background image

 

 

 

NEC Express Server

 

Express5800 Series

 

Express5800/R320d-E4 

Model Number: N8800-184F, EXP320P

 

 

 

Installation Guide (VMware 5.5) 

30.104.03-103.02 

December 2014 

© NEC Corporation 2014 

 
 

 

 

Express5800/R320d-M4 

Model Number: N8800-185F, EXP320Q

 

 

 

Chapter 1  Installing OS

 

 
Chapter 2  Installing Bundled Software 
 
Chapter 3    Configuring the Separate Log Server 

 
 
 

Summary of Contents for Express 5800 Series

Page 1: ...umber N8800 184F EXP320P Installation Guide VMware 5 5 30 104 03 103 02 December 2014 NEC Corporation 2014 Express5800 R320d M4 Model Number N8800 185F EXP320Q Chapter 1 Installing OS Chapter 2 Installing Bundled Software Chapter 3 Configuring the Separate Log Server ...

Page 2: ... Specifications and other information Installation Guide Chapter 1 Installing OS Installation of OS and drivers and important information for installation Chapter 2 Installing Bundled Software Installation of bundled software such as NEC ESMPRO Chapter 3 Configuring the Separate Log Server Configure the log server using other than ftSys Management Appliance Maintenance Guide Chapter 1 Maintenance ...

Page 3: ...on 25 1 6 Setting HBA configuration by using QLogic 27 1 7 Installing VMware ESXi 35 1 7 1 Installing VMware ESXi 35 1 7 2 Configuring ESXi 38 1 7 3 Configuring the Firewall for the ESXi Host from the vSphere Client 41 1 8 Installing ftSys Management Appliance 42 1 8 1 Checking the Installation Destination Disk 42 1 8 2 Installing ftSys Management Appliance 44 1 9 Installing ft control software 49...

Page 4: ...dress of Log Server or Host Name has been Changed 65 2 3 3 Changing the Firewall Rules on ftSys Management Appliance 66 Chapter 2 Installing Bundled Software 68 1 Bundled Software for the Server 69 1 1 NEC ESMPRO Agent 69 1 1 1 Preinclination 70 1 1 2 Install NEC ESMPRO Agent 71 2 Bundled Software for Management PC 73 2 1 NEC ESMPRO Manager 73 Chapter 3 Configuring the Separate Log Server 74 1 Ste...

Page 5: ... hardware or operating software Tips Indicates information that is helpful to keep in mind when using this server Optical disk drives This server is equipped with one of the following drives depending on the order at the time of purchase These drives are referred to as optical disk drives in this document DVD ROM drive DVD Super MULTI drive Hard disk drives Unless otherwise stated hard disk drive ...

Page 6: ... registered trademarks of LSI Corporation Adobe the Adobe logo and Acrobat are trademarks of Adobe Systems Incorporated DLT and DLTtape are trademarks of Quantum Corporation of the United States PCI Express is a trademark of Peripheral Component Interconnect Special Interest Group Copyright 2010 VMware Inc All rights reserved This product is protected by U S and international copyright and intelle...

Page 7: ...ns Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Industry Canada Class A Emission Compliance Statement Avis de conformité à la réglementation d Industrie Canada CAN ICES 3 A NMB 3 A CE Australia and New Zealand Statement This is a Class A product In domestic environmen...

Page 8: ...とがあります この場合には使用者が適切な対策を講ずるよう要求されること があります VCCI A 高調波適合品 この装置は 高調波電流規格 JIS C 61000 3 2 適合品です JIS C 61000 3 2 適合品とは 日本工業規格 電磁両立性 第 3 2 部 限度値 高調波電流発生限度値 1 相 当たりの入力電流が 20A 以下の機器 に基づき 商用電力系統の高調波環境目標レベルに適合して設計 製 造した製品です 回線への接続について 本体を公衆回線や専用線に接続する場合は 本体に直接接続せず 技術基準に適合し認定されたボードまたは モデム等の通信端末機器を介して使用してください 電源の瞬時電圧低下対策について この装置は 落雷等による電源の瞬時電圧低下に対し不都合が生じることがあります 電源の瞬時電圧低下対 策としては 交流無停電電源装置 UPS 等を使用されることをお勧めしま...

Page 9: ...lybrominated diphenyl ethers PBDEs not over 0 1wt or 1000wt ppm Ukrainian Декларація про Відповідність Вимогам Технічного Регламенту Обмеження Використання деяких Небезпечних Речовин в електричному та електронному обладнанні затвердженого Постановою 1057 Кабінету Міністрів України Виріб відповідає вимогам Технічного Регламенту Обмеження Використання деяких Небезпечних Речовин в електричному та еле...

Page 10: ...ства или в концентрации до 1000 миллионных частей 5 полибромбифенолы PBB не превышает 0 1 веса вещества или в концентрации до 1000 миллионных частей 6 полибромдифеноловые эфиры PBDE не превышает 0 1 веса вещества или в концентрации до 1000 миллионных частей Disposing of your used product In the European Union EU wide legislation as implemented in each Member State requires that used electrical and...

Page 11: ...over errors or omissions please contact your retailer 5 Regardless of these 4 items NEC Corporation does not take responsibility for effects resulting from operations 6 The sample values used in this document are not the actual values Keep this document nearby so that you may refer to it as necessary Latest editions This document was created based on the information available at the time of its cr...

Page 12: ... OS This chapter describes how to install OS Read through this chapter to set up the system correctly 1 Setup Procedure Describes how to set up VMware 2 Procedures after Completion of Installation Describes how to confirm kernel version and ft control software version and precautions when changing configuration after setup 1 1 ...

Page 13: ...ions 1 1 Requirements for Setup 1 2 Preparations for Setup Use Internal Disk or Use External Storage 1 3 Enabling internal disk 1 4 Enabling FC card 1 5 Disabling OS Boot Monitoring Function 1 7 Installing VMware ESXi 1 8 Installing ftSys Management Appliance 1 9 Installing ft control software 1 11 Setup after installing ft control software Use External Storage Use Internal Disk 1 6 Setting HBA co...

Page 14: ...e contents of this web site is subject to change or delete without notice ESXi 5 5 Update 1 ISO image Includes VMware Tools VMware VMvisor Installer 5 5 0 update01 1623387 x86_64 iso Important ft control software 5 1 1 is applicable to VMware ESXi 5 5 Update1 only Do not install any other version of ESXi VMware vSphere Client This component is required to configure the VMware ESXi installed on ft ...

Page 15: ...RE SETUP CANNOT BE PERFORMED PROPERLY 1 2 1 Prepare NEC Express5800 ft series The components shown below are required for setup AC inlet connector A REAR AC inlet connector B CPU IO module 0 System POWER LED POWER switch CPU IO module 1 DISK ACCESS LED DUMP NMI switch FRONT PRIMARY LED To install ESXi on internal disk only one hard disk drive should be installed in this slot Module POWER LED ...

Page 16: ...not a new one physically format it Refer to Chapter 3 3 SAS Configuration Utility in Maintenance Guide for physical formatting When installing or reinstalling ESXi to the external storage Disconnect all power cords from outlet Remove all the internal hard disk drives If the FC card is not mounted insert the FC cards into the same slot of each CPU IO module Connect each FC card and external storage...

Page 17: ...ware 5 5 17 Chapter 1 Installing OS 1 2 2 Prepare external storage device Note the following when installing ESXi on the external storage device Disk size required for installation Secure at least 25 GB area in boot LUN to install the ESXi host and the ft control system ...

Page 18: ...ke sure that it is powered on 2 Detach the front bezel 3 Press the POWER switch that is located on the front side of the server Lift the acrylic cover and press the POWER switch Important Do not turn off the power before the NEC logo appears After a while the NEC logo will appear on the screen Tips While the NEC logo is displayed on the screen the server performs a power on self test POST to check...

Page 19: ...SETUP will start after POST and the Main menu appears You can also start SETUP by pressing F2 while expanding option ROM Example Tips For System Time use Coordinated Universal Time UTC The specified UTC time is applied to the ESXi host to be installed later In ftSys Management Appliance or other guest OS set the time zone for each system 5 When you move the cursor onto Advanced the Advanced menu a...

Page 20: ...ROM Scan will be changed to Enabled 8 Select an item other than SAS Option ROM Scan and press Enter Select Disabled from the parameters displayed and press Enter Repeat these steps for all items other than SAS Option ROM Scan 9 Make sure that SAS Option ROM Scan shows Enabled and all other items show Disabled Example This is the end of steps for enabling internal disk Now the internal disks are en...

Page 21: ...nt bezel 3 Press the POWER switch that is located on the front side of the server Lift the acrylic cover and press the POWER switch Important Do not turn off the power before the NEC logo appears After a while the NEC logo will appear on the screen Tips While the NEC logo is displayed on the screen the server performs a power on self test POST to check itself For details refer to Chapter 3 1 1 POS...

Page 22: ...SETUP will start after POST and the Main menu appears You can also start SETUP by pressing F2 while expanding option ROM Example Tips For System Time use Coordinated Universal Time UTC The specified UTC time is applied to the ESXi host to be installed later In ftSys Management Appliance or other guest OS set the time zone for each system 5 When you move the cursor onto Advanced the Advanced menu a...

Page 23: ...ple 7 Among the parameters choose Enabled and press Enter The current display of the configuration for PCI Slotx Option ROM will be changed to Enabled 8 Select an item other than PCI Slot x Option ROM for the PCI slot in which FC card is installed and press Enter Select Disabled from the parameters displayed and press Enter Repeat these steps for all items other than PCI Slot x Option ROM for the ...

Page 24: ...ng OS 9 Make sure that PCI Slot x Option ROM for the PCI slot in which FC card is installed shows Enabled and all other items show Disabled Example This is the end of steps for enabling FC card Then disable OS boot monitoring feature Go to 1 5 Disabling OS Boot Monitoring Function and continue setup ...

Page 25: ... system will be forcibly restarted while OS setup screen is shown and the setup will be unsuccessful BIOS may repeat OS setup in an invalid manner If setup fails you must re install the operating system Tips For details of operations for BIOS Setup Utility and parameters for boot monitoring function refer to Chapter 3 1 System BIOS in Maintenance Guide 1 When you move the cursor onto Server the Se...

Page 26: ...ow shown below select Yes to save parameters and exit SETUP Now OS Boot Monitoring function is disabled System reboots when SETUP completes Tips When installing ESXi power off the server for preparation of installation To continue with the setup procedure proceed to 1 6 Setting HBA configuration by using QLogic on the next page if the FC card is enabled and to 1 7 Installing VMware ESXi if the int...

Page 27: ...on by using QLogic BIOS it is required to complete the storage settings such as creating a logical disk 1 Start from the CPU IO module 0 and then perform the following Important Make sure that the PRIMARY LED on CPU IO module 0 is lit 1 1 In the QLogic prompt window which appears during POST press Ctrl Q or Alt Q to launch QLogic Fast UTIL 1 2 Select Configuration Settings and then press Enter ...

Page 28: ... R320d E4 R320d M4 Installation Guide VMware 5 5 28 Chapter 1 Installing OS 1 3 Select Adapter Settings and then press Enter 1 4 Select Host Adapter BIOS and then press Enter to change the setting to Enabled The default is Disabled ...

Page 29: ...dure Express5800 R320d E4 R320d M4 Installation Guide VMware 5 5 29 Chapter 1 Installing OS 1 5 Press ESC once to return to the Configuration Settings screen 1 6 Select Selectable Boot Settings and then press Enter ...

Page 30: ...0d E4 R320d M4 Installation Guide VMware 5 5 30 Chapter 1 Installing OS 1 7 Select Selectable Boot and then press Enter to change the setting to Enabled The default is Disabled 1 8 Select Primary Boot Port Name Lun and then press Enter ...

Page 31: ...re 5 5 31 Chapter 1 Installing OS 1 9 The storage devices that are recognized by the FC card are displayed in the Select Fibre Channel Device window Select the storage device to boot and then press Enter 1 10 In the Select LUN window select LUN to boot and then press Enter ...

Page 32: ... 1 9 and 1 10 respectively are applied to Primary Boot Port Name Lun Note The images shown in steps 1 9 through 1 11 are examples The information displayed varies depending on the product name of external storage and settings such as logical disk settings 1 12 Press ESC twice to display the confirmation window Select Save changes and then press Enter ...

Page 33: ... all the power cords from the server Note Make sure that System POWER LED is unlit before disconnecting the power cord 3 Connect power cords in the following order to start the system from CPU IO module 1 1 Connect a power cord to AC inlet connector B 2 Connect a power cord to AC inlet connector A Important Make sure that the PRIMARY LED on CPU IO module 1 is lit Note If you disconnect a power cor...

Page 34: ...r configuring the settings for the CPU IO module 1 set the CPU IO module 0 as primary Press the POWER switch on front panel to turn off the server Then disconnect all the power cords from the server Note Make sure that System POWER LED is unlit before disconnecting the power cord 6 Connect power cords in the following order to start the system from CPU IO module 0 1 Connect a power cord to AC inle...

Page 35: ...e VMware ESXi 5 5 Update1 Install DVD into the DVD drive of the server 2 If the Boot Menu screen appears after booting the server select ESXi 5 5 0 xxxx standard installer and press Enter The Installer will automatically starts in a few seconds even if Enter is not pressed 3 When an installation confirmation message appears press Enter 4 When the End User License Agreement EULA screen for ESXi app...

Page 36: ...ance see Chapter 1 1 8 Installing ftSys Management Appliance When installing ESXi to the internal disk Tips The installer of ESXi recognizes MPM device as a remote disk Thus the inserted internal disk is placed under Remote category Important Note the following when reinstalling ESXi If any data is contained in the destination disk the installer does not display a message to prompt you to save dat...

Page 37: ...to determine it and then press Enter 7 When the keyboard layout selection screen appears select your desired keyboard layout and press Enter 8 When the root password entry screen appears enter the password and press Enter 9 When the installation confirmation screen appears press F11 to start the installation 10 In the Installation Complete screen press Enter The VMware ESXi Install DVD is ejected ...

Page 38: ...nect both of them Connect LAN cables to Port 1 connectors 1Gigabit on CPU IO modules 0 and 1 At installation the standard switch vSwitch0 is created on this connector R320d E4 Model R320d M4 Model When the installed ESXi boots press F2 and log in to the system as a root user On the System Customization menu configure each item as shown below Connect LAN cable here Connect LAN cable here ...

Page 39: ...a correct hostname and IP address If an inappropriate DNS server is specified installation may fail Note You can configure the DNS server after completion of installation If the host name is changed perform steps described in Chapter 1 2 3 1 If the ESXi Host IP address or root user password has been changed 1 Select Configure Management Network and press Enter 2 Select DNS Configuration and press ...

Page 40: ...C to return to the System Customization menu Press ESC to log out Important Do not change the network configuration that is created at installation of the ESXi host before the setup procedure described in this guide completes If you need to add standard switch perform it after setup process completes Note Set Configuration Management Network and Troubleshooting Options according to your environmen...

Page 41: ...from the vSphere Client Connect to the ESXi host from vSphere Client to configure 1 Connect to the ESXi host ft server from vSphere Client In the Configuration tab select Software Security Profile Firewall to open Properties 2 On the Firewall Properties screen select the syslog checkbox and click OK With this step the ESXi installation has been completed ...

Page 42: ...onnect to the vCenter Server Do not add ESXi host to vCenter Server before the installation of ftSys Management Appliance completes 1 8 1 Checking the Installation Destination Disk Note ftSys Management Appliance must be installed on the disk where the ESXi host exists If several disks are contained in your system perform the steps below in advance 1 Select the ESXi Host in vSphere Client select a...

