9/6/2006 

4.5 Maintaining the O-ring Seal:  

 

If the main body to lid O-ring is not installed, install the O-ring before diving. This is 

the only user serviceable O-ring.    Its care and maintenance  are critical to the watertight 
integrity of the housing. The O-ring should be replaced at the service interval (see section on 

service). If the O-ring is contaminated, or not already installed, inspect, grease and install the 

O-ring according to the following guidelines. 

 

 
4.6 Inspection, cleaning and re-instillation of the O-ring 
 

Tools:  
 

A soft cotton bud or sponge applicator, make sure these are free of all chemicals or 

contamination such as loose fibers, and the tube of silicone grease supplied with the housing 
are required. Note other types of silicone grease specifically for use with underwater camera 
equipment can usually also be used. It is advised to carry out the following procedure on a 
firm clean level surface, (e.g. at a table), to prevent skidding especially useful to have when 

diving from a boat. 

 

 

 

When to maintain the O-ring seal:  
 

Remove the O-ring periodically for inspection. It is not necessary to remove, clean and 

re-install the O-ring after every dive provided the O-ring did not become contaminated. As a 
rule of thumb set up the camera and housing before a day’s diving. If the housing is required 
to be opened between dives for changing memory card or re-charging batteries, make sure 
the outside of the housing is thoroughly toweled dry before opening up.  After removing the 

lid and servicing the camera, replace the lid straight away, rather than leaving it lying around. 
Before replacing the lid, make sure that no contamination such as dust, hair, salt, sand etc. 
has fallen onto the O-ring or O-ring recess, as a precaution we recommend to inspect the O-

ring every time the lid is opened and to carry out the maintenance if necessary.  

 

Procedure: 

 

 

Place the lid on a firm non-slip level surface.   

 

The O-ring can be extracted using an O-ring extractor tool (make sure the tool has no 
sharp edges).  Alternatively use the flats of the thumbs to gently stretch the O-ring on 
two faces (Fig. 4) thus making a small loop protruding a few mm. The loop can then 

be grasped between finger and thumb, to pull the O-ring over the lip. 

 

Clean the O-ring recess (the square groove where the O-ring sits) with a cotton bud or 
sponge applicator. 

 

Inspect the O-ring all the way round its surface for damage such as cuts tears or 

contamination. This should be done visually and also by feeling the surface texture 
between finger and thumb. 

Summary of Contents for E-500

Page 1: ...9 6 2006 1 Camera Housing Model E 500 Olympus User Manual Contents 1 Introduction 2 Specifications 3 Function Controls 4 Set up Instructions 5 Use Care of Housing 6 Service 7 Warranty ...

Page 2: ...fitted to tailor the housing to your camera model 2 Specifications E 500 Test Pressure 10 Bar 300 ft Housings are individually tested Closure Design Air Lock Body Material Polycarbonate Overall Size 210 x 270 x 200 mm LxWxH Total Weight Approximately 2 46 Kg Housing only Buoyancy with camera Approximately neutral in salt water Features Visible main O ring for final pre dive check Double O ring des...

Page 3: ...watertight seal 4 2 Pressure release plug To open the housing the pressure release plug must be first unscrewed and then pulled out all the way Fig 1 This provides a passage for the air to pass though and eliminate the pressure different between the inside of the housing and the ambient The plug consists of an internal double O ring seal on the stainless steel slide shaft These internal O rings fo...

Page 4: ...ually inspected and hydrostatically tested in the factory The design of the main piston O ring seal is among the most reliable in the industry and the watertight integrity is excellent This special O ring design provides a perfect seal even if there is any movement between the body and lid due to change of ambient pressure However please note that responsibility for ensuring the integrity of the w...

Page 5: ...ve provided the O ring did not become contaminated As a rule of thumb set up the camera and housing before a day s diving If the housing is required to be opened between dives for changing memory card or re charging batteries make sure the outside of the housing is thoroughly toweled dry before opening up After removing the lid and servicing the camera replace the lid straight away rather than lea...

Page 6: ...cap and wrist strap The pressure release plug should be pulled out before inserting the camera Attach the plastic slide tray to the camera s tripod mounting fixture with a coin screwdriver or the end of the universal tool supplied Fig 5 Take care not to excessively tighten the screw Attach the zoom gear guide on the lens zoom bezel with the mounting Velcro Fig 6 pointing the guide right into the s...

Page 7: ...ir cannot escape Squeeze the lid closed all the way with the hissing of expelled air Screw home the pressure release plug There is no need to excessively tighten this plug The seal is made by internal O rings The O ring on the underside of the plug is just to keep out dirt After replacing the lid make a final visual inspection of the main O ring for contamination Fig 11 ...

Page 8: ...e the O ring is in contact with the lid Follow this line all the way round the edge of the seal as a final check that the seal is good The housing is now ready for the dive Important Before diving make sure the pressure release plug is pushed back inside and then screwed home do not over tighten this plug finger tight only ...

Page 9: ...sist of internal double O ring seals on a stainless steel shaft This arrangement is very reliable however as a precaution when operating the controls avoid excessively rapid movements as this may distort the O ring Also please allow for the fact that the camera takes a few seconds to power on If the camera dose not appear to respond to a control action make sure that no other controls are pressing...

Page 10: ...ommended to remove the handle and shutter extension and wrap the camera in foam or bubble wrap 5 5 Accidents The impact resistance of the housing is excellent However after an accident the alignment of the housing may have been damaged Therefore in the event of your housing suffering an impact force e g being dropped it is essential you do not use the housing for diving Please return the housing i...

Page 11: ...lidate warranty Please fill in the information below and return a copy to 10 Bar Underwater Housing at the address below to validate the warranty Copy to be retained by user Housing Type Date of Purchase Serial Number Labelled inside housing Dealer Owner s Name e mail Owner s Address Tel Fax Office Showroom Unit C 2 F Wing Hin Factory Building 31 33 Ng Fong St San Po Kong Hong Kong Tel 852 2573 32...

Page 12: ...f warranty 10 BAR will repair or replace the housing Please note that disassembly of the housing will invalidate warranty Please fill in the information below and return to us at the address below to validate the warranty Housing Type Date of Purchase Serial Number Labelled inside housing Deale Owner s Name e mail Owner s Address Tel Fax Please return the Warranty to the following address Office S...

Reviews: