 

IP

 

Communicator.

 

If

 

the

 

cable

 

is

 

disconnected

 

and

 

it

 

is

 

still

 

illuminated

 

GREEN,

 

use

 

the

 

end

 

of

 

an

 

open

 

paperclip

 

to

 

press

 

and

 

release

 

the

 

recessed

 

Reset

 

button.

 

The

 

button

 

is

 

located

 

inside

 

the

 

small

 

hole

 

on

 

the

 

port

 

side

 

of

 

the

 

Go!Bridge

 

IP

 

Communicator,

 

directly

 

above

 

the

 

Ethernet

 

port.

 

This

 

restores

 

the

 

factory

 

settings.

 

See

 

Figure

 

3

  

Go!Bridge

 

IP

 

Communicator

 

Rear

 

View—Ports

 

and

 

Recessed

 

Reset

 

Button.

Figure 3  

Go!Bridge IP Communicator Rear View

Ports and 

Recessed Reset Button

5

After

 

the

 

Go!Bridge

 

IP

 

Communicator

 

is

 

powered

 

ON,

 

continue

 

with

 

Programming

 

the

 

Go!Bridge

 

IP

 

Communicator

 

into

 

the

 

Control

 

Panel

.

Programming the Go!Bridge IP Communicator 
into the Control Panel

Use

 

these

 

steps

 

to

 

place

 

the

 

control

 

panel

 

and

 

Go!Bridge

 

IP

 

Communicator

 

in

 

learning

 

mode.

 

This

 

gives

 

the

 

control

 

panel

 

the

 

ability

 

to

 

learn

 

the

 

network

 

settings

 

transmitted

 

by

 

the

 

Go!Bridge

 

IP

 

Communicator.

 

NOTE: 

To

 

scroll

 

between

 

op ons

 

on

 

the

 

control

 

panel,

 

tap

 

the

 ← 

and

 → 

arrows.

 

To

 

move

 

to

 

the

 

previous

 

or

 

next

 

prompt

 

tap

 

the

 

↑ 

and

 ↓ 

arrows.

 

1

Connect

 

an

 

Ethernet

 

cable

 

(not

 

included)

 

to

 

the

 

router

 

and

 

Go!Bridge

 

IP

 

Communicator.

 

Do

 

not

 

plug

 

the

 

cable

 

into

 

the

 

uplink

 

port.

IMPORTANT: 

For

 

compliance

 

with

 

UL

 

1023:

 

Household

 

Burglar

Alarm

 

System

 

Units

,

 

the

 

Go!Bridge

 

must

 

be

 

installed

 

in

 

the

 

same

 

room

 

as

 

the

 

Internet

 

modem

 

or

 

router.

2

Ensure

 

the

 

control

 

panel

 

is

 

powered

 

ON.

 

Then

 

tap

 

the

 

Home

 

 

button.

 

3

Tap

 

the

 

system

 

logo

 

in

 

the

 

lower

right

 

corner

 

of

 

the

 

control

 

panel

 

Home

 

screen.

4

At

 

the

 

Enter

 

Your

 

Code

 

screen,

 

enter

 

the

 

four

 

(4)

digit

 

master

 

installer

 

code

 

to

 

go

 

to

 

the

 

Installer

 

Toolbox

 

(1

 

of

 

2)

 

screen.

5

At

 

the

 

Installer

 

Toolbox

 

(1

 

of

 

2)

 

screen,

 

tap

 

System

 

Configuration

.

6

At

 

the

 

Q1:

 

Select

 

RF

 

Sensor

 

#

 

(01

 

to

 

48)

 

screen,

 

tap

 

Go

 

To

.

 

7

At

 

the

 

Enter

 

Question

 

Number

 

(2

 

Digits)

 

screen,

 

enter

 

92

.

8

At

 

Q92

 

Select

 

Network

 

Device

 

(0

 

to

 

1)

,

 

tap

 → 

to

 

scroll

 

to

 

(1)

 

Go!Bridge

 

IP

 

Communicator.

 

Then

 

tap

 ↓

.

