background image

AccuSync PV Series External Control Device Setup

SERVICE

Y

Pb

Pr

COMPONENT IN

(L) AUDIO (R)

S-VIDEO IN

RS-232

< Back panel of the set >

1

2

3

8

7

6

4

5

Connect the RS-232 input jack to a control device (such as a 
computer or an A/V control system) in order to control the set’s 
functions externally.

RJ-45 8PIN CONNECTOR

Connect External Equipment

NO.  PIN NAME
1

RXD(RECEIVE DATA)

2

TXD(TRANSMIT DATA)

3
4

GND

5
6

NO CONNCETION

7

NO CONNCETION

8

NO CONNCETION

Communication Parameters

• Baud rate : 9600bps (UART)

• Data length : 8bits

• Parity : None

• Stop bit : 1bit

• Communication code : HEX code

GND

NO CONNCETION

1

2
3
4

...

1

2

3, 4

Connect the serial port of the control device to the RS-232 jack on
the set.

RS-232 connection cables are not supplied with the Monitor.

The Monitor remote control and front panel controls (except main
power) will not be functional if the set is controlled by a PC 
computer or other external device.

1

Summary of Contents for ASPV46-AVT - AccuSync - 46" LCD TV

Page 1: ...1 RXD RECEIVE DATA 2 TXD TRANSMIT DATA 3 4 GND 5 6 NO CONNCETION 7 NO CONNCETION 8 NO CONNCETION Communication Parameters Baud rate 9600bps UART Data length 8bits Parity None Stop bit 1bit Communicat...

Page 2: ...External Control Device Setup Hyper Terminal Setting 1 Run Start Programs Accessories Communications Hyper Terminal 2 Enter a name and chose an icon for the connection 2...

Page 3: ...up Hyper Terminal Setting 3 Enter your Serial RS 232 Port number For example set to COM1 COM2 or etc 4 Set up the port setting as below Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow co...

Page 4: ...External Control Device Setup Hyper Terminal Setting 3 Open File Properties 4 Chose the Setting tab and click the ASCII Setup button as following image 4...

Page 5: ...tton and then button to select the SETUP menu Press the button and then button to select Set ID Press the button and then button to adjust Set ID to choose the desired monitor ID number The adjustment...

Page 6: ...M k l 0 4 13 SSM k m 0 4 14 PIP Mode PIP POP DW1 DW2 k n 0 4 15 PIP input source k o 0 4 16 PIP Position k p 0 3 17 Volume Control k q 0 64 18 Balance k r 0 64 19 AVL k s 0 1 20 SRS k t 0 1 21 TV Spea...

Page 7: ...3 Option 1 TV 3 AV2 5 S Video 7 PC RGB 9 HDMI2 k b Set ID Data Cr OK Acknowledgement b Set ID OK Data x OK Acknowledgement The Monitor transmits ACK acknowledgement based on this format when receiving...

Page 8: ...harpness in the PICTURE menu Transmission Data Min 0 Max 64 Refer to Real data mapping See page 52 k j Set ID Data Cr OK Acknowledgement j Set ID OK Data x 11 CSM Command 2 k To adjust colour temperat...

Page 9: ...remote con trol Transmission k q Set ID Data Cr OK Acknowledgement q Set ID OK Data x 18 Balance Command 2 r To adjust sound balance You can also adjust balance in the SOUND menu Transmission Data Min...

Page 10: ...64 41 Step 65 42 Step 66 43 Step 67 44 Step 68 45 Step 69 46 Step 70 47 Step 71 48 Step 72 49 Step 73 4A Step 74 4B Step 75 4C Step 76 4D Step 77 4E Step 78 4F Step 79 50 Step 80 51 Step 81 52 Step 8...

Reviews: