background image

FILE NO.

REFERENCE No.SM5310327

L8CSB/US,XE

NOTE: 1. Parts order must contain model number, part number, and description.

2. Substitute parts may be supplied as the service parts.
3. N.S.P. : Not available as service parts.

Design and specifications are subject to change without notice.

(Product Code : 117 523 55)
(U.S.A., Canada)

VSP-8000

SERVICE MANUAL

System controller

CONTENTS

SPECIFICATIONS .................................................................... 3
1. DISASSEMBLY ..................................................................... 4
2. ADJUSTMENT ...................................................................... 6
3. REWRITING THE SOFTWARE ............................................ 7
4. PARTS LIST ....................................................................... 10
CIRCUIT DIAGRAMS & PRINTED WIRING BOARDS ........... C1

Product safety should be considered when a component replacement is mand in any area of this unit.

Components indicated by the symbol (      ) in the parts list and schematic diagram designate components in which safety can

be of special significance. It is particularly recommended that only parts designated on the parts list in this manual be used for

component replacement designated by the symbol.  No deviations from resistance, wattage or voltage ratings may be made for

replacement items designated by the symbol.

PRODUCT  SAFETY  NOTICE

(Product Code : 117 523 54)
(Europe)

(Taiwan, Korea)

VSP-8000

Summary of Contents for VSP-8000

Page 1: ...4 PARTS LIST 10 CIRCUIT DIAGRAMS PRINTED WIRING BOARDS C1 Product safety should be considered when a component replacement is mand in any area of this unit Components indicated by the symbol in the parts list and schematic diagram designate components in which safety can be of special significance It is particularly recommended that only parts designated on the parts list in this manual be used fo...

Page 2: ... 2 ...

Page 3: ...Multiplexers timelapse VCRs cameras and digital video recorder 128 devices each 64 devices Temparature 0 to 40 C Relative humidity 80 or less Temparature 20 to 60 C Relative humidity 80 or less 12 V DC 4 W 375 W x 55 H x 165 D mm 1 5 kg Communication method Control terminals RS 232C terminal Address termination switch Communication speed baud rate Max no of groups Max no of connected devices Dome ...

Page 4: ... 4 1 2 3 4 4 Bottom Cover Shield Case LCD Assy Cabinet CP 1 BOARD TB 2 BOARD 1 DISASSEMBLY 1 1 REMOVAL OF CABINET AND BOARD LOCATION Fig 1 ...

Page 5: ... 5 CP 1 BOARD TB 1 BOARD TB 2 BOARD TB 3 BOARD LCD OP 1 BOARD OP 2 BOARD Fig 2 Fig 3 2 1 TB 1 BOARD TB 3 BOARD OP 1 BOARD OP 2 BOARD ...

Page 6: ...ENTER button is pushed and indicated with TEST MODE in LCD Adjustment is made again if it is indicated with PLEASE SPIN JST AND PUSH ENTER in LCD 6 The short circuit of the JK405 pin is removed and the test mode is finished 4 JOYSTICK ADJUSTMENT FOR THE ZOOM 1 The pin of JK405 is short circuited and makes the test mode 2 The FUNCTION button and the number 3 button are pushed at the same time and L...

Page 7: ...n Description win dow or enter your name and then click the OK button The Hyper Terminal window appears 4 Click the File F button in the Hyper Terminal window and then click the Properties R button The Properties dialog box appears 5 In the Properties dialog box set Connect using N in Phone Number to Direct to COM and then click the Configure F button The port Setting window of the COM1 Properties...

Page 8: ...NTER button to set to baud rate setting mode The baud rate setting display appears in the system con troller LCD Press the CLEAR button if you want to cancel the opera tion 5 Press the and buttons to select the baud rate setting 6 Press the ENTER button to set to software rewrite standby mode The rewrite standby display appears in the system control ler LCD 3 2 Resetting the computer If an rewriti...

Page 9: ...ears in the system controller LCD Press the ENTER button to the initial display appears in the LCD 9 Turn off the power disconnect the serial cable and then install the panel to the rear of the system controller Table of error code 3 4 RESET button The following three items can be cleared using the RESET button 1 Clock time 2 Password code for security lock cancels the security lock 3 Status list ...

Page 10: ... 6 6 6 6 6 6 6 6 7 8 9 11 12 16 16 16 16 16 16 16 16 16 16 16 17 17 17 17 18 19 20 21 22 82 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 23 23 23 13 14 15 N S P 10 83 83 83 ...

Page 11: ...K 33 645 039 8360 EJECT 34 645 039 8308 REC 35 645 039 8339 STILL 36 645 039 8391 MULTI 37 645 039 8407 QUAD 38 645 053 1507 CAM MPX 39 645 039 8414 PLUS 40 645 039 8445 SEQ 41 645 039 8476 VCR 42 645 053 1521 EXIT BACK 43 645 039 8490 NEXT 44 645 039 8469 LIVE 45 645 039 8483 FULL 46 645 053 1514 MON2 SPOT 47 645 039 8421 STILL 48 645 039 8186 ELS 49 645 039 8193 BLC 50 645 053 1446 PAN 51 645 03...

Page 12: ... DIODE SB10 05P D3002 645 039 7974 DIODE SB05 50P D3003 645 039 7868 DIODE 1SS355 D3004 645 039 7868 DIODE 1SS355 D3005 645 039 7868 DIODE 1SS355 D3006 645 039 7868 DIODE 1SS355 D3007 645 039 7974 DIODE SB05 50P D3008 645 039 7868 DIODE 1SS355 D3009 645 039 7868 DIODE 1SS355 D3010 645 039 7868 DIODE 1SS355 D3011 645 039 7868 DIODE 1SS355 D3012 645 039 7868 DIODE 1SS355 D3013 645 039 7868 DIODE 1SS...

Page 13: ... 645 039 7646 MT GLAZE 1 8W 33KOHM 0 5 R3008 645 039 7646 MT GLAZE 1 8W 33KOHM 0 5 R3009 645 039 7691 MT GLAZE 1 8W 560OHM 0 5 R3010 645 039 7585 MT GLAZE 1 8W 10KOHM 0 5 R3011 645 039 7684 MT GLAZE 1 8W 470KOHM 0 5 R3012 645 039 7592 MT GLAZE 1 8W 10MOHM 0 5 R3013 645 039 7653 MT GLAZE 1 8W 330KOHM 0 5 R3014 645 039 7677 MT GLAZE 1 8W 4 7KOHM 0 5 R3015 645 039 7585 MT GLAZE 1 8W 10KOHM 0 5 R3017 ...

Page 14: ...LE ASSY ACCESSORIES PACKING MATERIALS 613 196 5065 INSTRUCTION MANUAL U S A CANADA 613 196 5058 INSTRUCTION MANUAL EUROPE 645 039 8940 AC ADAPTOR U S A CANADA 645 039 8957 AC ADAPTOR EUROPE 645 053 1712 MODULAR CABLE 645 053 1729 PACKING CASE 645 038 6046 POLY BAG LOCATION PARTS NO DESCRIPTION ...

Page 15: ... CP 1 P W B C6 TB 1 P W B C6 OP 1 P W B C7 OP 2 P W B C7 TB 2 P W B C7 TB 3 P W B C7 PRODUCT SAFETY NOTICE THE COMPONENTS DESIGNATED BY A SYMBOL IN THIS SCHEMATIC DIAGRAM DESIGNATES COMPONENTS WHOSE VALUE ARE OF SPECIAL SIGNIFICANCE TO PRODUCT SAFETY SHOULD ANY COMPONENT DESIGNATED BY A SYMBOL NEED TO BE REPLACED USE ONLY THE PART DESIGNATED IN THE PARTS LIST DO NOT DEVIATE FROM THE RESISTANCE WAT...

Page 16: ...A B C D E F G H I J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 A B C D E F G H I J K C2 OVERALL WIRUNG BLOCK DIAGRAMS OVERALL WIRING TB 1 BOARD ...

Page 17: ...A B C D E F G H I J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 A B C D E F G H I J K C3 CP 1 BOARD ...

Page 18: ...A B C D E F G H I J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 A B C D E F G H I J K C4 OP 1 BOARD ...

Page 19: ...A B C D E F G H I J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 A B C D E F G H I J K C5 OP 2 BOARD TB 3 BOARD TB 2 BOARD ...

Page 20: ...JP3040 JP3038 JP3036 JP3037 JP3039 1 1 1 3 CN309 JP3034 JP3032 JP3033 JP3031 JP3032 JP3030 JP3029 JP3026 JP3023 JP3019 JP3027 JP3024 JP3018 JP3016 JP3028 JP3025 JP3022 JP3020 JP3017 JP3015 JP3021 CN302 1 16 CN303 1 9 TP304 1 JP3013 C3034 X3002 X3001 JP3014 JP3011 C3033 TP302 JP3008 JP3006 C3025 JP3010 JP3006 JP3005 JP3007 C3037 C3026 C3027 C3025 CN301 16 1 TP302 TP305 C3036 VR302 TP301 VR301 JP300...

Page 21: ...3 S1024 S1025 S1028 S1029 S1030 S1031 S1032 S1033 S1034 S1035 S1036 S1037 S1038 S1039 S1040 S1041 S1042 S1043 S1045 S1046 S1048 S1049 S1050 S1051 S1052 S1053 S1019 S1047 S1027 CN102 CN101 JP1028 JP1026 JP1027 JP1025 JP1024 JP1022 JP1023 JP1019 JP1017 JP1021 JP1020 JP1018 JP1016 JP1015 JP1013 JP1014 JP1011 JP1009 JP1012 JP1010 JP1007 JP1006 JP1008 JP1005 JP1003 JP1002 JP1004 JP1001 OP 1 P W B OP 2 ...

Page 22: ...Apr 02 Printed in Japan SANYO Electric Co Ltd Osaka Japan ...