Page 1: ...APAA00001 User Manual Issue Draft A Date 2015 06 12 HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...e customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject...

Page 3: ...ion and method for using operating and maintaining APAA00001 Intended Audience This document is intended for Technical support engineers Maintenance engineers Documentation Obtaining The electronic version of this document can be obtained from http support huawei com Change History Changes between document issues are cumulative The latest document issue contains all the changes in earlier issues D...

Page 4: ...9 3 Networking Guideline 10 3 1 Before Network Deployment 10 3 2 Typical Scenarios 10 3 2 1 ALD Control over the AISG Port 10 3 2 2 ALD Control over the OOK Port 11 3 3 Procedure 12 4 System Maintenance 15 4 1 Routine Maintenance 15 4 1 1 Battery 15 4 1 2 PAA Shell 16 4 1 3 Silicone Shell 16 4 2 Alarm Handling 16 4 2 1 Hardware Fault Alarm Handling 16 4 2 2 AISG OOK Overcurrent Alarm Handling 17 4...

Page 5: ...ents Draft A 2015 06 12 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd iv 5 3 FCC Radiation Exposure Statement 21 5 4 IC RSS warning 21 A Appendix 23 A 1 Acronyms and Abbreviations 23 A 2 Alarm Codes 25 ...

Page 6: ... using an app APAA00001 can be used to control all types of Huawei ALDs If the PAA is to be used with the ALDs supplied by peer vendors you are advised to perform joint commissioning to confirm their compatibility with each other 1 2 Product Specifications Table 1 1 provides the product specifications of APAA00001 Table 1 1 Product specifications of APAA00001 Electrical Specifications Operating Po...

Page 7: ...pecifications Operating Temperature 20 C to 55 C Storage temperature 0 C to 45 C Recharge temperature 0 C to 40 C Humidity 5 to 95 Service Life Three years Mechanical Specifications Weight 0 52 kg including the weight of a rechargeable battery Dimensions H x W x D 204 mm x 88 mm x 30 mm Material PC ABS 30 1 3 Appearance Description 1 3 1 Appearance Figure 1 1 shows the appearance and dimensions of...

Page 8: ...to PAA Draft A 2015 06 12 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 3 Figure 1 1 Appearance and dimensions ofAPAA00001 Figure 1 2 APAA00001 appearance 1 AISG connection port 2 Strap hole 3 OOK connection port ...

Page 9: ...r off by holding down this button 8 Mini USB port Reserved for further development and is not used temporarily 9 12 V DC adapter port Connects to the AC DC adapter When an AC DC adapter is connected the PAA automatically uses the input power supply as the operating power supply to charge the integrated battery Table 1 3 Indicators No Indicator and Silkscreen Description 4 Power indicator PWR Indic...

Page 10: ...to 2 cable 1 PCS 4 N M DIN M adapter 1 PCS 5 N M DIN F adapter 1 PCS 6 RF cable 1 PCS 7 Strap 1 PCS 8 User manual 1 PCS 12 V DC Adapter The adapter parameters are as follows Input 100 V AC to 240 V AC 0 8 A 50 Hz to 60 Hz Output 12 V DC 2 0 AAC DC Figure 1 3 shows the 12 V DC adapter Figure 1 3 12 V DC adapter AISG 1 to 2 Cable The cable specifications are as follows Connectors Each AISG 1 to 2 ca...

Page 11: ...uawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 6 Cable complies with the UL2464 standard Figure 1 4 AISG 1 to 2 cable N M DIN M Adapter Figure 1 5 N M DIN M adapter N M DIN F Adapter Figure 1 6 N M DIN F adapter RF Cable Figure 1 7 RF cable ...

Page 12: ...6 12 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 7 AC Power Cable China standard Power is as shown in figure 1 8 According to the different delivery area the cable will be different Figure 1 8 AC power cable Strap Figure 1 9 Strap ...

Page 13: ... the website Currently PAA is available only on Android smartphones PAA has the following requirements for smartphones Android 4 0 or later 1 5 GHz CPU or higher 1 GB flash memory or higher 2 1 App Download by Scanning the QR Code Procedure Step 1 Scan the QR code on the back of the PAA using the QR code scanning function of your smartphone and then download the PAA app after the scanning is succe...

Page 14: ...tween the smartphone and the PAA through bluetooth can be checked based on the connection state between them After the connection is successful the app notifies the user that the PAA has been connected and the main PAA GUI is displayed In this situation the communication indicator on the PAA blinks If the connection fails a notification indicating the failure is displayed at the lower part of the ...

Page 15: ...er The mode in which the PAA controls an ALD depends on the ALD capability If the ALD supports only the RS485 control mode the PAA controls the ALD over the AISG port For details see section 3 2 1 ALD Control over the AISG Port If the ALD supports only the OOK control mode the PAA controls the ALD over the OOK port For details see section 3 2 2 ALD Control over the OOK Port If the ALD supports bot...

Page 16: ... is used The total length of the AISG cable cannot exceed 50 m Connectors and cables can be used for transfer during cable connection The external power supply switch of the PAA must be turned on when the ALD is connected Figure 3 4 shows the external power supply switch of the PAA 3 2 2 ALD Control over the OOK Port The OOK port on the PAA is connected to the RF port on the ALD as shown in Figure...

Page 17: ... supply switch of the PAA 3 3 Procedure Step 1 Select the networking drawing for cable connection based on the ALD capability Step 2 Power on the PAA When the power indicator is steady on the PAA is powered on properly If the PAA cannot be powered on recharge the PAA by using the AC DC adapter of the PAA When the PAA is being recharged the power indicator blinks Step 3 Open the PAA app on the smar...

Page 18: ...tch on the app to turn on the external power supply switch of the PAA as shown in Figure 3 4 If the power switch on the app turns white the external power supply switch of the PAA has been turned on If the power switch on the app turns gray the external power supply switch of the PAA has been turned off Figure 3 4 Turning on the external power supply switch of the PAA In actual application the PAA...

Page 19: ...APAA00001 User Manual 3 Networking Guideline Draft A 2015 06 12 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 14 Obtain the online help from the menu ...

Page 20: ...mperature sources such as fire or heaters Otherwise the battery may be overheated disconnected or even fail thereby compromising the battery life The PAA cannot be used in places with strong electrostatic and magnetic fields Otherwise the battery safety protection unit may be damaged causing safety issues If the battery becomes smelly overheated discolored or deformed or any other exception occurs...

Page 21: ... The silicone shell cannot be in contact with keen edge objects The silicone shell must not be frequently removed or violently stretched Otherwise the shell may be deformed It is recommended that the silicone shell be cleaned using wet cloth or a toothbrush with toothpaste or alcohol and then washed using clean water Do not soak the silicone shell into water for a long time violently brush the she...

Page 22: ...d write function of the flash memory is faulty The flash memory fails The I2 C bus is faulty The I2 C bus fails Handling Method Restart the PAA If the PAA communicates properly with the smartphone and the alarm is cleared after the restart no further actions are required If the alarm persists the PAA has been damaged In this case replace the PAA with a new one or contact Huawei technical support E...

Page 23: ...sfully turned on the PAA communicates successfully with the ALD and the alarm is cleared After the power supply switch is turned on the PAA forcibly shuts down the external power supply If the alarm still persists go to Step 2 Step 2 Check whether the communication link or each PAA is short circuited If a short circuit occurs rectify the fault and then turn on the external power supply from the PA...

Page 24: ...e possibility of battery self locking increases Minor The battery connector inside the PAA is loosely connected or in poor contact Procedure Contact Huawei technical support so that the PAA can be disassembled or returned to Huawei for maintenance 4 3 Troubleshooting 4 3 1 Battery Fault The battery may fail if any of the following conditions exists The battery is fully recharged within 1 hour Low ...

Page 25: ...2 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 20 If the power button does not work for multiple times when the PAA is used the button or the button spring may be faulty In this case contact Huawei technical support to replace the PAA ...

Page 26: ...limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If thi...

Page 27: ...aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioé lectrique subi mê me si le brouillage est susceptible d en compromettre le fonctionnement IC Radiation Exposure Statement This equipment complies with IC RF radiation exposure limits set forth for an uncontrolled environment This transmitter must not b...

Page 28: ...uawei Technologies Co Ltd 23 A Appendix A 1 Acronyms and Abbreviations A ABS acrylonitrile butadiene styrene AC alternating current AISG Antenna Interface Standards Group ALD antenna line device C CPU central processing unit D DC direct current G GB gigabit GHz gigahertz GUI graphical user interface ...

Page 29: ...uawei Technologies Co Ltd 24 I I2C inter integrated circuit IEC International Electrotechnical Commission O OOK on off keying P PAA portable AISG adapter PC personal computer Q QR quick response code R RCU remote control unit RF radio frequency U URL uniform resource locator USB Universal Serial Bus ...

Page 30: ...larm Codes The following alarm codes may be displayed on the PAA Alarm Code Type Displayed Information Remarks 0x11 Alarm code Hardware Error A hardware alarm is reported 0x30 Alarm code AISG OOK Over Current An AISG OOK overcurrent alarm is reported 0x32 Alarm code Battery Not In Position A battery not in position alarm is reported ...