Page 1: ... JW Series Computer Link SIO Driver 1 System Configuration 3 2 Selection of External Device 8 3 Example of Communication Setting 9 4 Setup Items 45 5 Cable Diagram 50 6 Supported Device 79 7 Device Code and Address Code 83 8 Error Messages 87 ...

Page 2: ...vice Select a model series of the External Device to be connected and connection method 2 Selection of External Device page 8 3 Example of Communication Settings This section shows setting examples for communicating between the Display and the External Device 3 Example of Communication Setting page 9 4 Setup Items This section describes communication setup items on the Display Set communication se...

Page 3: ... Example 4 page 15 Cable Dia gram 4 page 60 JW 21CM 1 RS422 485 4wire Setting Example 1 page 9 Cable Diagram 1 page 50 RS422 485 2wire Setting Example 2 page 11 Cable Diagram 2 page 54 JW30H JW 31CUH1 JW 21CM 1 RS422 485 4wire Setting Example 1 page 9 Cable Dia gram 1 page 50 RS422 485 2wire Setting Example 2 page 11 Cable Diagram 2 page 54 JW 32CUH1 JW 32CUM1 JW 32CUM2 JW 33CUH1 JW 33CUH2 JW 33CU...

Page 4: ... unit RS232C Setting Example 10 page 27 Cable Diagram 3 page 59 RS422 485 4wire Setting Example 11 page 29 Cable Diagram 7 page 69 JW 10CM RS422 485 4wire Setting Example 8 page 23 Cable Diagram 1 page 50 RS422 485 2wire Setting Example 9 page 25 Cable Diagram 2 page 54 JW10 JW 1324K JW 1424K JW 1624K JW 1342K JW 1442K JW 1642K Communication port on the base module RS422 485 2wire Setting Example ...

Page 5: ...S232C Setting Example 13 page 33 Cable Diagram 9 page 78 RS422 485 4wire Setting Example 14 page 35 Cable Diagram 5 page 64 PG COMM2 on the CPU unit RS232C Setting Example 15 page 37 Cable Diagram 6 page 68 RS422 485 4wire Setting Example 16 page 39 Cable Diagram 5 page 64 JW 21CM 2 RS422 485 4wire Setting Example 17 page 41 Cable Diagram 1 page 50 RS422 485 2wire Setting Example 18 page 43 Cable ...

Page 6: ... 3650A PS 3651A COM1 1 PS 3700A Pentium 4 M PS 3710A COM1 1 COM2 1 COM3 2 COM4 2 It is necessary to set up the SIO type with the Dip switch Please set up as follows according to SIO type to be used COM3 2 COM3 2 PS 3711A COM1 1 COM2 2 COM2 2 COM2 2 Dip switch Setting Description 1 OFF Reserve always OFF 2 OFF SIO type RS 232C 3 OFF 4 OFF Output mode of SD TXD data Always output 5 OFF Terminal resi...

Page 7: ... insertion to RD RXD None 7 OFF Short circuit of SDA TXA and RDA RXA Does not Exist 8 OFF Short circuit of SDB TXB and RDB RXB Does not Exist 9 OFF RS RTS Auto control mode Disable 10 OFF Dip switch Setting Description 1 OFF Reserve always OFF 2 ON SIO type RS 422 485 3 ON 4 OFF Output mode of SD TXD data Always output 5 OFF Terminal resistance 220Ω insertion to SD TXD None 6 OFF Terminal resistan...

Page 8: ...guration page 3 Use System Area Check this option when you synchronize the system data area of the Display and the device memory of the External Device When synchronized you can use the ladder program of the External Device to switch the display or display the window on the Display Cf GP Pro EXReference Manual Appendix 1 4 LS Area only for direct access method This can be also set with GP Pro EX o...

Page 9: ...nal Device recommended by Digital Electronics Corp are shown 3 1 Setting Example 1 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 10: ...witch Setting Value Setup Description SW2 x10 0 Station No setting Set the upper station number SW1 x1 1 Station No setting Set the lower station number Set the station No between 01 and 37 o with SW2 and SW1 DIP Switch Setting Value Setup Description SW3 1 OFF Reserved SW3 2 ON Number of communication wire 4 wire SW3 3 OFF Reserved SW3 4 ON Parity Even Rotary Switch Setting Value Setup Descriptio...

