-16-
13. Specification
2) Door Lock Controlled with External
Power
1.The external power supply must be used
according to the lock.
2.The inside relay contact is restricted to
230Vac 1A or 24Vdc 1A.
3.The jumper must be taken off before
connecting.
4.Setup the
Unlock Mode
according to
different lock types.
• Power-on-to-unlock type:Unlock
Mode=0(by default)
• Power-off-to-unlock type:Unlock
Mode=1
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER
SUPPLY
Power supply: 26Vdc
Power Consumption Of Outdoor Station: 0.85W in standby;
3.25W in working.
Power Consumption Of Indoor Unit: 0.17W in standby;
6.2W in working.
Camera lens:
Color CMOS, 2.0 Mega pixel
1/2.7’’ fisheye camera,1700 wide angle
Unlock Power output: 12Vdc,250mA
Unlock timing: 1~99s
Working temperature: - 20ºC ~ +55ºC
Wiring: 2 wire, non-polarity
Dimension: 5.51(H)×8.66(W)×0.69(D)inch(Indoor Unit)
6.93(H)×3.54(W)×1.06(D)inch(surface)
8.66(H)×4.68(W)×2.05(D)inch(flush)
* DT-RLC relay actuator is needed for 2nd lock connection.