9

At

 

Q:

 

Network

 

Device

 

ID

 

(Read

 

Only)

,

 

tap

 

Learn

.

 

This

 

gives

 

the

 

panel

 

the

 

ability

 

to

 

discover

 

the

 

read

only

 

network

 

device

 

ID

 

transmitted

 

by

 

the

 

Go!Bridge

 

IP

 

Communicator.

At

 

the

 

Pair

 

with

 

Xcvr

 

Device

 

screen,

 

the

 

“initiating

 

learning

 

process”

 

message

 

appears.

10

On

 

the

 

Go!Bridge

 

IP

 

Communicator,

 

press

 

and

 

release

 

the

 

Learn

 

button

 

(this

 

is

 

the

 

small,

 

black

 

plastic

 

button

 

on

 

the

 

LED

 

side

 

of

 

the

 

Go!Bridge

 

IP

 

Communicator

 

below

 

the

 

900MHz

 

LED).

 

This

 

transmits

 

the

 

device

 

ID

 

to

 

the

 

Control

 

Panel.

 

When

 

the

 

“learn

 

operation

 

succeeded”

 

message

 

appears

 

and

 

the

 

panel

 

displays

 

the

 

Type

 

(Go!Bridge

 

IP

 

Communicator)

 

and

 

ID#

,

 

the

 

Go!Bridge

 

IP

 

Communicator

 

and

 

panel

 

are

 

linked.

 

The

 

900MHz

 

LED

 

on

 

the

 

Go!Bridge

 

IP

 

Communicator

 

also

 

flashes

 

GREEN.

11

At

 

the

 

Pair

 

with

 

Xcvr

 

Device

 

screen,

 

tap

 

OK

.

 

Then

 

tap

 ↓ 

to

 

continue

 

with

 

Configuring

 

the

 

Go!Bridge

 

IP

 

Communicator

 

Settings

 

below.

Configuring the Go!Bridge IP Communicator Settings

1

At

 

the

 

Q:

 

Select

 

Port

 

#

 

(1

 

to

 

8)

 

screen,

 

enter

 

the

 

port

 

number

 

for

 

the

 

third

party

 

monitoring

 

services’

 

server.

 

Then

 

tap

 ↓

.

2

At

 

Q:

 

Used

 

(0

 

to

 

1)

,

 

tap

 → 

to

 

select

 

one

 

(1)

 

of

 

these

 

options:

(0)

 

Disabled

 

(Recommended).

 

This

 

is

 

the

 

default

 

setting.

 

Most

 

users

 

will

 

keep

 

this

 

port

 

disabled.

 

Then

 

tap

 

Next

 

and

 

skip

 

to

 

step

 

3.

OR

(1)

 

Enabled

.

 

Then

 

tap

 ↓

.

 

At

 

the

 

Q:

 

Enter

 

Port

 

Value

 

(0

65535)

 

screen,

 

tap

 ↓ 

to

 

accept

 

the

 

default

 

port

 

value.

 

Next,

 

at

 

the

 

Q:

 

Enter

 

Port

 

Forward

 

IP

 

Address

 

screen,

 

tap

 ↓ 

to

 

accept

 

the

 

address

 

configured

 

by

 

the

 

provider.

 

You

 

can

 

configure

 

up

 

to

 

eight

 

(8)

 

ports.

 

If

 

you

 

are

 

finished

 

configuring

 

ports,

 

tap

 

Next

.

3

At

 

the

 

Summary

 

of

 

Network

 

Device

 

screen,

 

tap

 ↓

.

 

Verify

 

the

 

list

 

of

 

port

 

numbers

 

and

 

forward

 

IP

 

addresses

 

appears

 

as

 

programmed.

 

Then

 

tap

 

Skip

.

4

At

 

Q93

 

Enter

 

Broadband

 

Network

 

Failure

 

Time

 

(1

 

to

 

255)

,

 

enter

 

the

 

desired

 

number

 

of

 

minutes

 

that

 

must

 

pass

 

before

 

a

 

network

 

failure

 

triggers

 

the

 

Control

 

Panel

 

to

 

issue

 

a

 

trouble

 

alert.

