
Copyright © 2014 Linear LLC
3
A
summary
screen
displays
the
following
information:
•
Network
Configuration
.
The
network
type
configuration.
•
IP
Address
.
The
IP
Address
for
the
Go!Bridge.
This
is
a
32
‐
bit
numeric
address
that
identifies
the
device
on
the
network.
•
Subnet
Mask
.
The
subnet
mask
for
the
network.
All
devices
that
are
joined
to
a
network
belong
to
a
subnetwork.
•
Gateway
.
The
IP
Address
for
the
access
point
to
the
external
network.
Typically,
this
is
the
IP
Address
of
the
local
network
router
or
node
that
control
traffic
for
your
ISP.
•
MAC
Address
.
This
is
the
Media
Access
Control
(MAC)
Address.
It
is
a
physical
address
that
is
encoded
to
the
Go!Bridge
during
the
manufacturing
process.
Testing
The
Go!Bridge
tests
the
network
connection
to
the
third
‐
party
monitoring
service.
A
report
shows
if
Go!Bridge
has
successfully
connected
(or
failed
to
connect)
to
the
external
server.
Registration
To
register
the
Go!Bridge
with
the
monitoring
service,
refer
to
your
specific
provider’s
registration
instructions.
SPECIFICATIONS
Wireless
Signal
Range
500
ft
(152.4
m),
open
air,
with
Wireless
Control
Panel
Transceiver
Silicon
Labs
SI1001
‐
E
‐
GM2
Transceiver
Frequency
25
channel
frequency
‐
hopping
spread
spectrum,
403
kHz
channel
spacing
(910.2
‐
920.275
MHz)
Modulation
Type
GFSK
modulation,
128
kpbs
RF
Power
+19dBm
Maximum
Ethernet
10/100
BaseT
Dimensions
(L
x
W
x
H)
6.24
x
4.5
x
1
in
(159
x
114
x
25
cm)
Weight
9.6
oz
Housing
Material
Cycoloy™
Resin
C2800
(Rated
to
UL
94
V
‐
0:
Flammability
Standard
)
Color
White
Operating
Temperature
32°
F
to
120.2°
F,
(0°
C
to
+49°
C)
Relative
Humidity
5
‐
95%
Non
‐
Condensing
Operating
Voltage
5VDC
Certification
ETL,
FCC
Part
15,
and
Industry
Canada
IMPORTANT NOTE
Should
the
local
network
lose
Internet
access
due
to
a
power
outage
or
interruption,
the
Go!Bridge
is
not
equipped
with
a
backup
battery
system.
To
best
prepare
for
power
failures
and
to
ensure
the
security
system
maintains
Internet
access
with
the
monitoring
service
for
life
‐
safety
communications
during
power
failures,
the
local
network
must
have
a
dedicated
Uninterrupted
Power
Supply
(UPS)
or
backup
battery
solution
from
a
third
‐
party
manufacturer
in
place.
Linear
LLC
does
not
supply,
provide,
recommend,
or
test
the
Go!Bridge
with
any
UPS
or
battery
backup
solution.
It
is
also
assumed
that
owner’s
Internet
Service
Provider
(ISP)
maintains
a
backup
battery
(or
power
generator)
for
their
remote
network
equipment.
REGULATORY INFORMATION
Wireless Product Notice
Radio
controls
provide
a
reliable
communications
link
and
fill
an
important
need
in
portable
wireless
signaling;
however,
there
are
some
limitations
which
must
be
observed.
•
For
United
States
Installations
Only:
The
radios
are
required
to
comply
with
FCC
Rules
and
Regulations
as
Part
15
devices.
As
such,
they
have
limited
transmitter
power
and
therefore
limited
range
(approximately
400
ft.).
•
A
receiver
cannot
respond
to
more
than
one
(1)
transmitted
signal
at
a
time
and
may
be
blocked
by
radio
signals
that
occur
on
or
near
their
operating
frequencies,
regardless
of
code
settings.
•
Changes
or
modifications
to
the
device
may
void
FCC
compliance.
•
Infrequently
used
radio
links
should
be
tested
regularly
to
protect
against
undetected
interference
or
fault.
•
A
general
knowledge
of
radio
and
its
vagaries
should
be
gained
prior
to
acting
as
a
wholesale
distributor
or
dealer,
and
these
facts
should
be
communicated
to
the
end
users.
ETL Listed
This
device
has
been
tested
by
Intertek
and
is
in
compliance
with
UL
1023:
Household
Burglar
‐
Alarm
System
Units
in
the
United
States
and
Canada.
FCC Part 15 Notice
This
device
complies
with
Part
15
of
the
FCC
Rules.
Operation
is
subject
to
the
following
two
conditions:
1
This
device
may
not
cause
harmful
interference,
and
2
This
device
must
accept
any
interference
received,
including
interference
that
may
cause
undesired
operation.
This
equipment
has
been
tested
and
found
to
comply
with
the
limits
for
Class
B
Digital
Device,
pursuant
to
Part
15
of
the
FCC
Rules.
These
limits
are
designed
to
provide
reasonable
protection
against
harmful
interference
in
a
residential
installation.
This
equipment
generates
and
can
radiate
radio
frequency
energy
and,
if
not
installed
and
used
in
accordance
with
the
instructions,
may
cause
harmful
interference
to
radio
communications.
However,
there
is
no
guarantee
that
interference
will
not
occur
in
a
particular
installation.
If
this
equipment
does
cause
harmful
interference
to
radio
or
television
reception,
which
can
be
determined
by
turning
the
equipment
off
and
on,
the
user
is
encouraged
to
try
to
correct
the
interference
by
one
(1)
or
more
of
the
following
measures.
•
Reorient
or
relocate
the
receiving
antenna
•
Increase
the
separation
between
the
equipment
and
receiver
•
Connect
the
equipment
into
an
outlet
on
a
circuit
different
from
that
to
which
the
receiver
is
connected
•
Consult
the
dealer
or
an
experienced
radio/TV
technician
for
help
Any
changes
or
modifications
not
expressly
approved
by
the
party
responsible
for
compliance
could
void
the
user’s
authority
to
operate
the
equipment.
Les
changements
ou
modifications
non
approuvés
expressément
par
la
partie
responsable
de
la
conformité
pourrait
annuler
l'autorité
de
l'utilisateur
à
faire
fonctionner
l'équipement.
Industry Canada (IC) Compliance
This
device
complies
with
Industry
Canada
license
‐
exempt
RSS
standard(s).
Operation
is
subject
to
the
following
two
conditions:
(1)
this
device
may
not
cause
interference,
and
(2)
this
device
must
accept
any
interference,
including
interference
that
may
cause
undesired
operation
of
the
device.
Le
présent
appareil
est
conforme
aux
CNR
d'Industrie
Canada
applicables
aux
appareils
radio
exempts
de
licence.
L'exploitation
est
autorisée
aux
deux
conditions
suivantes:
(1)
l'appareil
ne
doit
pas
produire
de
brouillage,
et
(2)
l'utilisateur
de
l'appareil
doit
accepter
tout
brouillage
radioélectrique
subi,
même
si
le
brouillage
est
susceptible
d'en
compromettre
le
fonctionnement.
Repairs
to
certified
equipment
should
be
made
by
an
authorized
Canadian
maintenance
facility
designated
by
the
supplier.
Any
repairs
or
alterations
made
by
the
user
to
this
equipment,
or
equipment