background image

CX320 Switch Module
V100R001

User Guide

Issue

09

Date

2019-08-02

HUAWEI TECHNOLOGIES CO., LTD.

Summary of Contents for CX320

Page 1: ...CX320 Switch Module V100R001 User Guide Issue 09 Date 2019 08 02 HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...scribed in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the pre...

Page 3: ...tes an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment da...

Page 4: ...06 2018 04 25 Added the descriptions about how to query the MX517 and MX527 cards and how to use the MX517 card ports 05 2018 03 30 This issue is the fifth official release 04 2017 09 14 The issue is the fourth official release 03 2017 09 04 The issue is the third official release 02 2017 07 27 This issue is the second official release and includes the following changes The maximum power consumpti...

Page 5: ...4 3 Setting an IP Address for the Management Network Port 56 4 4 Logging In to the CLI of Each Switching Plane 58 4 5 Checking the Switching Plane 62 4 6 Changing Initial User Passwords 64 4 7 Adding a User 69 4 8 Configuring Switching Service Data 71 4 9 Backing Up the Configuration File 75 5 Restoring the Configuration File 79 6 Common Operations 82 6 1 Logging In to or a Switch Module over MM91...

Page 6: ...o Collect converged switching plane Information 99 6 8 Configuring an FTP Server 99 6 9 Using the CLI to Collect converged switching plane Information 101 A Appendix 106 A 1 Logging In to the CX320 BIOS 106 CX320 Switch Module User Guide Contents Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd v ...

Page 7: ...y personnel certified or authorized by Huawei are allowed to install the hardware l Discontinue any dangerous operations and take protective measures Problems that may cause personal injury or device damage should be immediately reported to the project supervisor l Do not operate the product or handle cables during thunderstorms l Exercise caution when using tools that could cause personal injury ...

Page 8: ... watches and jewelry Figure 1 2 shows conductive objects that must be removed before you touch a device Figure 1 2 Conductive objects to be removed Figure 1 3 shows how to wear an ESD wrist strap 1 Secure the ESD wrist strap around your wrist 2 Fasten the strap buckle and ensure that the ESD wrist strap is touching your skin 3 Insert the ground terminal attached to the ESD wrist strap into the jac...

Page 9: ...grounded before powering it on Transportation Precautions Exercise caution when transporting equipment l The logistics company engaged to transport the equipment must be reliable and comply with international standards for transporting electronics l Ensure that the equipment being transported is always upright Take necessary precautions to prevent collisions corrosion package damage damp condition...

Page 10: ...pean Committee for Standardization CEN 25 55 13 International Organization for Standardization ISO 25 55 13 National Institute for Occupational Safety and Health NIOSH 23 50 72 Health and Safety Executive HSE 25 55 13 General Administration of Quality Supervision Inspection and Quarantine of the People s Republic of China AQSIQ l Men 15 33 01 l Women 10 22 05 CX320 Switch Module User Guide 1 Safet...

Page 11: ...opic describes the logical structure of the CX320 2 7 Internal Networking of a Chassis This topic describes connection relationships between the CX320 and mezzanine cards on compute nodes 2 8 Software and Hardware Compatibility This topic describes the software and hardware supported by the CX320 2 9 Technical Specifications This topic describes the physical environmental power and network switchi...

Page 12: ... passive cables Each 40GE optical port can be divided into four 10GE optical ports l 10GE optical ports on the panel support multi mode optical cables single mode optical cables and passive cables and can be merged into 40GE optical ports l MX517 PIC card with 10GE 8G FC unified ports NOTE l 10GE optical ports support multi mode and single mode optical modules GE or 10GE l 10GE optical ports suppo...

Page 13: ...ng l Static dynamic and blackhole MAC address entries l Filtering based on source MAC addresses l Port based MAC learning limiting Link Layer Discovery Protocol LLDP LLDP Ethernet loop protection Multiple Spanning Tree Protocol MSTP l Spanning Tree Protocol STP l Rapid Spanning Tree Protocol RSTP l MSTP l VLAN based Spanning Tree VBST with the maximum number of protected VLANs of 128 and maximum n...

Page 14: ...snooping l DHCP relay l DHCPv6 relay IP forwarding Unicast routing l IPv4 and IPv6 static routing l Routing Information Protocol Version 1 2 RIP 1 RIP 2 and RIPng l OSPFv2 and OSPFv3 l Intermediate System to Intermediate System IS IS l Border Gateway Protocol Version 4 BGP4 and BGP4 l Routing policies l Policy based routing l Unicast Reverse Path Forwarding URPF check MPLS l LDP l MPLS QoS Uniform...

Page 15: ... between BFD and OSPF l Association between BFD and OSPFv3 l Association between BFD and IS IS l Association between BFD and IS IS IPv6 l Association between BFD and BGP l Association between BFD and BGP4 l Association between BFD and PIM IPv4 l Association between BFD and PIM IPv6 l Association between BFD and IPv4 static routing l Association between BFD and IPv6 static routing l Association bet...