Page 11: ...e 2 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 12: ...Switch Setting Value Setup Description SW2 x10 0 Station No setting Set the upper station number SW1 x1 1 Station No setting Set the lower station number Set the station No between 01 and 37 o with SW2 and SW1 DIP Switch Setting Value Setup Description SW3 1 OFF Reserved SW3 2 OFF Number of communication wire 2 wire SW3 3 OFF Reserved SW3 4 ON Parity Even Rotary Switch Setting Value Setup Descript...

Page 13: ...e 3 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 14: ...ting to enable the setting Setting for 236 Description for Bit Setting for 237 Setting Area Setting Value Setup Description 236 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop bit 2 bits D6 OFF Always OFF D7 OFF Always OFF Setti...

Page 15: ...e 4 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 16: ...g Area Setting Value Setup Description 236 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop bit 2 bits D6 OFF Always OFF D7 OFF Always OFF Setting Area Setting Value Setup Description 237 1 o Station No setting Enter in octal num...

Page 17: ...e 5 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 18: ...ting to enable the setting Setting for 234 Description for Bit Setting for 235 Setting Area Setting Value Setup Description 234 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop Bit 2 bits D6 OFF Always OFF D7 OFF Always OFF Setti...

Page 19: ...e 6 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 20: ...ting to enable the setting Setting for 236 Description for Bit Setting for 237 Setting Area Setting Value Setup Description 236 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop Bit 2 bits D6 OFF Always OFF D7 OFF Always OFF Setti...

Page 21: ...e 7 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 22: ...ting to enable the setting Setting for 236 Description for Bit Setting for 237 Setting Area Setting Value Setup Description 236 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop Bit 2 bits D6 OFF Always OFF D7 OFF Always OFF Setti...

Page 23: ...e 8 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 24: ...etup Description SW0 4 SIO Type Computer link Rotary Switch Setting Value Setup Description SW2 0 Station No setting Set the upper station number SW1 1 Station No setting Set the lower station number Set the station No between 01 and 37 o with SW2 and SW1 DIP Switch Setting Value Setup Description SW3 1 OFF Reserved SW3 2 ON Number of communication wire 4 wire SW3 3 OFF Reserved SW3 4 ON Parity Ev...

Page 25: ...e 9 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 26: ...tup Description SW0 4 SIO Type Computer link Rotary Switch Setting Value Setup Description SW2 0 Station No setting Set the upper station number SW1 1 Station No setting Set the lower station number Set the station No between 01 and 37 o with SW2 and SW1 DIP Switch Setting Value Setup Description SW3 1 OFF Reserved SW3 2 OFF Number of communication wire 2 wire SW3 3 OFF Reserved SW3 4 ON Parity Ev...

Page 27: ...e 10 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 28: ...ng to enable the setting Setting for 0236 Description for Bit Setting for 0237 Setting Area Setting Value Setup Description 0236 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop Bit 2 bits D6 OFF Always OFF D7 OFF Always OFF Sett...

Page 29: ...e 11 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 30: ...tance Switch Insert the termination resistance at the end Connecting the 6th and 13th pins in the port on the External Device allows the termination resistance to be inserted Setting Area Setting Value Setup Description 0236 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OF...

Page 31: ...e 12 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 32: ...0 H Communication mode setting Computer link Setting Area Setting Value Setup Description 236 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop Bit 2 bits D6 OFF Always OFF D7 OFF Data Length 7 bits Setting Area Setting Value Setu...

Page 33: ...e 13 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 34: ...o enable the setting Setting for 0234 Description for Bit Setting for 0235 Setting Area Setting Value Setup Description 0234 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop Bit 2 bits D6 OFF Data Length 7 bits D7 OFF Always OFF ...

Page 35: ...e 14 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 36: ...o enable the setting Setting for 0234 Description for Bit Setting for 0235 Setting Area Setting Value Setup Description 0234 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop Bit 2 bits D6 OFF Data Length 7 bits D7 OFF Always OFF ...

Page 37: ...e 15 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 38: ...o enable the setting Setting for 0236 Description for Bit Setting for 0237 Setting Area Setting Value Setup Description 0236 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop Bit 2 bits D6 OFF Data Length 7 bits D7 OFF Always OFF ...

Page 39: ...e 16 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 40: ...o enable the setting Setting for 0236 Description for Bit Setting for 0237 Setting Area Setting Value Setup Description 0236 30 H Communication setting Enter in hex number Description for each bit is shown below Bit in System Area Setting Value Setup Description D0 OFF Transfer Speed 19200 bps D1 OFF D2 OFF D3 OFF Parity Even D4 ON D5 ON Stop Bit 2 bits D6 OFF Data Length 7 bits D7 OFF Always OFF ...

Page 41: ...e 17 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 42: ...witch Setting Value Setup Description SW2 x10 0 Station No setting Set the upper station number SW1 x1 1 Station No setting Set the lower station number Set the station No between 01 and 37 o with SW2 and SW1 DIP Switch Setting Value Setup Description SW3 1 OFF Reserved SW3 2 ON Number of communication wire 4 wire SW3 3 OFF Reserved SW3 4 ON Parity Even Rotary Switch Setting Value Setup Descriptio...

Page 43: ...e 18 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Page 44: ...Switch Setting Value Setup Description SW2 x10 0 Station No setting Set the upper station number SW1 x1 1 Station No setting Set the lower station number Set the station No between 01 and 37 o with SW2 and SW1 DIP Switch Setting Value Setup Description SW3 1 OFF Reserved SW3 2 OFF Number of communication wire 2 wire SW3 3 OFF Reserved SW3 4 ON Parity Even Rotary Switch Setting Value Setup Descript...

Page 45: ...select Device PLC Settings from System setting window in workspace Setup Items Setup Description SIO Type Select the SIO type to communicate with the External Device Speed Select speed between the External Device and the Display Data Length Select data length Parity Select how to check parity Stop Bit Select stop bit length Flow Control Select the communication control method to prevent overflow o...

Page 46: ...ice use an integer from 0 to 255 to enter how many times the Display retransmits the command Wait To Send Use an integer from 0 to 255 to enter standby time ms for the Display from receiving packets to transmitting next commands RI VCC Switches RI VCC of the 9th pin It is necessary to change RI 5V by changeover switch of IPC when connect with IPC Please refer to the manual of the IPC for more deta...

Page 47: ... Setup Description SIO Type Select the SIO type to communicate with the External Device To make the communication settings correctly confirm the serial interface specifications of Display unit for SIO Type We cannot guarantee the operation if a communication type that the serial interface does not support is specified For details concerning the serial interface specifications refer to the manual f...

Page 48: ...onse from the External Device use an integer from 0 to 255 to enter how many times the Display retransmits the command Wait To Send Use an integer from 0 to 255 to enter standby time ms for the Display from receiving packets to transmitting next commands Setup Items Setup Description Device PLC Name Select the External Device to set Device name is a title of the External Device set with GP Pro EX ...

Page 49: ... Settings from Peripheral Equipment Settings Touch the External Device you want to set from the displayed list and touch Option Setup Items Setup Description RI VCC Switches RI VCC of the 9th pin It is necessary to change RI 5V by changeover switch of IPC when connect with IPC Please refer to the manual of the IPC for more detail ...

Page 50: ...tem not to form short circuit loop Connect the isolation unit when communication is not stabilized under the influence of a noise etc Cable Diagram 1 Display Connection Port Cable Remarks GP 1 COM1 AGP 3302B COM2 IPC 2 1 All GP models except AGP 3302B 2 Only the COM port which can communicate by RS 422 485 4 wire can be used COM Port of IPC page 6 A COM port conversion adapter by Pro face CA3 ADPC...

Page 51: ... Signal name Your own cable Shield External Device Terminal block Signal name Shield RDB SDB SG FG CA3 ADPCOM 01 CA3 ADPTRM 01 220 1 4W RDA SDA L1 L2 L3 L4 FG 220 1 4W SW7 OFF L1 L2 L3 L4 FG SW7 ON Display Terminal resistance Ω Signal name Ω Terminal resistance Your own cable Shield External Device Terminal block Signal name Shield Shield External Device Terminal block Signal name Shield L1 L2 L3 ...

Page 52: ...Pin Shell Shield External Device Terminal block Signal name Shield Shield External Device Terminal block Signal name Shield RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 RDA SDA L1 L2 L3 L4 FG SW7 ON Display 220 1 4W Terminal resistance Ω 220 1 4W Ω Terminal resistance Signal name Your own cable Shield External Device Terminal block Signal name Shield RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 RDA SDA ...

Page 53: ...resistance D Sub 9 pin plug Pin Signal name Shell Shield Terminal block Signal name External Device 220 Ω 1 4W Termination resistance Shield Your own cable CA4 ADPONL 01 L1 L2 L3 L4 FG RDB 7 RDA 2 SDB 8 5 SG SDA FG 3 TERMRX 1 TERMTX 9 SW7 OFF L1 L2 L3 L4 FG SW7 ON Display Terminal block Signal name Shield D Sub 9 pin plug Pin Signal name Shell Your own cable External Device 220 1 4W Terminal resis...

Page 54: ...length 1000m or less B Your own cable GP 2 COM2 2 All GP models except GP 3200 series and AGP 3302B C Online adapter by Pro face CA4 ADPONL 01 Terminal block conversion adapter by Pro face CA3 ADPTRM 01 Your own cable D Online adapter by Pro face CA4 ADPONL 01 Your own cable IPC 3 3 Only the COM port which can communicate by RS 422 485 2 wire can be used COM Port of IPC page 6 E COM port conversio...

Page 55: ...l resistance Ω Signal name Shield Your own cable External Device Terminal block Signal name Shield RDB SDB SG FG CA3 ADPCOM 01 CA3 ADPTRM 01 RDA SDA L3 L4 L1 L2 FG L3 L4 L1 L2 FG SW7 OFF SW7 ON Display 220 1 4W Terminal resistance Ω Signal name Shield Your own cable External Device Terminal block Signal name Shield External Device Terminal block Signal name Shield Shield SDA 3 RDB 2 SG 5 4 ERA SDB...

Page 56: ...cket Pin Signal name Shell Shield Terminal block Signal name External Device Shield Shield Terminal block Signal name External Device Shield RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 RDA SDA L3 L4 L1 L2 FG SW7 ON Display 220 1 4W Terminal resistance Ω Signal name Your own cable Shield External Device Terminal block Signal name Shield RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 RDA SDA L3 L4 L1 L2 FG...

Page 57: ... Display 220 1 4W Terminal resistance Ω Signal name Pin Shell Shield External Device Terminal block Signal name Shield Your own cable CA4 ADPONL 01 RDB 7 RDA 2 SDB 8 5 SG SDA FG 3 TERMRX 1 TERMTX 9 L3 L4 L1 L2 FG SW7 OFF L3 L4 L1 L2 FG SW7 ON D Sub 9 pin plug Display 220 1 4W Terminal resistance Ω Signal name Pin Shell Shield External Device Terminal block Signal name Shield Your own cable Shield ...

Page 58: ...ernal Device Terminal block Signal name Shield L3 L4 NC 3 DATA 2 GND SG 5 NC 7 ERA 4 CSA 8 FG DATA 1 L1 L2 FG SW7 ON Display 220 Ω 1 4W Termination resistance D Sub 9 pin socket Pin Signal name Shell Shield Terminal block Signal name External Device Shield L3 L4 ERB 9 CSB 6 NC 3 DATA 2 GND SG 5 NC 7 ERA 4 CSA 8 FG DATA 1 L1 L2 FG SW7 OFF SW7 ON Display 220 Ω 1 4W Termination resistance D Sub 9 pin...

Page 59: ... IPC 1 1 Only the COM port which can communicate by RS 232C can be used COM Port of IPC page 6 Your own cable Cable length 15m or less ER DTR 4 SD TXD 3 CS CTS 8 6 DR DSR SG 5 FG RD RXD 2 RS RTS 7 CTS 5 RD 3 RTS 4 12 SG 7 FG SD 2 14 1 D Sub 9 pin socket Display Signal name Pin Shell Shield External Device D Sub 15 pin plug Signal name Pin ...

Page 60: ... 6 A COM port conversion adapter by Pro face CA3 ADPCOM 01 Terminal block conversion adapter by Pro face CA3 ADPTRM 01 Your own cable Cable length or less B Your own cable GP 3 COM2 3 All GP models except GP 3200 series and AGP 3302B C Online adapter by Pro face CA4 ADPONL 01 Terminal block conversion adapter by Pro face CA3 ADPTRM 01 Your own cable D Online adapter by Pro face CA4 ADPONL 01 Your ...

Page 61: ...ce D Sub 15 pin plug Signal name Pin SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 10 11 12 SD SD RD 13 RD 1 FG SW1 ON D Sub 9 pin socket Display 220 1 4W Terminal resistance Ω 220 1 4W Ω Terminal resistance Signal name Pin Shell Shield External Device D Sub 15 pin plug Signal name Pin SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 10 11 12 SD SD RD 13 RD 1 FG SW1 OFF 10 11 12 S...

Page 62: ...Sub 15 pin plug Signal name Pin Your own cable 220 1 4W Terminal resistance Ω RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 RDA SDA 10 11 12 SD SD RD 13 RD 1 FG SW1 OFF 10 11 12 SD SD RD 13 RD 1 FG SW1 ON Display 220 1 4W Terminal resistance Ω Signal name Shield External Device D Sub 15 pin plug Signal name Pin Your own cable 220 1 4W Terminal resistance Ω Shield External Device D Sub 15 pin plug Sign...

Page 63: ... FG 3 TERMRX 1 TERMTX 9 10 11 12 SD SD RD 13 RD 1 FG SW1 OFF 10 11 12 SD SD RD 13 RD 1 FG SW1 ON D Sub 9 pin plug Display 220 1 4W Terminal resistance Ω 220 1 4W Ω Terminal resistance Signal name Pin Shell Shield External Device D Sub 15 pin plug Signal name Pin Shield External Device D Sub 15 pin plug Signal name Pin Your own cable ...

Page 64: ...ro face CA3 ADPCOM 01 Terminal block conversion adapter by Pro face CA3 ADPTRM 01 Your own cable Cable length 1000m or less B Your own cable GP 3 COM2 3 All GP models except GP 3200 series and AGP 3302B C Online adapter by Pro face CA4 ADPONL 01 Terminal block conversion adapter by Pro face CA3 ADPTRM 01 Your own cable D Online adapter by Pro face CA4 ADPONL 01 Your own cable Do not connect anythi...

Page 65: ...SD SD RD 10 RD 1 FG Display Signal name Shield External Device D Sub 15 pin plug Signal name Pin Your own cable RDB SDB SG FG CA3 ADPCOM 01 CA3 ADPTRM 01 RDA SDA 3 11 9 SD SD RD 10 RD 1 FG 3 11 9 SD SD RD 10 RD 1 FG Display Signal name Shield External Device D Sub 15 pin plug Signal name Pin Your own cable Shield External Device D Sub 15 pin plug Signal name Pin SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 ...

Page 66: ... socket Display Signal name Pin Shell Shield External Device D Sub 15 pin plug Signal name Pin Shield External Device D Sub 15 pin plug Signal name Pin RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 RDA SDA 3 11 9 SD SD RD 10 RD 1 FG Display Signal name Shield External Device D Sub 15 pin plug Signal name Pin Your own cable RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 RDA SDA 3 11 9 SD SD RD 10 RD 1 FG 3 ...

Page 67: ...TX 9 3 11 9 SD SD RD 10 RD 1 FG D Sub 9 pin plug Display Signal name Pin Shell Shield External Device D Sub 15 pin plug Signal name Pin Your own cable CA4 ADPONL 01 RDB 7 RDA 2 SDB 8 5 SG SDA FG 3 TERMRX 1 TERMTX 9 3 11 9 SD SD RD 10 RD 1 FG 3 11 9 SD SD RD 10 RD 1 FG D Sub 9 pin plug Display Signal name Pin Shell Shield External Device D Sub 15 pin plug Signal name Pin Your own cable Shield Exter...

Page 68: ...M1 IPC 1 1 Only the COM port which can communicate by RS 232C can be used COM Port of IPC page 6 Your own cable Cable length 15m or less ER DTR 4 SD TXD 3 CS CTS 8 6 DR DSR SG 5 FG RD RXD 2 RS RTS 7 CTS 12 RD 4 RTS 8 SG 7 FG SD 2 1 D Sub 9 pin socket Display Signal name Pin Shell Shield External Device D Sub 15 pin plug Signal name Pin ...

