Page 13
Sample Wiring Diagrams
5 Wire, Single Stage Electric Heat
Residential Electric Heat units with a separately controlled fan.
INSTALLATION INSTRUCTIONS
ELEC
GAS
JP 1
JP 2
JP 3
O
B
HP
GAS
5 Conductor 18 to 22 gauge
unshielded cable from the
thermostat to the equipment.
FAN
G
COMPRESSOR
Y
MODEL
:
S1-TBEU22P7S
MADE IN CHINA
LIS
TED
4Z95
24V
. 60HZ
NEC CLASS 2
C
R
Y1
W1/O/b
G
W2
Y2
ENCLOSED
ENERGY
MAN
AGEMENT
EQUIPMENT
POWER
R
COMMON
C
W
ELECTRIC HEAT
JUMPER SETTINGS
With Demand
1st Stage Cooling
1st Stage Heating
Y, G
W1, G
ACTIVE OUTPUTS
S1-TBEU22P7S