Page 16: ...t queuing l Association between traffic classification and traffic behavior Priority mapping l Mapping from 802 1p priorities to PHBs and colors l Mapping from PHBs and colors to 802 1p priorities l Mapping from DSCP to PHBs and colors l Mapping from PHBs and colors to DSCP l Mapping from EXP priorities to PHBs and colors Queue scheduling l Priority queuing PQ scheduling l Deficit round robin DRR ...

Page 17: ...l configuration l Dynamic VXLAN tunnel configuration through EVPN BGP Virtualization awareness NOTE Only the 10GE switching plane supports this feature l Virtualization awareness l Automatic deployment of policies l Automatic migration of policies l NLB cluster association l Association between one multicast MAC address and multiple outbound ports Server cluster NOTE Only the 40GE switching plane ...

Page 18: ...SFTP Debugging and maintenance l Unified management of logs alarms and commissioning information l Electronic labels l User operation logs l Detailed debugging information for network fault diagnosis l Network testing tools such as Tracert and Ping l Port mirroring and traffic mirroring Version upgrading l Device software loading and online software loading l Online upgrade through the basic input...

Page 19: ... offsets attacks from repeated packet fragments Tear Drop attacks Syndrop attacks NewTear attacks Bonk attacks Nesta attacks Rose attacks Fawx attacks Ping of Death attacks and Jolt attacks Defense against TCP SYN flood attacks UDP flood attacks including Fraggle attacks and UDP diagnosis port attacks and ICMP flood attacks l Logs about attacking MAC addresses l URPF l 802 1x authentication Networ...

Page 20: ...cards can be installed in the same CX320 switch module Appearance Figure 2 1 CX320 Figure 2 2 MX517 flexible PIC card CX320 Switch Module User Guide 2 Product Overview Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 14 ...

Page 21: ...ons The CX320 can be installed in one of the four slots at the rear of the E9000 chassis The four slots are 1E 2X 3X and 4E as shown in Figure 2 4 CX320 Switch Module User Guide 2 Product Overview Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 15 ...

Page 22: ...Figure 2 4 Installation positions and slot numbers Panel CX320 Switch Module User Guide 2 Product Overview Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 16 ...

Page 23: ...8 PIC slot 2 9 PIC slot 1 10 10GE optical port 11 Connection status indicator for the 10GE optical port 12 Data transmission status indicator for the 10GE optical port NOTE The numbers on the left of the panel are port numbers The triangle mark directions indicate the port positions CX320 Switch Module User Guide 2 Product Overview Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 17 ...

Page 24: ...n use the Intelligent Computing Compatibility Checker to obtain information about the optical modules supported l If the MX517 provides four FC ports optical modules for FC applications must be installed to implement FC functions You can use the Intelligent Computing Compatibility Checker to obtain information about the optical modules supported l The MX517 card supports mixed Ethernet and FC appl...

Page 25: ...r where Digits 1 to 9 indicate 2001 to 2009 respectively Letters A to H indicate 2010 to 2017 respectively Letters J to N indicate 2018 to 2022 respectively Letters P to Y indicate 2023 to 2032 respectively NOTE The years from 2010 are represented by upper case letters excluding I O and Z because the three letters are similar to the digits 1 0 and 2 l The second character indicates the month where...

Page 26: ... to 4 mapping to slot numbers 1E 2X 3X and 4E l Subcard number indicates the number of a subcard with ports The value ranges from 1 to 22 For details see Table 2 2 Table 2 3 and Table 2 4 l Port number indicates the serial number of the port on the subcard For details see Table 2 2 Table 2 3 and Table 2 4 For example if the CX320 is in slot 2X the first optical Ethernet port on the upper right of ...

Page 27: ...ting to the BMC l fabriccom serial port connecting to the converged switching plane The baud rate is 115200 bit s when the serial port is connected to the BMC or converged switching plane 10GE optical port SFP 8 17 1 to 8 The panel provides eight 10GE optical ports to connect to external networks 40GE optical port QSF P 2 20 1 to 2 The panel provides two 40GE optical ports to connect to external n...

Page 28: ...le PIC card type NOTE l You can run the corresponding command to query the type of the installed PIC card For details see display device card in the CX320 Switch Module V100R001 Command Reference l The MX517 and MX527 cards can be installed in the same CX320 switch module CX320 Switch Module User Guide 2 Product Overview Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 22 ...

Page 29: ... CX320 Switch Module Command Reference NOTE You can run the corresponding command to query the operating type of the optical module installed on the MX517 card For details see display interface transceiver in the CX320 Switch Module V100R001 Command Reference The Transceiver Type information in the command output indicates the operating type of the optical module MX527 PIC card SFP 16G FC port 4 1...

Page 30: ...of the MM910 management modules 2 4 Indicators This topic describes the names meanings colors descriptions and working status of the indicators on the CX320 By observing the indicators you can determine the current operating status of the CX320 Table 2 5 Indicators Label Meaning Color Description STAT Stacking status indicator Green l Off The CX320 is not powered on l Blinking green for only 10 ti...

Page 31: ...then check whether a critical alarm has been generated and Connection status indicator for the 10GE optical port Green l Off The port is not properly connected l Steady green The port is properly connected and Data transmission status indicator for the 10GE optical port Orange l Off No data is being transmitted over the port l Blinking orange Data is being sent or received over the port and 40GE o...

Page 32: ...the port MX527 PIC card Connection status indicator for the FC optical port Green l Off The port is not connected or not properly connected l Steady green The port is properly connected Data transmission status indicator for the FC optical port Orange l Off No data is being transmitted over the port l Blinking orange Data is being sent or received over the port 2 5 Physical Structure This topic de...

Page 33: ...No Name Description 1 CPU Processes protocol packets and performs configuration and management 2 Converged switching module Provides large capacity service packet forwarding as the main function module 3 Heat sink Cools chips Each chip is configured with one heat sink CX320 Switch Module User Guide 2 Product Overview Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 27 ...

Page 34: ...te nodes 6 Midplane power connector Supplies 12 V DC power 2 6 Logical Structure This topic describes the logical structure of the CX320 The BMC module is a management module that provides power control system monitoring and component upgrade functions The CPU system module is the controlling core that processes network protocol packets and enables configurations The converged switching module is ...

Page 35: ...pute nodes On each compute node two mezzanine cards provide ports to connect to the CX320 switch modules as follows l The Mezz1 position connects to the converged switching plane of the CX320 switch modules in slots 2X and 3X l The Mezz2 position connects to the converged switching plane of the CX320 switch modules in slots 1E and 4E CX320 Switch Module User Guide 2 Product Overview Issue 09 2019 ...

Page 36: ... and 3X and connect to Mezz 1 Mapping Between Switch Modules and Mezzanine Card Ports Mapping between CX320 switch modules and ports on the MZ510 The MZ510 provides two 10GE ports ports 1 and 2 which connect to the 10GE switching planes of the CX320 switch modules in slots 2X and 3X respectively as shown in Figure 2 13 CX320 Switch Module User Guide 2 Product Overview Issue 09 2019 08 02 Copyright...

Page 37: ... the converged switching plane of the CX320 in slot 3X as shown in Figure 2 14 Figure 2 14 Mapping between CX320 switch modules and ports on the MZ512 2 8 Software and Hardware Compatibility This topic describes the software and hardware supported by the CX320 For details about the software and hardware supported by the CX320 use the Intelligent Computing Compatibility Checker CX320 Switch Module ...

Page 38: ...y 5 to 95 l Long term storage humidity 30 to 69 l Humidity change rate 20 h Altitude At an altitude of 900 m 2952 72 ft the highest operating temperature is 40 C 104 F When the device is used at an altitude of 900 m to 5000 m the highest operating temperature decreases by 1 C 1 8 F for every increase of 300 m 984 24 ft Corrosive air pollutant l Corrosion rate of the copper test piece 300 Å month i...

Page 39: ...r of MAC addresses 288000 Number of VLANs 4063 NOTE The switch module has 31 reserved VLANs which are VLANs 4064 to 4094 by default This reserved consecutive VLAN range can be configured Number of Address Resolution Protocols ARPs for the device 128000 Jumbo frame length in byte 9216 L3VPN VRF 1024 Multiprotocol Label Switching L2VPN is not supported IP unicast Number of host table entries 128000 ...

Page 40: ...undancy Protocol VRRP 64 NOV3 Number of VXLAN tunnels 15000 Number of broadcast domains 4000 Enhanced Ethernet feature TRILL l Number of network nodes 512 l Number of CE VLANs 4000 l Load sharing specifications 16 links CX320 Switch Module User Guide 2 Product Overview Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 34 ...

Page 41: ...X320 3 2 Removing the CX320 3 1 Installing the CX320 Prerequisites Tools The following tools are available l Protective gloves l Electrostatic discharge ESD gloves l Phillips screwdriver PH3 is 8 mm or 0 31 in CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 35 ...

Page 42: ...p 1 Installed the chassis Step 2 Determine the position for installing the CX320 in the chassis Figure 3 2 shows the slot numbers CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 36 ...

Page 43: ...filler panel 1 Use a Phillips screwdriver to loosen the two M3 captive screws on the switch module filler panel See 1 in Figure 3 3 CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 37 ...

Page 44: ...e 3 3 3 Store the switch module filler panel for future use Step 4 Install the CX320 1 Raise the two ejector levers on the CX320 completely and push the CX320 horizontally into the chassis as far as it will go See 1 and step 2 in Figure 3 4 Figure 3 4 Installing the CX320 CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 38 ...

Page 45: ...tely and pull the filler panel out of the PIC slot horizontally See 1 and 2 in Figure 3 5 Figure 3 5 Removing a PIC card filler panel 2 Lower the handle on the PIC card filler panel See 3 and 4 in Figure 3 5 Step 6 Optional Install a PIC card 1 Raise the handle on the PIC card and push the PIC card into the PIC slot horizontally as far as it will go See 1 2 and 3 in Figure 3 6 CX320 Switch Module ...

Page 46: ... properly See 4 in Figure 3 6 Step 7 Determine the connection relationships between signal cables and ports on the CX320 Figure 3 7 shows the port types and numbers of the CX320 CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 40 ...

Page 47: ...al cable Figure 3 8 Connecting a serial cable Step 9 Connect a 10GE optical module and optical fiber 1 Determine the optical module type and the optical port to be connected depending on site requirements CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 41 ...

Page 48: ...the optical fiber into the optical module See 2 in Figure 3 10 Step 10 Connect a 40GE optical module and optical fiber 1 Determine the optical module type and the optical port to be connected depending on site requirements 2 Remove dust proof caps from the optical module and optical fiber as shown in Figure 3 11 Figure 3 11 Removing dust proof caps CX320 Switch Module User Guide 3 Installing and R...

Page 49: ...e See section 4 Configuring the CX320 End 3 2 Removing the CX320 To replace a switch module see section Replacing a Switch Module in the E9000 Server V100R001 User Guide Impact on the System After the switch module is removed all services running on the switch module stop Prerequisites Tools The following tools are available l Protective gloves l Electrostatic discharge ESD gloves l Phillips screw...

Page 50: ...oval process Procedure Step 1 Determine the CX320 to be removed Figure 3 14 shows the slot numbers CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 44 ...

Page 51: ...nection relationships between signal cables and ports on the CX320 Figure 3 15 shows the port types and numbers of the CX320 CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 45 ...

Page 52: ...moving a serial cable Step 4 Remove a 10GE optical fiber and optical module 1 Remove the optical fiber from the optical module See 1 and 2 in Figure 3 17 2 Install the dust proof cap for the optical module See 3 in Figure 3 17 CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 46 ...

Page 53: ... Determine the optical module type and removal position based on site requirements 2 Remove the optical module horizontally from the optical port See 1 in Figure 3 19 Figure 3 19 Removing an optical module and optical fiber 3 Remove the optical fiber from the optical module See 2 and 3 in Figure 3 19 4 Install dust proof caps for the optical module as shown in Figure 3 20 CX320 Switch Module User ...

Page 54: ...ly out of the chassis See 2 and 3 in Figure 3 21 3 Lower the ejector levers on the CX320 See 4 in Figure 3 21 An ESD bag holds only one switch module 4 Place the removed switch module into an ESD bag Step 7 Optional Remove a PIC card 1 Raise the PIC card handle completely and pull the PIC card horizontally out of the PIC slot See 1 and 2 in Figure 3 22 CX320 Switch Module User Guide 3 Installing a...

Page 55: ...t install a new PIC card immediately install a PIC card filler panel Step 8 Install a PIC card filler panel 1 Raise the handle on the PIC card filler panel completely and push the PIC card filler panel horizontally into the PIC slot See 1 2 and 3 in Figure 3 23 CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 49 ...

Page 56: ...ly See 4 in Figure 3 23 Step 9 Install a switch module filler panel 1 Raise the two handles on the switch module filler panel and push the filler panel horizontally into the chassis as far as it will go See 1 in Figure 3 24 CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 50 ...

Page 57: ...module filler panel See 2 in Figure 3 24 3 Use a Phillips screwdriver to tighten the two M3 captive screws on the switch module filler panel See 3 in Figure 3 24 End CX320 Switch Module User Guide 3 Installing and Removing the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 51 ...

Page 58: ...witching Plane 4 5 Checking the Switching Plane 4 6 Changing Initial User Passwords 4 7 Adding a User 4 8 Configuring Switching Service Data Configure the CX320 feature data after the converged switching plane meets the basic configuration conditions 4 9 Backing Up the Configuration File This topic describes how to back up the configuration file If configuration errors occur or the CX320 is faulty...

Page 59: ...anagement network port of the converged switching plane You can log in to the CLI of the switching plane from a PC by using the IP address of the management network port Log in to the CLI of each switching plane You can log in to the converged switching plane CLI over Secure Shell SSH Serial Over LAN SOL or a serial port CX320 Switch Module User Guide 4 Configuring the CX320 Issue 09 2019 08 02 Co...

Page 60: ...g service data supported by the converged switching plane of the CX320 Back up configuration files Back up the configuration file of the converged switching plane for the CX320 If configuration errors occur or the CX320 is faulty you can use the backup configuration file to restore configuration data Related Documents The following lists the documents related to the converged switching plane of th...

Page 61: ...d U S English keyboard or UK English keyboard l The default BIOS password is Huawei12 for the U S English or French keyboard and is Huawei12 for the UK English keyboard Administrative user Enabled Remote or local login NOTE Remote login is supporte d if the software version of the switchin g plane is 6 30 or later root A user that logs in to the converged switching plane The user has no user name ...

Page 62: ... The IP address of the converged switching plane management network port can be set on the MM910 WebUI For details see the procedure section in this topic l On the converged switching plane CLI run the ip address command to set the IP address of the converged switching plane management network port For details see the CX320 Switch Module Command Reference l On the MM910 CLI run the swipcontrol com...

Page 63: ...ecific slots Step 6 Click Deliver The IP addresses of converged switching plane management network ports are successfully set Step 7 Optional Configure the switching plane gateway 1 Use an SSH connection tool to log in to the MM910 CLI by using the floating IP address of the MM910s This topic describes how to use PuTTY to log in over SSH For details see Logging In to a Server Over a Network Port b...

Page 64: ... through the MM910 SOL screen l Over a serial port Connect a serial cable to the COM serial port of the CX320 and log in to the CLI without using an IP address Prerequisites Data Table 4 5 Default Data Name Default Data Login Method converged switching plane l User name root l Password Huawei12 SSH l No user name l Password Huawei12 l Serial port l SOL Tools If you want to log in to a server CLI o...

Page 65: ...rt is provided by the switch module by default For the MM910 U54 2 26 or later the management port is provided by the MM910 by default For details about how to query the MM910 version see MM910 Management Module V100R001 User Guide You can run the outportmode command to change the mode in which the MM910 management port is provided If the switch module in slot 2X or 3X is used to provide the manag...

Page 66: ...he PC to an idle STACK port on an active MM910 in a chassis cascaded with the E9000 chassis Figure 4 4 shows the connection If the MGMT port on the active MM910 is already connected with a network cable do not remove the network cable from the MGMT port Otherwise an active standby switchover of the MM910s will be triggered which may cause network interruption CX320 Switch Module User Guide 4 Confi...

Page 67: ...example for login over SSH For details see 6 2 Logging In to the MM910 CLI Over a Network Port by Using PuTTY End l Log in to the CLI of a switching plane over SOL Step 1 Connect the Ethernet port on the PC to the MGMT port on the active or standby MM910 For details see Step 1 in Log in to the CLI of a switching plane over SSH CX320 Switch Module User Guide 4 Configuring the CX320 Issue 09 2019 08...

Page 68: ... 2 Logging In to the MM910 CLI Over a Network Port by Using PuTTY Step 3 Log in to the CLI of a switching plane over MM910 SOL For details see 6 1 Logging In to or a Switch Module over MM910 SOL End l Log in to the CLI of a switching plane over a serial port Step 1 Use a DB9 RJ45 cable to connect the RS232 serial port of the PC to the SYS serial port on the CX320 panel Step 2 Use a serial port com...

Page 69: ...Version 5 70 Software Version indicates the current software version Step 3 Check whether the software version is consistent with the desired one l If yes go to Step 4 l If no contact Huawei technical support Step 4 Query the alarms of the converged switching plane HUAWEI display alarm active The command output is as follows 1 Critical 2 Major 3 Minor 4 Warning Sequence AlarmId Severity Date Time ...

Page 70: ...m the flash memory to the random access memory RAM and starts the operating system OS Prerequisites Conditions l You have logged in to the converged switching plane command line interface CLI l You have logged in to the BMC CLI Data Table 4 6 lists the default data required for the login Table 4 6 Default data Name Default Data Description converged switching plane l User name root l Password Huaw...

Page 71: ...ep 4 Enter a new password The password is case sensitive and must meet the following requirements l Contain at least two types of the following characters Uppercase letters A to Z Lowercase letters a to z Digits 0 to 9 At least one of the following special character _ l Cannot be the same as the user name or the user name in reverse order The following information is displayed Confirm Password NOT...

Page 72: ...r changing a password HUAWEI local user change password The command output is as follows Please enter old password Step 2 Enter the old password The following information is displayed Please enter new password Step 3 Enter a new password The password is case sensitive and must meet the following requirements l Contain at least two types of the following characters Uppercase letters A to Z Lowercas...

Page 73: ...rations such as changing the password and system upgrade through disk formatting cannot be performed on the BIOS These operations are supported on the BIOS from switching plane version 6 56 Step 1 Run the following command on the CLI of the converged switching plane to restart the GE switching plane HUAWEI reboot The command output is as follows Warning Current configuration will be saved to the n...

Page 74: ...gain If the following information is displayed the initial user password is successfully changed The password is changed successfully End l Change the initial password of the BMC Step 1 On the CLI of the BMC run the following commands to go to the page for changing the root user password BMC ipmcset d password v root The command output is as follows Input your password Step 2 Enter the initial pas...

Page 75: ...device access commands 1 Monitoring level System maintenance commands such as display NOTE Not all display commands are on the monitoring level For details about the command levels see the CX320 Switch Module V100R001 Command Reference 2 Configuration level Service configuration commands including router commands and the commands at different network layers The commands are used to provide direct ...

Page 76: ... user name to user123 and the password to Huawei12 in cipher text HUAWEI aaa local user user123 password irreversible cipher Huawei12 Info A new user is added NOTE The user name must contain at least six characters Step 5 Set the level of the user user123 to 2 HUAWEI aaa local user user123 level 2 Step 6 Set the user access type local user User name service type terminal telnet ftp ssh all For exa...

Page 77: ...ing plane meets the basic configuration conditions Feature configuration for the converged switching plane is as follows For details see CX320 Switch Module V100R001C10 Configuration Guide Table 4 9 List of configurable features Configuration Type Configuration Item Basic Configuration l ZTP Configuration l Logging In to the System for the First Time l Configuring a User Interface l Configuring Us...

Page 78: ...figuration l VLAN Configuration l QinQ Configuration l VLAN Mapping Configuration l GVRP Configuration l STP RSTP Configuration l MSTP Configuration l VBST Configuration l ERPS G 8032 Configuration l Loopback Detection Configuration l Layer 2 Protocol Transparent Transmission Configuration IP Service l IP Address Configuration l ARP Configuration l DHCP Configuration l DNS Configuration l UDP Help...

Page 79: ...ation l IPv4 Multicast Route Management Configuration l IPv6 Multicast Route Management Configuration l IGMP Snooping Configuration l Static Multicast MAC Address Configuration l Multicast VLAN Replication Configuration l Multicast Network Management MPLS l MPLS LDP Configuration l MPLS QoS Configuration VPN l GRE Configuration Guide l MCE Configuration l IPv6 MCE Configuration DCN and Server Mana...

Page 80: ...ration l DHCP Snooping Configuration l IPSG Configuration l URPF Configuration l SSL Configuration l Keychain Configuration l Separating the Management Port from the Service Plane l Setting the System Root Key QoS l MQC Configuration l Priority Mapping Configuration l Traffic Policing Traffic Shaping and Interface based Rate Limiting l Congestion Avoidance and Congestion Management Configuration l...

Page 81: ...dure Step 1 Log in to the converged switching plane command line interface CLI Step 2 Log in to the MM910 CLI Step 3 Configure the converged switching plane Step 4 Save the converged switching plane configuration file 1 Run the following command on the CLI of the converged switching plane to view the configuration file required for the next startup of the converged switching plane HUAWEI display s...

Page 82: ...the device Continue Y N Y Now saving the current configuration to the slot 1 Info Save the configuration successfully begin synchronize configuration to SMM slot 1 upload configuration to SMM successfully HUAWEI 3 Check that the configuration file is synchronized to the MM910 successfully HUAWEI reboot If the following information is displayed the configuration file is successfully synchronized sl...

Page 83: ...e Built Mar 14 2013 22 31 44 The value of the parameter Software Version is the software version of the MM910 8 Select an operation based on the MM910 software version If the software version is earlier than U54 3 00 go to Step 4 9 to Step 4 11 If the software version is U54 3 00 or later perform Step 4 10 to Step 4 11 9 Use a cross platform file transfer tool and enter the floating IP address of ...

Page 84: ...splayed In the navigation tree on the left choose Transfer and click Binary and OK The configuration file is downloaded to the PC and decompressed The converged switching plane configuration file is 13_1_1 cfg End CX320 Switch Module User Guide 4 Configuring the CX320 Issue 09 2019 08 02 Copyright Huawei Technologies Co Ltd 78 ...

Page 85: ... command line interface CLI Step 2 Log in to the MM910 CLI Step 3 Restore the converged switching plane configuration file 1 Connect the Ethernet port on a PC to the MGMT network ports on the panels of the active and standby MM910 over a local area network LAN If the MGMT port on the active MM910 is already connected with a network cable do not remove the network cable from the MGMT port Otherwise...

Page 86: ... for the existing configuration file and back it up in the MM910 before the uploading Otherwise the existing configuration file in the MM910 will be replaced by the uploaded configuration file For details about the configuration file backup see 4 9 Backing Up the Configuration File l Configuration file name 13_1_1 cfg l The upload path of the configuration file is tmp exchang swiN N ranges from 1 ...

Page 87: ... condition if offline configuration success the blade will reboot Do you want to continue Y N y Success The MM910 restarts automatically after the configuration file is successfully loaded to the converged switching plane and the configuration file is automatically restored after the restart End CX320 Switch Module User Guide 5 Restoring the Configuration File Issue 09 2019 08 02 Copyright Huawei ...

Page 88: ...es on the local computer using WinSCP 6 7 Using the MM910 WebUI to Collect converged switching plane Information This topic describes how to use the MM910 WebUI MM910 software version 6 00 or later to collect logs of the converged switching plane switching plane software version 5 30 or later 6 8 Configuring an FTP Server Configure an FTP server to transfer files from a PC to a switching plane 6 9...

Page 89: ...16A 17 32 Swi1 Swi4 33 36 and COM n press Ctrl R to return Blade1 Blade16 1 16 Blade1A Blade16A 17 32 Swi1 Swi4 33 36 Please input your choice In the information displayed l The numbers 1 to 32 indicate the compute nodes in slots 1 to 32 respectively l The numbers 33 to 36 indicate the switch modules in slots 1E 2X 3X and 4E respectively Step 4 Enter the slot number of the switch module and press ...

Page 90: ...ou can perform operations such as configuring the serial port and querying parameters of the serial port l If another user has logged in to the serial port a message will be displayed asking you whether to forcibly log out the user Press Y to forcibly log out the user Press N to not forcibly log out the user The system stays at the current screen CX320 Switch Module User Guide 6 Common Operations ...

Page 91: ...g in to the MM910 Software PuTTY exe third party software used for remote access on various platforms Procedure Step 1 Connect the local PC and the MGMT port on the MM910 through a network cable Step 2 Set an IP address and a subnet mask or add route information for the PC to enable communication between the PC and the MM910 To check the connectivity between the PC and the device run the Ping MM91...

Page 92: ...SH for Connection type as shown in Figure 6 1 Figure 6 1 PuTTY Configuration Step 8 Optional Choose Terminal Keyboard and select Control H under The Backspace key as shown in Figure 6 2 This setting can solve the problem that the characters on the CLI cannot be deleted by using the Backspace key CX320 Switch Module User Guide 6 Common Operations Issue 09 2019 08 02 Copyright Huawei Technologies Co...

Page 93: ...you must set up a new PuTTY session Step 10 Enter the user name and password If the login is successful the server host name is displayed on the left of the prompt End 6 3 Logging In to a Device Over a Serial Port by Using PuTTY Scenarios Log in to a compute node switch module or management module in an E9000 chassis over a serial port by using PuTTY when CX320 Switch Module User Guide 6 Common Op...

Page 94: ... plane or BMC chip l If the switch module panel has the BMC serial port and SYS serial port the BMC serial port is connected to the BMC chip and the SYS serial port can be connected to the Ethernet switching plane or FC switching plane l If the switch module panel has only the COM serial port the COM serial port can be connected to the Ethernet switching plane FC switching plane or BMC chip l If t...

Page 95: ...ata bits 8 l Stop bits 1 l Parity None l Flow control None NOTE n indicates the serial port number Step 4 Choose Session from the navigation tree Step 5 Select Serial for Connection type as shown in Figure 6 3 Figure 6 3 PuTTY Configuration Step 6 Click Open The following information is displayed CX320 Switch Module User Guide 6 Common Operations Issue 09 2019 08 02 Copyright Huawei Technologies C...

Page 96: ...d on with the chassis This topic does not provide the operation details l If the chassis is powered off the converged switching plane of the CX320 is powered off with the chassis l If the chassis is powered on but the CX320 is not installed install the CX320 and all switching planes of the CX320 are automatically powered on after installation This topic does not provide the operation details l If ...

Page 97: ...ply Management Power Control Figure 6 4 Power Control page 4 Power on or off the converged switching plane of a specific switch module fabric indicates the converged switching plane 5 Refresh the page and check the latest power on and power off status of the switch module End 6 5 Logging In to the MM910 WebUI Scenarios Log in to the HMM WebUI using a browser CX320 Switch Module User Guide 6 Common...

Page 98: ...he WebUI of the standby MM910 you can only view monitoring information about the active MM910 set the DHCP and static IP addresses and set and query the thresholds and hysteresis of the sensors of the standby MM910 To perform other operations log in to the WebUI of the active MM910 l For details about the operations on the WebUI see the Online Help Prerequisites Conditions The client a PC used to ...

Page 99: ...ement port of the management module MGMT port on the MM910 panel For the MM910 U54 2 25 or earlier the management port is provided by the switch module by default For the MM910 U54 2 26 or later the management port is provided by the MM910 by default For details about how to query the MM910 version see MM910 Management Module V100R001 User Guide You can run the outportmode command to change the mo...

Page 100: ...o stack the MGMT port in another chassis connect the PC to an idle STACK port on an active MM910 in a chassis cascaded with the E9000 chassis Figure 6 7 shows the connection If the MGMT port on the active MM910 is already connected with a network cable do not remove the network cable from the MGMT port Otherwise an active standby switchover of the MM910s will be triggered which may cause network i...

Page 101: ...layed Step 4 Choose Connections and click LAN Settings The LAN Settings dialog box is displayed Step 5 In the Proxy server group box deselect Use a proxy server for your LAN and click OK The LAN Settings dialog box is closed Step 6 Click OK The Internet Options dialog box is closed Step 7 Open Internet Explorer again enter https MM910 floating IP address for example https 192 168 2 3 in the addres...

Page 102: ...ck Trusted sites and click Sites 4 In the Trusted sites dialog box click Add to add the MM910 IP address to the trusted site list and click Close 5 Refresh the page 6 In the status bar of a browser check whether the MM910 IP address is in the Trusted sites zone Step 9 Click Continue to this website not recommended The HMM Web login page is displayed as shown in Figure 6 8 Figure 6 8 Logging in to ...

Page 103: ...connected l User name and password for logging in to the server to be connected Procedure Step 1 Enable the SFTP service on the destination device Step 2 Open the WinSCP folder and double click WinSCP exe The WinSCP Login dialog box is displayed as shown in Figure 6 10 NOTE If the operating system OS is not an English system click Languages to set the displayed language CX320 Switch Module User Gu...

Page 104: ... Allow SCP fallback Step 4 Click Login The WinSCP file transfer page is displayed NOTE l If a key file was not selected during the first login a warning Continue connecting and add host key to cache is displayed Click Yes The WinSCP file transfer page is displayed l If Windows 7 is used in the left pane of the page open the C Users Administrator Documents directory the device s root directory is o...

Page 105: ...e MM910 WebUI Step 2 Choose System Management Information Collection and set the information collection parameters l Collected from Select MM l Collected content Select One click full collection Step 3 Click Start Collection to start collecting logs Figure 6 11 Information collection Step 4 In the displayed dialog box click Save and save the log file to the local PC Step 5 Decompress the one_touch...

Page 106: ...ers Rights Security Dialog dialog box is displayed Step 6 Click New User In the dialog box displayed enter a new user name for example vxworks and click OK The Change Password dialog box is displayed Step 7 Enter a new password for example vxworks in the New Password and Verify Password text boxes and click OK Step 8 Copy the upgrade file to a directory for example D FTP on the PC NOTE The directo...

Page 107: ...The default user name of a switching plane is root and the default password is Huawei12 NOTE You can query and set IP addresses of all modules on the MM910 WebUI For details about how to log in to the MM910 WebUI see 6 5 Logging In to the MM910 WebUI l For MM910 earlier than U54 2 20 choose System Management Network Management Switch Module IP Address l For MM910 U54 2 20 or later choose Chassis S...

Page 108: ...witching plane by using a serial port or the Serial over LAN SOL function run the following commands on the switching plane CLI to query and set the IP address of the management network port so that the switch module can properly communicate with the FTP server NOTE Skip this step if you log in to the switch module by using a network port HUAWEI system view HUAWEI interface MEth 0 0 0 HUAWEI MEth0...

Page 109: ...9 POST 6 rw 10 568 Feb 21 2014 18 20 01 cfg_from_smm 7 rw 6 575 Mar 22 2014 04 14 27 cfg_local 8 rw 19 435 Mar 22 2014 04 14 24 device sys 9 rw 1 130 184 Apr 08 2014 16 22 11 diagnostic_information zip 10 drwx Apr 08 2014 16 18 55 logfile 11 rw 1 838 Mar 22 2014 04 14 24 vrpcfg zip 1 048 576 KB total 367 972 KB free HUAWEI dir logfile Directory of flash logfile Idx Attr Size Byte Date Time FileNam...

Page 110: ...ta connection for diag info txt 100 226 File received ok FTP 1756870 byte s send in 0 308 second s 5570 431Kbyte s sec ftp mput flash logfile 200 Port command successful 150 Opening data connection for diag log 100 226 File received ok FTP 7971326 byte s send in 0 798 second s 9755 010Kbyte s sec 200 Port command successful 150 Opening data connection for diaglog_3_20140221182310 log zip 100 226 F...

Page 111: ...follow the preceding procedure to collect logs ftp mkdir swi2 ftp cd swi2 ftp mput 2 flash logfile ftp cd ftp quit 221 Windows FTP Server WFTPD by Texas Imperial Software says goodbye HUAWEI NOTE l When you use the mput command in the FTP CLI 2 flash indicates the flash root directory of the switch module with the ID 2 You can obtain the stack ID and role information by using the display stack com...

Page 112: ... operations such as changing the password and system upgrade through disk formatting cannot be performed on the BIOS These operations are supported on the BIOS from switching plane version 6 56 The BIOS initializes hardware such as serial ports or dual in line memory modules DIMMs reads the kernel image from the flash memory to the random access memory RAM and starts the operating system OS In the...

Page 113: ...to SMM System will reboot Continue Y N Enter Y to restart the converged switching plane 2 Press Ctrl B when the system displays Press CTRL B to enter BIOS menu The command output is as follows Password 3 Enter the BIOS login password The BIOS menu screen is displayed Enter your choice 1 9 BIOS Menu Version 2 42 1 Continue to boot 2 Update from serial interface 3 Update from ethernet interface 4 Mo...