background image

Declaration of Conformity

CE-Conformity

This product has been developed and manufactured in accordance with the 

current European standards and guidelines.
Note: A Declaration of Conformity can be requested separately.

General

The Inclination Sensor 6220312 is an instrument used to control the inclination 

angle of a reference axis.

The product should be examined for any possible damage that may have 

occurred during transportation. Should any damage have occurred, please 

contact the transportation company or 2E mechatronic without delay.
Read the instructions carefully. Familiarize yourself with the device before as-

sembling, installing and operating.
The following assembly and operation instructions have been carefully drafted, 

however, it is not possible to cover every conceivable eventuality. Therefore, if 

you have any queries regarding the product or its application we can be con-

tacted at our internet address (www.2E-mechatronic.de) or one of our contact 

personnel for further information.
The Sensor should be operated and installed in accordance with the instruc-

tions given in order to guarantee that the device and the connected systems 

operate safely.
The safety of operating personnel can only be guaranteed when the device is 

used for the purpose which it was intended for. 
Furthermore the national regulations are to be followed. (e.g. VDE0100)
Only shielded cables have to be used for connecting the device.

Page 2  |  Instruction Manual  6220312  |  2E mechatronic 

Page 3  |  Instruction Manual  6220312  |  2E mechatronic 

Page 4  |  Instruction Manual  6220312  |  2E mechatronic 

Summary of Contents for 6220312

Page 1: ... 0 7021 9301 70 Mail info 2E mechatronic de Web www 2E mechatronic de s t e p h a n h u t t e n l o c h e r Produktmanager Product Manager 2E mechatronic GmbH Co KG Mikrosysteme für die Industrie Maria Merian Straße 29 D 73230 Kirchheim T Tel 49 0 70 21 93 01 26 Fax 70 E Mail s huttenlocher 2e mechatronic de www 2e mechatronic de n a r r g r o u p 2E VK 08 12 RZ 27 09 12 16 02 Seite ...

Page 2: ... 6220312 1 Declaration of Conformity 3 CE Conformity 3 General 3 Technical Data 4 Installation Assembly 4 5 Safety Instructions 6 Electrical Connector 6 Operation 7 Service 8 Page 2 Instruction Manual 6220312 2E mechatronic ...

Page 3: ...lling and operating The following assembly and operation instructions have been carefully drafted however it is not possible to cover every conceivable eventuality Therefore if you have any queries regarding the product or its application we can be con tacted at our internet address www 2E mechatronic de or one of our contact personnel for further information The Sensor should be operated and inst...

Page 4: ...s mount the Sensor using 2 head shoulder screws fitting an inner diameter of Ø5H7 Page 4 Instruction Manual 6220312 2E mechatronic Technical Data Axis 1 Positive sense of rotation Clockwise Measurement range angle 360 or custom spezific Resolution 14 bit 0 022 FS Dimensions 79 mm x 28 mm x 21 mm Operating voltage 10V 30V Measurement rate 180 ms Protection class IP67 Temperature range operating and...

Page 5: ...Page 5 Instruction Manual 6220312 2E mechatronic Fixing Point Variation 2 Fixing Point Variation 1 ...

Page 6: ...ponsibility for safe planning assembly operating and maintenance lies with the equipment user The installation and operation of all devices should only be carried out by qualified personnel Changes or modifications which are not expressly approved in the operation manual and are made without permission could void the warranty and manufacturer s liability Should a severe disturbance occur the devic...

Page 7: ... an analogue current interface 4 20mA Connect Pin 1 with Vcc and Pin 3 with GND COM PIN 2 is either not connected n c or connected with PIN1 Between I SIG out Pin 4 and GND Pin 3 the output signal can be measured The current limits for the output signal are 3 8mA and 20 2mA apart case of error In case of error check first the pin configuration Supply Voltage apparent ohmic resistance Generally 9V ...

Page 8: ...The Sensor is maintenance free Should a fault occur please contact the following 2E mechatronic GmbH Co KG Maria Merian Str 29 D 73230 Kirchheim Teck Phone 49 0 7021 9301 0 Fax 49 0 7021 9301 70 Mail info 2E mechatronic de Web www 2E mechatronic de 16 10 2013 ...