 

The

 

default

 

value

 

is

 

30

 

minutes.

 

Then

 

tap

 ↓

.

NOTE: 

A

 

trouble

 

alert

 

consists

 

of

 

an

 

audible

 

beep

 

and

 

the

 

Control

 

Panel’s

 

Home

 

screen

 

displays

 

a

 

trouble

 

message.

5

At

 

Q94

 

Select

 

Broadband

 

Network

 

Failure

 

Report

 

(0

 

or

 

1)

,

 

tap

 → 

to

 

select

 

whether

 

or

 

not

 

to

 

report

 

the

 

broadband

 

network

 

failure

 

to

 

the

 

monitoring

 

service:

(1)

 

Enabled

.

 

This

 

is

 

the

 

default

 

setting.

 

Network

 

failures

 

are

 

reported

 

to

 

monitoring

 

service.

 

OR

(0)

 

Disabled

.

 

Network

 

failures

 

are

 

not

 

reported.

 

6

Tap

 

End

.

7

At

 

the

 

Summary

 

of

 

System

 

Configuration

 

screen,

 

verify

 

the

 

settings.

 

Then

 

tap

 

Save

 

Changes

.

 

8

Tap

 

Exit

 

to

 

the

 

close

 

the

 

System

 

Configuration

 

screen.

 

LED Indicators

The

 

table

 

details

 

the

 

LED

 

indicators

 

on

 

the

 

Go!Bridge

 

IP

 

Communicator.

 

A

Recessed

 

Reset

 

Button

B

Ethernet

 

Port

C

Power

 

Supply

 

Port

Network

 

LED

Globe

 

Icon

Solid

 

GREEN

Indicates

 

the

 

presence

 

of

 

an

 

external

 

network

 

connection.

Flashing

 

GREEN Network

 

cable

 

is

 

plugged

 

in

 

and

 

IP

 

address

 

is

 

actively

 

being

 

assigned.

Solid

 

RED

Network

 

cable

 

unplugged.

900

 

MHz

 

LED

Icon

 

Labeled

 

“900MHz”

Solid

 

GREEN

Linked

 

and

 

communicating

 

with

 

the

 

Control

 

Panel.

Flashing

 

GREEN Linked

 

to

 

the

 

Control

 

Panel.

 

Communication

 

issues

 

exist.

Solid

 

RED

Not

 

linked

 

to

 

the

 

Control

 

Panel,

 

turns

 

solid

 

after

 

a

 

device

 

reset.

Flashing

 

RED

Not

 

linked

 

to

 

the

 

Control

 

Panel.

Summary of Contents for 2GIG-BRDG1-900

Page 1: ...d Access II encryption is already enabled After installing programming and testing the Go Bridge IP Communicator you will need to register a new customer with the third party monitoring service See Registration on page 3 Figure 1 Go Bridge Front View LED Indicators and Learn Button Powering ON the Go Bridge IP Communicator Use these steps to power ON the Go Bridge IP Communicator 1 Attach the powe...

Page 2: ...unicator below the 900MHz LED This transmits the device ID to the Control Panel When the learn operation succeeded message appears and the panel displays the Type Go Bridge IP Communicator and ID the Go Bridge IP Communicator and panel are linked The 900MHz LED on the Go Bridge IP Communicator also flashes GREEN 11 At the Pair with Xcvr Device screen tap OK Then tap to continue with Configuring th...

Page 3: ... comply with FCC Rules and Regulations as Part 15 devices As such they have limited transmitter power and therefore limited range approximately 400 ft A receiver cannot respond to more than one 1 transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies regardless of code settings Changes or modifications to the device may void FCC complianc...

Page 4: ...r electrician as appropriate LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for two 2 years This warranty extends only to wholesale customers who buy direct from Linear LLC or through Linear LLC s normal distribution channels Linear LLC does not warrant this product to consumers Consumers should inquire from their selling dealer as to the nature of th...

Reviews: