OPERATION AND INSTALLATION MANUAL

 

ISSUE: 1.1 
APPLIES TO THE REGULATOR:  

 

boiler, series: ecoMAX800 (excluding ecoMAX800R1,T1), ecoMAX850, ecoMAX860, ecoMAX910/920 

 

solar: ecoSOL301/400 

 

heat pump, series: ecoTRONIC100/200 

 

ventilation, seria: ecoVENT

 

 
 

INTERNET MODULE

  

ecoNET300 

REMOTE CONTROL OF REGULATORS

 

 

09-2017 

www.econet24.com 

 

ecoNET.apk 

ecoNET.app

 

Summary of Contents for ecoNET300

Page 1: ...OR boiler series ecoMAX800 excluding ecoMAX800R1 T1 ecoMAX850 ecoMAX860 ecoMAX910 920 solar ecoSOL301 400 heat pump series ecoTRONIC100 200 ventilation seria ecoVENT INTERNET MODULE ecoNET300 REMOTE CONTROL OF REGULATORS 09 2017 www econet24 com ecoNET apk ecoNET app ...

Page 2: ......

Page 3: ...RIES 8 6 5 CONNECTION WITH ECOSOL 8 6 6 CONNECTION WITH ECOTRONIC SERIES 8 6 7 CONNECTION WITH ECOVENT SERIES 9 7 CONNECTION WITH INTERNET 9 8 LOGGING TO THE MODULE FROM THE LOCAL LAN 11 9 LOGGING TO ECONET ACCOUNT 11 9 1 FIRST LOGGING TO ECONET ACCOUNT 11 10 WEBSITE SUPPORT 12 10 1 CURRENT DATA 13 10 2 DIAGRAM 13 10 3 USER AND SERVICE PARAMETERS 13 10 4 HEAT YIELD GRAPH 13 10 5 DATA HISTORY 13 10...

Page 4: ... designed and made of materials of highest quality The product meets the requirements of the Directive 2012 19 EU of 4 July 2012 on waste electrical and electronic equipment WEEE according to which it is marked by the symbol of crossed out wheeled bin like below meaning that product is subjected to separate collection Responsibilities after finishing a period of using product dispose of the packag...

Page 5: ...d clear tiles visualization via readable hydraulic diagram indicating current operation of the hydraulic system preview and edition options of most user and service parameters of the regulator registration of operation parameters and alarm conditions of the regulator possibility of e mail notifications concerning alarm conditions of the regulator 4 Safety In any circumstances do not modify constru...

Page 6: ...1 socket for RJ11 ecoLINK2 interface 2 a plug for regulator module transmission socket 3 socket for a control panel plug 6 1 Connection with ecoMAX800 series This chapter applies to ecoMAX800 P1 P2 R2 T2 D1 D2 regulators It is not applicable to ecoMAX800R1 and ecoMAX800T1 In case of ecoMAX800 series a EL2adapter or El2adapter v2 must be used in order to connect ecoLINK2 6 2 Connection with ecoMAX8...

Page 7: ...divider RJ11 telephone divider 1 connection of RJ11 ecoLINK2 interface plug 2 connection of the control panel plug 3 connection of an additional cable with two RJ11 terminals Standard RJ11 telephone cable with an option of connecting wires and a method of connecting into the divider Below show location of the regulator COM transmission socket where interface ecoLINK2 on diagram includes COM transm...

Page 8: ...ed directly to the regulator s RJ11 socket 6 5 Connection with ecoSOL In case of ecoSOL301 400 500 series the ecoLINK2 interface must be connected directly to the regulator s RJ11 socket 6 6 Connection with ecoTRONIC series In case of ecoTRONIC100 200 series a El2adapter v2 must be used in order to connect ecoLINK2 interface ...

Page 9: ...lug to a mini USB Port socket and 3G USB Port to the ecoLINK2 interface Connect with RJ45 Ethernet Port with Ethernet cable e g with ADSL router switch and modem A socket does not have to be use in case of Wi Fi wireless network access The Mode Switch can be set in any position Connection of ecoNET300 with ETHERNET RJ45 with access points of LAN wire Internet network or with Wi Fi wireless network...

Page 10: ...er connection condition can be checked It is required to save the displayed IP number e g IP 10 1 2 237 This number in a form of http 10 1 2 237 is entered into the address field from the level of LAN network A website to operate the regulator menu will be activated It is necessary to enter network parameters in General settings menu of the control panel in order to make a wireless connection via ...

Page 11: ...coNET Ethernet or ecoNET WiFi Activated page will ask for user and password Default settings are User admin Password admin After correct login a WWW page for managing the regulator operation will be displayed 9 Logging to ecoNET account The ecoNET300 internet module cooperates with external server which is available under www econet24 com This provides access to the regulator via Internet In order...

Page 12: ...d e mail address Obligatory fields E mail Password Password again Creating an ecoNET account will only be possible after you have read the Terms of Use in the form of regulations Press the Register button 10 Website support Description of the Web page menu for managing the work of the regulator Current data Current readout of the regulator operation condition data and possibility of changing its s...

Page 13: ...without saving a new setting is possible by clicking on the symbol 10 3 User and service parameters The basic parameters of the regulator work are displayed in the User parameters tab and can be modified by the user Advanced parameters are displayed in the Service parameters tab and can only be modified after entering a service password All displayed parameters are grouped accordingly Click on the...

Page 14: ...registered alarms and other events sent by the regulator a type of alarm event and period of its occurrence is displayed Log into www econet24 com external server in order to display all logs of alarm conditions from the beginning of operation of the controller Logging into a local LAN network gives a possibility to see only 100 newest logs Alarm notices can be sent on e mail It enables the user t...

Page 15: ...Fi network read the Wi Fi signal strength and the quality of his signal display information about ecoNET24 server its status and availability After pressing Check server availability button user can check if the external server is available from a level of Internet browser excluding ecoNET300 Internet module read information concerning selected controller identifier UID number software version in ...

Page 16: ...ser name and password Default username and password user admin password admin can be restored with the use of WPS RESET button located near indicators on the ecoNET300 housing The ecoNET300 module has to be connected to power supply 1 Push WPS RESET button during normal module operation 2 Hold this button pressed for at least 10 seconds 3 Release the WPS RESET button 4 A LED indicator near the but...

Page 17: ...17 7 Default username and password will be restored user admin password admin ...