8.3.3 X5 Auxiliary I/O
Pin
Signal
Direction
Description
1
DIGITAL_IN_P
Input
Source of auxiliary Digital Input
2
DIGITAL_IN_N
Input
Sink of auxiliary Digital Input
3
DIGITAL_OUT
Output
Pairing Lamp command
4
DIAG_OUT
Output
Diagnostic Output of safety logic
Parameter
Pin Power Supply Limits Conditon
Min.
Typ.
Max
Differential Input Voltage
1 - 2
Absolute maximum
-
-35 V
-
35 V
Current absorbed by
auxiliary Input
1 - 2 Operating
Over operating temperature range
and voltage ranges
-20 mA
-
20 mA
Input voltage sensed as
“Auxiliary input is OFF”
1 - 2 Operating
-
-32 V
-
5V
Input voltage sensed as
“Auxiliary input is ON”
1 - 2 Operating
-
15 V
-
32 V
Voltage on the Output
in the high impedance
state
4 Operating
-
0 V
-
32 V
DIAG_OUT current
4 Operating
-
0 A
-
0,5 A
Voltage drop between
DIGITAL_OUT and the
supply ground connect-
ed to Pins 1-2 (in the low
impedance state)
3 Operating
At 0,5 A, over operating tempera
-
ture range and voltage
-
-
0,5 V
Leakage current of the
auxiliary output (in the
high impedance state)
3 Operating
Over operating temperature, volt-
age and current ranges
-
-
10 µA