Electric Lock Connection
Lock Controlled with Internal Power
Lock can be powered from Door Station if:
The
lock
is
‘
Power-on-to-unlock
’
The
lock is 12V, and holding current
is
less
than 250mA
‘Unlocking Mode’
paramenter would be 0
(default, no need extra programming)
EB
*
LOCK
PL
S+
S-
Electric lock, the jumper position in 2-3
1 2 3
BUS
M
agnetic lock, the jumper position in 1-2
1 2 3
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be
used according to the lock
2. The jumper must be taken off
before connecting
3. Setup the
Unlock Mode
of Monitor
for different lock types
•
Power-on-to-unlock type:Unlock
Mode=0 (by default)
•
Power-off-to-unlock type:Unlock
Mode=1
LOCK
Take off the Jumper
POWER
SUPPLY
BUS
PL
S+