Page 43: ...ESXi host Example when installed to internal disk Example when installed to external storage Note Make sure the storage has the same name as that you have written down in Chapter 1 1 7 Installing VMware ESXi Tips On the Storage screen displayed in Chapter 1 1 8 2 Installing ftSys Management Appliance you cannot confirm the property of storage You need to confirm it in advance by performing steps d...

Page 44: ...t control software Install DVD into the DVD drive of the machine on which the vSphere Client is installed 2 Start vSphere Client and connect to the ESXi host 3 On the vSphere Client select File Deploy OVF Template 4 Click Browse in the screen to open the appliance folder of the DVD select the ova file and click Next 5 In the OVF Template Details screen click Next ...

Page 45: ...played After clicking Accept for the whole part click Next 7 In the Name and Location screen enter the name of ftSys Management Appliance and click Next Note For naming ftSys Management Appliance it is recommended to create a consistent naming convention in the light of the system operations management The character string ftSysMgt is a prefix automatically added by Installer Ex ftSysMgt ESXi host...

Page 46: ...of the ESXi host and click Next Important ftSys Management Appliance must be installed on the disk where the ESXi host exists Accordingly you need to select a disk you have selected at installation of ESXi 9 On the Disk Format screen the following items are displayed Thick Provision Lazy Zeroed Thick Provision Eager Zeroed Thin Provision Select the Thick Provision Lazy Zeroed and click Next ...

Page 47: ...de VMware 5 5 47 Chapter 1 Installing OS 10 On the Ready to Complete screen select the Power on after deployment checkbox and click Finish 11 When the deployment is completed make sure that ftSys Management Appliance is added to the ESXi host and power is turned on ...

Page 48: ...tion may fail Tips You can configure the DNS server after completion of installation 13 To use a static IP address From the main menu of ftSys Management Appliance select Configure Network Press 6 following the prompt Enter a menu Number 0 to specify the IP address Then press 1 to return to the main menu of ftSys Management Appliance 14 To specify a time zone From the main menu of ftSys Management...

Page 49: ...ains ft control software Install DVD 4 Log in to ftSys Management Appliance as a root user The initial password is ftServer 5 Run the following command on ftSys Management Appliance console opt ft sbin ft install dev cdrom 6 When the IP address entry screen of the ESXi host appears enter the IP address of the ESXi host and press Enter Name or IP Address of the host machine _ 7 Enter the root user ...

Page 50: ...he ft module registration and disk duplication are performed These processes take several tens of minutes Note The time required for completing the duplication varies depending on the disk space Note The system will reboot twice if ft control software is installed in internal hard disk drive 13 After the system reboot confirm that the System FT LED at the front of the server lights Tips When insta...

Page 51: ...1 Setup Procedure Express5800 R320d E4 R320d M4 Installation Guide VMware 5 5 51 Chapter 1 Installing OS ...

Page 52: ... with the ESXi host Performing time synchronization by NTP on the ESXi host makes the time of ftSys Management Appliance is also synchronized Tips The time synchronization with the ESXi host is configured when ft control software is installed The Summary tab of ftSys Management Appliance Options tab in properties of virtual machine that is displayed from Edit Settings and Synchronize guest time wi...

Page 53: ...g Patch Program Visit the VMware s web site shown below and download the patch program VMware ESXi 5 5 Patch Release ESXi550 201404001 2076120 http kb vmware com selfservice microsites search do language en_US cmd displayKC externalId 2076120 The contents of this web site is subject to change or delete without notice ...

Page 54: ...ter 2 1 1 NEC ESMPRO Agent of this document because the log server will be automatically configured and forwarding the logs generated by the ESXi becomes available Note To use any other server than ftSys Management Appliance as the log server you need to prepare a Linux server separately See Chapter 3 1 Steps for Configuring the Separate Log Server of this manual for how to configure the Linux ser...

Page 55: ...eriod from the startup of ESXi host to restart of log server is not transferred to log server If the log server other than ftSys Management Appliance is used and the syslog is to be transferred via TCP using rsyslog transferring of log from ESXi host will not be automatically restarted Run the following command to reload the syslog daemon esxcli s IP address of ESXi server or machine name system s...

