background image

Intercom Function

Intercom function can be initiated by any monitor when multi monitors are in-

stalled.

When the monitor is in standby mode, pick up handset, the 

Intercom

 item on 

main menu page will be selected, press 

MENU

 button to enter.

Intercom Call:

 User in one apartment can call other apartments in the sys-

tem, the namelist will be created automatically by the system. Select a name 

on the screen, use   /   button to move upward / downward to select, then 

press 

MENU

 button to dial.

Note:

1. Press "MENU " button again to redial.

2.The user code of each monitor must set different

Inner Call:

 If multi Monitors are installed in the same apartment, select Inner 

Call, all the other Monitors will ring at the same time, whichever Monitor an-

• 

Pick up handset to talk with the visitor, the talking duration time is 90s. To 

end the conversation, please hand up the handset. If the system connects 

two or more Monitors, pick up any Monitor, the others will be automatically 

shut off.

Door Release

During talking state, Press   

UNLOCK

 button to open the door for the visitor.

Entrance Monitoring

When the monitor is in standby mode, press 

MONITOR

 button(or select  

Mon-

itor ...

 item on main menu page), The screen can display the view of outside. 

If multi door stations are installed, select 

Manual Monitor

 item to enter cam-

era switch mode. Select 

Camera 1 ...

 item, the screen will display the image 

from  the first door camera.Similarly. Select 

Camera 2 ...

  item to choose the 

second one. Select 

Camera 3 ...

  item to choose the third one. Select 

Camera 

4 ...

  item to choose the fourth one.  

To end the monitoring, please tap 

MONITOR

 button again.

-5-

Summary of Contents for XT24

Page 1: ...XT24 USER MANUAL EN 2 Wire Video Intercom System Read this manual carefully before using the product and keep it well for future use ...

Page 2: ......

Page 3: ...bell call button connection port DIP switches Total 3 bits can be configured Bit1 reserve Bit2 reserve Bit3 to set the video impendance matching when the video signal is not so good set bit3 to on Terminal Description LCD Screen UNLOCK Button Monitor Button Memo Button Up Button MENU Button Cancel Button Down Button Microphone Speaker Connection Port Mounting Hook Handset Mounting Hook Handset Han...

Page 4: ...e will be seen on screen If nobody answers the call the screen will turn off in 30 seconds automatically Main Menu Monitor Manual Monitor Intercom User Setup Close About OK Select Item Unit Mounting Accessory contents Accessories include a Bracket two 4X25 screws use to fasten the Mounting Bracket 2 wire connectors use to connect with Monitor Installation steps Installation height for indoor monit...

Page 5: ... same time whichever Monitor an Pick up handset to talk with the visitor the talking duration time is 90s To end the conversation please hand up the handset If the system connects two or more Monitors pick up any Monitor the others will be automatically shut off Door Release During talking state Press UNLOCK button to open the door for the visitor Entrance Monitoring When the monitor is in standby...

Page 6: ...n 5 Sonatine 9 Do Re Me 2 Ding Dong 6 Edelweiss 10 Happy Birthday 3 Rain 7 Going Home 11 Jingle Bells 4 For Alice 8 Congratulation 12 Telephone Ring User Setup 1 Door Station Call Tone Intercom Call Tone DoorBell Tone Clock Next Page Exit OK Select Item swers the call conversation is started and the other monitors will stop ringing at the same time Note the user code of all monitors must be same D...

Page 7: ...it Inc The first item is Scene mode selection Total 4 screen modes can be select ed in sequence Normal User Soft and Bright Please note whenever you modify Brightness or Colour item Scene item will be set to User mode automatically The Brightness and Colour item is for the image quality setting adjust the value to get the best image you like Note that all the modifications will be done immediately...

Page 8: ...cel this function How to set the monitor panel on In default mode when receive a calling the master and slave monitors will ring at the same time and just the master monitor can display the image while the slave monitors can not But the settings can be changed you can set the master monitor and all the slave monitors to panel on at the same time when receiving a call just input the code number of ...

Page 9: ...de number of 8014 is used to set the unlock2 on that it can control two locks Note 1 During talking or monitoring state UNLOCK button two unlock icons will be showed Use button to select the item you want and press UNLOCK or MENU button to release the correspond ing door select item to exit 2 Restore to default operation will not change the parameters setting How to set the slave monitor address M...

Page 10: ... 8200 to 8231 is used to controlled the address of 00 to 31 Please refer to the following table 10 Input No User Code Input No User Code Input No User Code 8200 Code 0 8211 Code 11 8222 Code 22 8201 Code 1 8212 Code 12 8223 Code 23 8202 Code 2 8213 Code 13 8224 Code 24 8203 Code 3 8214 Code 14 8225 Code 25 8204 Code 4 8215 Code 15 8226 Code 26 8205 Code 5 8216 Code 16 8227 Code 27 8206 Code 6 8217...

Page 11: ...h please do not use the or ganic impregnant or chemical clean agent If necessary please use a little pure water or dilute soap water to clean the dust 3 Image distortion may occur if the video monitor is mounted too close to magnetic field e g Microwaves TV computer etc 4 Please keep away the monitor from wet high temperature dust caustic and oxidation gas in order to avoid any unpredictable damag...

Page 12: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved XT ENG XT24 V1 P120924 ...