Page 69: ...f IPC page 6 A COM port conversion adapter by Pro face CA3 ADPCOM 01 Terminal block conversion adapter by Pro face CA3 ADPTRM 01 Your own cable Cable length 1000m or less B Your own cable GP 3 COM2 3 All GP models except GP 3200 series and AGP 3302B C Online adapter by Pro face CA4 ADPONL 01 Terminal block conversion adapter by Pro face CA3 ADPTRM 01 Your own cable D Online adapter by Pro face CA4...

Page 70: ...Device D Sub 15 pin plug Signal name Pin TERM TERM SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 10 11 12 TxD TxD RxD 13 RxD 1 FG 6 D Sub 9 pin socket Display 220 1 4W Terminal resistance Ω Signal name Pin Shell Shield External Device D Sub 15 pin plug Signal name Pin TERM SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 10 11 12 TxD TxD RxD 13 RxD 1 FG 6 10 11 12 TxD TxD RxD 13 R...

Page 71: ... Signal name Shield External Device D Sub 15 pin plug Signal name Pin Your own cable TERM RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 RDA SDA 10 11 12 TxD TxD RxD 13 RxD 1 FG 6 10 11 12 TxD TxD RxD 13 RxD 1 FG 6 Display 220 1 4W Terminal resistance Ω Signal name Shield External Device D Sub 15 pin plug Signal name Pin Your own cable Shield External Device D Sub 15 pin plug Signal name Pin TERM TERM ...

Page 72: ...B 8 5 SG SDA FG 3 TERMRX 1 TERMTX 9 10 11 12 TxD TxD RxD 13 RxD 1 FG 6 10 11 12 TxD TxD RxD 13 RxD 1 FG 6 D Sub 9 pin plug Display 220 1 4W Terminal resistance Ω Signal name Pin Shell Shield External Device D Sub 15 pin plug Signal name Pin Your own cable Shield External Device D Sub 15 pin plug Signal name Pin TERM TERM ...

Page 73: ...length 1000m or less B Your own cable GP 2 COM2 2 All GP models except GP 3200 series and AGP 3302B C Online adapter by Pro face CA4 ADPONL 01 Terminal block conversion adapter by Pro face CA3 ADPTRM 01 Your own cable D Online adapter by Pro face CA4 ADPONL 01 Your own cable IPC 3 3 Only the COM port which can communicate by RS 422 485 2 wire can be used COM Port of IPC page 6 E COM port conversio...

Page 74: ...A3 ADPCOM 01 CA3 ADPTRM 01 RDA SDA L1 L2 Display Signal name Your own cable Shield External Device Terminal block Signal name Shield RDB SDB SG FG CA3 ADPCOM 01 CA3 ADPTRM 01 RDA SDA L1 L2 L1 L2 Display Signal name Your own cable Shield External Device Terminal block Signal name Shield Shield External Device Terminal block Signal name Shield L1 L2 SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 ...

Page 75: ...Display D Sub 9 pin socket Pin Signal name Shell Shield Terminal block Signal name External Device Shield Shield Terminal block Signal name External Device Shield RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 RDA SDA L1 L2 Display Signal name Your own cable Shield External Device Terminal block Signal name Shield RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 RDA SDA L1 L2 L1 L2 Display Signal name Your ow...

Page 76: ... 7 RDA 2 SDB 8 5 SG SDA FG 3 TERMRX 1 TERMTX 9 D Sub 9 pin plug Display Signal name Pin Shell Shield External Device Terminal block Signal name Shield Your own cable L1 L2 CA4 ADPONL 01 RDB 7 RDA 2 SDB 8 5 SG SDA FG 3 TERMRX 1 TERMTX 9 L1 L2 D Sub 9 pin plug Display Signal name Pin Shell Shield External Device Terminal block Signal name Your own cable Shield Shield External Device Terminal block S...

Page 77: ...nal name Shield L1 L2 Shield External Device Terminal block Signal name Shield L1 L2 NC 3 DATA 2 GND SG 5 NC 7 ERA 4 CSA 8 FG DATA 1 Display D Sub 9 pin socket Pin Signal name Shell Shield Terminal block Signal name External Device Shield ERB 9 CSB 6 L1 L2 NC 3 DATA 2 GND SG 5 NC 7 ERA 4 CSA 8 FG DATA 1 Display D Sub 9 pin socket Pin Signal name Shell Shield Terminal block Signal name External Dev...

Page 78: ...s GP COM1 IPC 1 1 Only the COM port which can communicate by RS 232C can be used COM Port of IPC page 6 Your own cable Cable length 15m or less Signal name SG 5 SD TXD 3 CS CTS 8 6 DR DSR ER DTR 4 FG RD RXD 2 RS RTS 7 D Sub 9 pin socket Pin Shell Signal name RD 4 SG 7 FG SD 2 D Sub 15 pin plug External Device Pin 1 Shield Display ...

Page 79: ...ess can be specified as system data area Device Bit Address Word Address 32 bits Remarks Relay 1 0000 0 1577 7 A0000 A1576 0000 1576 2000 0 7577 7 A2000 A7576 2000 7576 Timer Contact T0000 T1777 Counter Contact C0000 C1777 Timer Counter current value 1 B0000 B3776 b0000 b3776 T0000 T3776 Register 09000 09776 19000 19776 29000 29776 39000 39776 49000 49776 59000 59776 69000 69776 79000 79776 89000 ...

Page 80: ...es are used for the word address of the relay and the timer counter current value B in the manual of the External Device For entry use AXXXX or BXXXX 2 File Register consists of the file number and the address Please refer to the GP Pro EX Reference Manual for system data area Cf GP Pro EXReference Manual Appendix 1 4 LS Area only for direct access method Please refer to the precautions on manual ...

Page 81: ... 1 B00000 B37776 TC00000 TC17777 Register 09 19 29 39 49 59 69 79 89 99 09000 09776 19000 19776 89000 89776 99000 99776 Register E0 E1 E2 E3 E4 E5 E6 E7 E0000 E0776 E1000 E1776 E6000 E6776 E7000 E7776 Register 109 389 109000 109776 119000 119776 379000 379776 389000 389776 Register Z Z000 Z377 File Register 1 00000000 1 37777776 System Memory 1 1 The name of system memory is in the External Device...

Page 82: ...on Manual 82 Please refer to the GP Pro EX Reference Manual for system data area Cf GP Pro EXReference Manual Appendix 1 4 LS Area only for direct access method Please refer to the precautions on manual notation for icons in the table Manual Symbols and Terminology ...

Page 83: ... of word address divided by 2 29 0002 Value of word address divided by 2 39 0003 Value of word address divided by 2 49 0004 Value of word address divided by 2 59 0005 Value of word address divided by 2 69 0006 Value of word address divided by 2 79 0007 Value of word address divided by 2 89 0008 Value of word address divided by 2 99 0009 Value of word address divided by 2 E0 000A Value of word addr...

Page 84: ...e of word address divided by 2 F10 0019 Value of word address divided by 2 F11 001A Value of word address divided by 2 F1E 0027 Value of word address divided by 2 F1F 0028 Value of word address divided by 2 F20 0029 Value of word address divided by 2 F21 002A Value of word address divided by 2 F2B 0034 Value of word address divided by 2 F2C 0035 Value of word address divided by 2 Device Device Nam...

Page 85: ... word address divided by 2 49 0004 Value of word address divided by 2 59 0005 Value of word address divided by 2 69 0006 Value of word address divided by 2 79 0007 Value of word address divided by 2 89 0008 Value of word address divided by 2 99 0009 Value of word address divided by 2 Register E0 E1 E2 E3 E4 E5 E6 E7 E0 000A Value of word address divided by 2 E1 000B Value of word address divided b...

Page 86: ...ddress divided by 2 249 004E Value of word address divided by 2 259 004F Value of word address divided by 2 269 0050 Value of word address divided by 2 279 0051 Value of word address divided by 2 289 0052 Value of word address divided by 2 299 0053 Value of word address divided by 2 309 0054 Value of word address divided by 2 319 0055 Value of word address divided by 2 329 0056 Value of word addre...

Page 87: ...sage Displays messages related to the error which occurs Error Occurrence Area Displays IP address or device address of the External Device where error occurs or error codes received from the External Device IP address is displayed such as IP address Decimal MAC address Hex Device address is displayed such as Address Device address Received error codes are displayed such as Decimal Hex Please refe...

Page 88: ...JW Series Computer Link SIO Driver GP Pro EX Device PLC Connection Manual 88 ...