Page 56: ...all sh When a separate Linux server is set as the log server mnt cdrom NEC install sh a 6 Select a keyboard layout us for English 101 or jp for Japanese 106 and press Enter Please choose a keyboard layout us 101 jp 106 7 Select a language English or Japanese for NEC ESMPRO report table and enter E or J Please choose a language for ESMPRO alert messages E nglish J apanese Note If using a separate L...

Page 57: ...e System FT LED on the front of the server lights 2 Run the following command to confirm if the system is running normally opt ft sbin ft verify The results list for each of the configuration is output If all items show PASS it indicates that the installation has been completed successfully Output example ftSys Management Appliance hosted by xxx xxx xxx xxx PASS Host is configured with enough memo...

Page 58: ...r a port is duplicated When you change the network configuration or configure the duplication setting by adding a LAN card it is necessary to configure the settings from vSphere Client For detailed procedures refer to the User s Guide and VMware vSphere documents packaged with this guide from the following Website by selecting Release 5 5 http www vmware com support pubs vsphere esxi vcenter serve...

Page 59: ...ing Function Enables OS Boot Monitoring feature Set OS Boot Monitoring feature to Enabled on BIOS SETUP according to Chapter 1 1 5 Disabling OS Boot Monitoring Function Then specify the timeout time for OS Boot Monitoring Timeout parameter appropriately Tips Specify the timeout time in seconds Default setting is 600 seconds 10 minutes ...

Page 60: ...tate the system information 1 14 1 BIOS SETUP 1 Power on the server and run POST 2 Press F2 while the following message is displayed on the screen Press F2 SETUP F4 ROM Utility F12 Network 3 When POST completes write down the new setting values Example Advanced PCI Configuration SAS Option ROM Scan Advanced PCI Configuration PCI Slot x Option ROM Security Server OS Boot Monitoring Server AC LINK S...

Page 61: ...em Information Write down the following system information Product Name FR Number Serial Number 4 Press ESC several times until the following menu appears 1 14 3 BMC Configuration 1 Choose BMC Configuration BMC Configuration Write down the BMC Configurations that have changed Example Network CPU IO module0 Property Network CPU IO module1 Property User Management User Account 2 Press ESC some times...

Page 62: ...stalling guest OS see the vSphere Virtual Machine Administration Guide of VMware vSphere For the network configuration refer to the vSphere Networking Guide packaged with this guide and the ESXi Configuration Guide of VMware vSphere Note Guest OS cannot use the DVD drive on the ESXi host during operation To use the DVD drive select Client Device for properties setting of the guest OS ...

Page 63: ...ild and Update are exactly same as those shown above Note The Build column shows the number given after the patch program was applied ftSys Management Appliance 1 Run the following command on the ftSys Management Appliance 2 6 18 274 e15 indicates version of kernel and 1 SMP Fri Jul 22 04 43 29 EDT 2011 indicates release information of kernel Make sure that the version of kernel is correct This co...

Page 64: ...g the steps below Note Running the following command may fail if the necessary process does not run immediately after the system startup In this case wait for a while several minutes or so and try again 1 Run the following command on the ftSys Management Appliance The version of the ft control software in operation is displayed Make sure that the version is exactly same as that shown above This co...

Page 65: ...ost Name has been Changed If the IP address of log server or host name has been changed perform the following steps Note See Chapter 1 1 11 1 Log Server for the log server 1 Log in to ftSys Management Appliance as a root user 2 Run the build loghost command and specify the log server The new IP address or the host name is recognized as the log server opt ft sbin build loghost update l IP address o...

Page 66: ...Output 162 snmp trap Output 443 tcp https Output 5989 tcp sfcbd https Output 3052 APC 1 When the log server is configured on ftSys Management Appliance Use the report method except the Manager Report SNMP change the setting of the firewall NEC ESMPRO Agent in the table referred to as Agent list of port to use when the report is the following Direction in the table include the bi directional arrows...

Page 67: ... ft verify 5 If successful PASS appears in the output ftSys Management Appliance hosted by xxx xxx xxx xxx PASS Host is configured with enough memory PASS ftSys installed on host PASS Host software version matches appliance 5 1 1 233 PASS ftSys Management Appliance firewall settings PASS ftSys Management Appliance installed on boot volume PASS Multiple paths to storage PASS Network Configuration P...

Page 68: ... This chapter provides brief explanation of bundled software and how to install them 1 Bundled Software for the Server Describes the bundled software to be installed in the server system 2 Bundled Software for Management PC Describes the bundled software to be installed in Management PC that is used to monitor and manage the server system 2 2 ...

Page 69: ...s necessary to configure the settings according to your environment See the User s Guide NEC esmpro sa doc lnx_esm_users_e pdf included in the ft control software Install DVD NEC ESMPRO Agent is stored in the ft control software Install DVD Described below are procedures to configure the ft Management Appliance as the log server If you use any other server as the log server see Chapter 3 1 Steps f...

Page 70: ...t In the case of off change setting of snmpd and start snmpd sbin chkconfig level 35 snmpd on etc init d snmpd start 4 Check the runlevel 3 and 5 of portmap is on sbin chkconfig list portmap In the case of on it is not necessary to change setting of portmap In the case of off change setting of portmap and start portmap sbin chkconfig level 35 portmap on etc init d portmap start portmap 0 off 1 off...

Page 71: ...oftware Install DVD When mnt cdrom directory exists the making of the directory is unnecessary by mkdir command mkdir mnt cdrom mount dev cdrom mnt cdrom 5 Run the following command to change the directory that contains NEC ESMPRO Agent cd mnt cdrom NEC esmpro sa 6 Run the following command to install the NEC ESMPRO Agent rpm ivh Esmpro 7 Run the following command to change setting of ESMstrg sbin...

Page 72: ...t 12 Perform a basic configuration of the Manager Report SNMP 1 Start the ESMamsadm see Chapter 3 Report Features 1 Report Setting Method of starting the Control Panel ESMamsadm of NEC ESMPRO Agent User s Guide 2 Set a trap notification destination IP see Chapter 3 Report Features 2 1 1 Base Setting of Manager SNMP of NEC ESMPRO Agent User s Guide 13 Perform the automatic discovery of servers in N...

Page 73: ...manage the server system 2 1 NEC ESMPRO Manager NEC ESMPRO Manager remotely controls and monitors the server hardware Install NEC ESMPRO Manager on management PC To use these features install the bundled software such as NEC ESMPRO Agent on the server For details about the system requirements of NEC ESMPRO Manager and how to install it refer to NEC ESMPRO Manager Installation Guide xxx doc jp pdf ...

Page 74: ...press5800 R320d E4 R320d M4 Configuring the Separate Log Server This chapter provides how to configure the log server other than ftSys Management Appliance 1 Steps for Configuring the Separate Log Server Describes how to configure the log server other than ftSys Management Appliance 3 3 3 ...

Page 75: ... Log Server or Host Name has been Changed so that the Linux server log server can be detected After configuring the server as described above provide the following settings according to your environment Tips If the separate log server is used some event logs related to internal disk are not reported because these logs are output to syslog of ftSys Management Appliance If you install NEC ESMPRO Age...

Page 76: ... mail none authpriv none cron none local4 none local6 notice var log messages 3 Restart syslog service syslog restart Examples of setting an environment to use rsyslog 1 To set the 514 udp port in waiting state edit etc sysconfig rsyslog Before the change Provides UDP syslog reception ModLoad imudp so UDPServerRun 514 After the change Provides UDP syslog reception ModLoad imudp so UDPServerRun 514...

Page 77: ...alled restart NEC ESMPRO Agent rpm qa grep ftexp report table ftexp report table language ID version rpm e ftexp report table language ID opt nec esmpro_sa bin ESMRestart 1 Log in to the log server as a root user 2 Mount the ft control software Install DVD When mnt cdrom directory exists the making of the directory is unnecessary by mkdir command mkdir mnt cdrom mount dev cdrom mnt cdrom 3 Run the...

Reviews: