The HP Smart Array P822 Controller is a Full height, 6 Gb/s, PCIe 3.0, Serial Attached SCSI (SAS) RAID controller that provides enterprise
class, second generation storage performance, maximum external scalability, and data protection for select HP ProLiant Gen8 rack
servers and tower servers.

It features two internal and four external SAS ports. Advanced storage functionality, including online RAID level migration with flash
backed write cache (FBWC), global online spare, and pre-failure warning all result in increased server uptime. Data compatibility gives
customers an easy upgrade path to future Smart Array Controllers.

HP Smart Array Advanced Pack 2.0 is included with this controller providing advanced functionality, including features such as RAID 1
ADM (Advanced Data Mirroring), making it easier for customers to protect their data.
 

What's New

HP SmartCache is base feature of this controller that improves application workload performance by caching hot data to SSDs
Up to 4x better Solid State Disk (SSD) read performance with the SSD Smart Path firmware and driver based feature for Smart
Array controllers

QuickSpecs

HP Smart Array P822 Controller

Overview

DA - 14341   North America — Version 11 — September 10, 2013

Page  1

Summary of Contents for 615418-B21

Page 1: ...ased server uptime Data compatibility gives customers an easy upgrade path to future Smart Array Controllers HP Smart Array Advanced Pack 2 0 is included with this controller providing advanced functionality including features such as RAID 1 ADM Advanced Data Mirroring making it easier for customers to protect their data What s New HP SmartCache is base feature of this controller that improves app...

Page 2: ...art Array P822 Controller HP Smart Array P822 2GB FBWC 2 ports Int 4 ports Ext SAS Controller 615418 B21 QuickSpecs HP Smart Array P822 Controller Overview DA 14341 North America Version 11 September 10 2013 Page 2 ...

Page 3: ...pport Center or refer to your HP Server documentation Key Features Seamless upgrades to and from other HP Smart Array controllers Storage interface SAS SATA Two Mini SAS 4i connectors for attachment to internal drive backplanes Four Mini SAS 4x connectors for attachment to JBODs and external tape drives 6 Gb s SAS technology delivers up to 600 MB s per physical link 6 Gb s SATA technology delivers...

Page 4: ...er is lost the data is copied into flash memory of the cache module drawing power from attached capacitors When power is restored if the flash memory chips contain write data the data is copied back into the DRAM so it can be flushed to the drives Advantages over battery backed cache architectures include No 72 hour deadline for retrieving the data before the batteries fully discharge Capacitors c...

Page 5: ...he controller to the drives Dual domain SAS implementations make it possible to tolerate host bus adapter HBA or controller failure external cable failure expander failure cable pulls expander failure and failure in a spanned disk JBOD environments Number of Drives P822 supports up to 227 drives Examples 27 internal drives plus eight HP D2700 Disk Enclosures with 25 drives each 227 drives 27 inter...

Page 6: ...ity Expansion shrink array and move array features Online RAID Level Migration change the fault tolerance level of a configured logical drive Online Stripe Size Migration change the stripe size of a configured logical drive Online Spares provide automatic drive replace for a failed drive in RAID levels other than RAID 0 User Selectable Expand and Rebuild Priority select the priority of rebuilding ...

Page 7: ...On Line Spare and data is reconstructed automatically DRAM ECC corrects against single bit data and address corruption Ease of Use Consistency and Upgradeability make the Smart Array family unique in the industry GUI based configuration management and diagnostic software tools Common data format between generations of products Data migration between servers and external Modular Smart Array enclosu...

Page 8: ...anagement tool for HP Smart Array the HP Array Configuration Utility ACU For more information please visit www hp com go smartcache Warranty The warranty for this device is 3 years parts only Pre Failure Warranty Drives attached to the Smart Array Controller and monitored under Insight Manager are supported by a Pre Failure replacement Warranty For complete details consult the HP Support Center or...

Page 9: ... Systems Insight Manager SIM Provides the basic management features of system discovery and identification single event view inventory data collection and reporting Monitors over 1200 system wide parameters Smart Array performance monitoring Smart Array drive fault prediction HP Array Configuration Utility ACU Powerful Web based configuration utility for all Smart Array controllers Provides a grap...

Page 10: ... splitting is a task that splits an array with one or more RAID 1 or RAID 1 0 logical drives into two identical new arrays with RAID 0 logical drives This is useful for administrators who want to replicate a configuration or need to build a backup before performing a risky operation Using the ACU administrators can also recombine a split mirrored array Drive Erase completely erases physical disks ...

Page 11: ...ice solution HP can work with you to tailor a service solution for your unique support requirements using broader services portfolio of Foundation Care and Proactive Care Recommended HP Care Pack Services for optimal satisfaction with your HP product Recommended Services 3 Year HP 24x7 4 hour Response Proactive Care Helps optimize your systems and delivers high levels of application availability t...

Page 12: ... months http h20195 www2 hp com V2 GetPDF aspx 4AA2 3842ENN pdf Insight Remote Support Provides 24 X 7 remote monitoring proactive notifications and problem resolution Learn more http www hp com go insightremotesupport HP Support Center Personalized online support portal with access to information tools and experts to support HP business products Submit support cases online chat with HP experts ac...

Page 13: ...lies only to Disk or eligible SSD Flash Drives replaced by HP due to malfunction It does not apply to any exchange of Disk or SSD Flash Drives that have not failed SSD Flash Drives that are specified by HP as consumable parts and or that have exceeded maximum supported lifetime and or the maximum usage limit as set forth in the manufacturer s operating manual or the technical data sheet are not el...

Page 14: ...TB 6G SAS 7 2K rpm LFF 3 5 inch SC Midline 1yr Warranty Hard Drive 652757 B21 HP 1TB 6G SAS 7 2K rpm LFF 3 5 inch SC Midline 1yr Warranty Hard Drive 652753 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 12244_na 12244_na html HP 6G SATA Hard Drives 6G SATA Hot Plug with SmartDrive SFF 2 5 inch Midline MDL Drive...

Page 15: ...18183 B21 HP 240GB 6G SATA Value Endurance LFF 3 5 in SC Enterprise Value 3yr Wty Solid State Drive 718177 B21 6G SATA ME Hot Plug SFF 2 5 inch Enterprise Mainstream Solid State Drives HP 800GB 6G SATA Mainstream Endurance SFF 2 5 in SC Enterprise Mainstream 3yr Wty Solid State Drive 691868 B21 HP 400GB 6G SATA Mainstream Endurance SFF 2 5 in SC Enterprise Mainstream 3yr Wty Solid State Drive 6918...

Page 16: ... SC Enterprise Mainstream 3yr Warranty Solid State Drive 653126 B21 HP 200GB 3G SATA MLC LFF 3 5 inch SC Enterprise Mainstream 3yr Warranty Solid State Drive 653124 B21 HP 100GB 3G SATA MLC LFF 3 5 inch SC Enterprise Mainstream 3yr Warranty Solid State Drive 653122 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs...

Page 17: ...p com products quickspecs 13404_na 13404_na html Tape Storage SAS Tape Drives HP StoreEver DAT 160 SAS Internal Tape Drive Q1587A HP StoreEver DAT 160 SAS External Tape Drive Q1588A HP DAT 320 SAS Internal Tape Drive AJ830A HP DAT 320 SAS External Tape Drive AJ828A HP StoreEver LTO 2 Ultrium 448 SAS Internal Tape Drive DW085A HP StoreEver LTO 2 Ultrium 448 SAS External Drive DW086A HP Ultrium 920 ...

Page 18: ...e drive SFF8482 port AP746A HP SAS Min Min 1x 2M Cable Assembly Kit NOTE Use this cable to connect HP SAS external tape devices to HP SAS controllers with external Mini SAS SFF8088 connectors AE470A HP SAS MIN MIN 1X 4M Cable Assembly Kit NOTE Use this cable to connect HP SAS external tape devices to HP SAS controllers with external Mini SAS SFF8088 connectors AE465A HP SAS MIN MIN 3X1X 5M Cable A...

Page 19: ... 0 Striping Mirroring RAID 5 Distributed Data Guarding RAID 6 Advanced Data Guarding RAID 50 RAID 60 RAID 1 ADM Advanced Data Mirroring Upgradeable Firmware Flashable ROM with redundant firmware images Environment friendly Products and Approach End of life Management and Recycling Hewlett Packard offers end of life HP product return trade in and recycling programs in many geographic areas For trad...

Page 20: ...HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein For hard drives 1GB 1 billion bytes Actual formatted capacity is less QuickSpecs HP Smart Array P822 Controller Technical Spe...