background image

Wired Controller 

Operation & Installation Manual 

 

Please read this operation manual before using the air conditioner. 

 

Please keep this manual carefully and safely.

YR-E20

CONTENT

Wired Controller Instruction ................................................ 1
Wired Controller Function  .................................................. 7
Wired Controller Wiring Connection ................................. 35

ENGLISH

中文

Summary of Contents for YR-E20

Page 1: ...Manual Please read this operation manual before using the air conditioner Please keep this manual carefully and safely YR E20 CONTENT Wired Controller Instruction 1 Wired Controller Function 7 Wired Controller Wiring Connection 35 ENGLISH 中文 ...

Page 2: ...1 Wired Controller Instruction Interface Display ...

Page 3: ... 30 C If energy saving mode is set the lowest temperature limit of cooling dry and the highest temperature limit of heating are decided by the setting of energy saving parameter The default setting data is 23 C to be lowest temperature in cooling dry mode and 26 C to be highest temperature in heating mode Note The wired controller shows the ambient temperature if the dip switch SW2 is ON The contr...

Page 4: ...ng fan dry intelligent Note No heating mode for cooling only unit or if communication is abnormal Fan speed key press this key to adjust fan speed Function key it is used for clock setting timer swing fresh health electrical heating sleeping energy saving turbo quiet function etc ...

Page 5: ...splay When the ambient temp is displayed on the wired controller the thermometer on the top left corner will display accordingly Set the controller shows this icon when setting the energy saving data temperature compensation data Error this icon appears when communication error happens or indoor unit meets error This icon disappears after the error is solved Swing this icon is displayed dynamicall...

Page 6: ...ping is set The sleeping time is displayed when the function cycle shift to sleeping Energy saving Quiet Turbo this function is invalid after sleeping is set The function will be canceled if you set sleeping mode after turbo mode Lock this icon is displayed after lock signal is received from communication Operation is invalid after the wired controller is locked Defrost ...

Page 7: ...6 dFg Only valid for part of models Child lock this icon is displayed only after you set child lock or it will not display Intelligent mode Cooling mode Heating mode Fan mode Dry mode ...

Page 8: ...re no display OFF SW3 Room temperature sensor on PCB is valid Room temperature sensor on wired controller is valid OFF SW4 Function cycle simple version Function cycle general version OFF SW5 Old Protocol Selfadaption OFF SW6 Reserved Reserved OFF SW7 No swing Swing OFF SW8 Electrical heating is started manually Electrical heating is started automatically OFF ...

Page 9: ...hild lock 1 Set the child lock after the buzzer sounds 7 times cancel child lock after the buzzer sounds 2 times 2 Child lock can also be set by keep pressing fan speed key and function key for 5s together These two ways can be used mutually to set or cancel the child lock 3 The function key can unlock the child lock only under child lock mode The buzzer can sound once you press the function key b...

Page 10: ... changes to be the limit lowest temperature if energy saving is set To enter rated cooling mode after the buzzer sounds 5 times Unit is on heating mode 30 C high speed function 8 times 30 C changes to be the limit highest temperature if energy saving is set To enter rated heating mode after the buzzer sounds 5 times Initialization 1 After power on initialization finishes after wired controller int...

Page 11: ...ting function it will recover to screen saving time before adjustment and start up the unit 4 Switch on the unit the backlight is burning Switch off the unit the backlight is off The leaf icon is on after switching on the unit whatever backlight is on off The leaf icon is off after unit is off 5 For the convenience of adjusting clock the backlight is on if wired controller is off after powering on...

Page 12: ...tion key to confirm the adjustment No pressing of function key or no adjustment for 10 seconds the clock will back to the previous station 2 Press up down key the clock will increase or decrease 1 minute once Keep pressing the up down key the clock can be adjusted more quickly It will quit the function circulation after confirm the clock adjustment or no operation for 10 seconds 3 The clock range ...

Page 13: ...and timer icon display statically on the screen Timer 1 Timer mode timer on timer off timer on off 2 Time precision 1 minute 1 hour Timer clock is based on the current clock time when timer clock is over the timer icon disappears and execute the timer function 3 Timer on off timer can be set whenever unit is on off The controller show the timer icon and time whenever the unit is on off if you set ...

Page 14: ...it displays default 12 00PM for the first time previous setting will be displayed if there is setting before Then hour position and ON are flashing Press fan speed key again the minute position and ON are flashing Press fan speed key again it displays default 12 00PM for the first time previous setting will be displayed if there is setting before Then the hour position and OFF are flashing Press f...

Page 15: ... the clock The clock icon and time will display statically If there is no pressing of up down fan mode or function key for 10 seconds it will quit clock checking It will display previously timer and if press ON OFF key it will quit clock checking and execute turning on off unit operation flashing Press fan speed key again then the hour and OFF are flashing Press up down key to adjust the time minu...

Page 16: ...ng is independent which can be executed separately but sleeping will be cancelled after turning off the wired controller When timer on is the same with the sleeping time the last setting will not be confirmed If there is no changing operation and no key pressing for 10 seconds it will quit the last setting and setting invalid Fan speed Wired controller can execute 3 or 7 fan speeds which is determ...

Page 17: ...n is valid only SW7 is OFF it will not in the function cycle if SW7 is ON 2 7 fan speeds Press fan speed is changed in cycle seventh fan speed sixth fan speed fifth fan speed fourth fan speed third fan speed second fan speed first fan speed AUTO seventh fan speed seventh fan speed sixth fan speed fifth fan speed fourth fan speed third fan speed second fan speed first fan speed Note AUTO fan is cha...

Page 18: ...to set other function like sleep function you need to press function key again to enter function circulation The Left Right swing can be adjusted Press function key to enter function circulation the Left Right icon will flash then press the function key again the angle of the Left Right swing will flash if powered on for the first time the default angle is in position 1 the middle position of Left...

Page 19: ...e final adjusted angle In the adjustment process pressing the ON OFF key to power off the wired controller directly and swing angle is the final adjusted swing angle Fresh 1 Choose fresh by function and up down keys when the icon flashes press function key to confirm then the icon displays statically Do same operation again to cancel fresh function 2 After you set fresh it is switched off together...

Page 20: ...controller is switched on again with heating mode or changing to heating mode again electrical heating function will switch on automatically again The electrical heating will be activated manually if SW8 is ON When electrical heating is set it will be kept once the wired controller is switched on again but not kept with mode changing 3 Under intelligent mode heating running wired controller receiv...

Page 21: ... function by function and up down keys then press function key to confirm 8h is displayed 8 hour is default or others if you ever set it You can adjust the time by up down keys The range is 1h 8h after adjustment press function key again to confirm this setting The sleeping time disappears after 3 seconds Then the set temperature ambient temperature is displayed You need shift to the sleeping func...

Page 22: ...he prior one You cannot use turbo function during sleeping time 3 You can find turbo quiet in function cycle only under cooling heating mode and SW4 is OFF They will be cancelled after any mode change operation and on off operation ECO 1 Press function key to enter function setting then press up down key to choose energy saving press function key again to confirm the operation and display energy s...

Page 23: ...en energy saving function is set its highest limit value of Fahrenheit will be displayed 2 If the current temp is displayed in Fahrenheit set temp should be adjusted to 60 F in each mode when energy saving function is set currently the cooling dry mode will be the lowest limit value of the energy saving function Then press key for 15s to switch to Celsius the interface will display 16 C when energ...

Page 24: ...ashing press function key again self cleaning function is successfully canceled The indoor unit will quit after executive the self cleaning function 2 There is remote control receiver in wired controller self cleaning function can also be canceled by remote controller 3 Self cleaning function will be canceled after pressing ON OFF key or mode key receiving ON OFF or mode change signal from remote ...

Page 25: ... temp displaying area will display b without displaying temp and sleeping time motion sensing 1 Motion sensing A means following people after setting of motion sensing A A will disappear and it will display ambient set temp normally and the motion sensing icon will display statically 2 Motion sensing B means avoiding people after setting of motion sensing B b will disappear and it will display amb...

Page 26: ...irflow function again motion sensing becomes invalid and motion sensing icon disappears 2 Four way cassette In on state press function key to display four way cassette icon and up down swing icon 1 3 2 4 1 First powering on the initial position of respective mode Intelligent Heating Cooling Dry Fan Four way swing All display All display All display All display All display Swing angle Position 3 Po...

Page 27: ... key to select swing type the selected blade will flashing press up down key to adjust swing angle If pressing mode or fan key in the adjustment it will quit four way cassette adjustment and display the last set swing blade position and angle If there is no operation of up down key for 5s after pressing function key the selected swing blade will stop flashing and return to the previous state 3 Swi...

Page 28: ... swing blade and up down angle before entering the health airflow Press up down key in 5s to adjust swing angle and quit health airflow if there is no pressing of up down key for 5s resume health airflow display 1s display 1s display 1s display 1s display 1s 4 The initial entering default position after powering on is as above mentioned and the swing angle will in circulation by up down key from d...

Page 29: ...hange ECO data by up down key and press function key to confirm It is available under cooling and dry mode 2 Unit on heating 16 C keep pressing fan down keys for 5 seconds ECO parameter is displayed on top left corner and the setting icon statically displays 26 C is the default data in heating mode This is to say the target heating temperature is from 16 Cto 26 C You can change this ECO data by up...

Page 30: ...splay current error again 3 Press any key to quit the error inquiry state Wired controller will quit the error inquiry state or error cleaning state if no operation for 10 seconds 4 If there is communication error between wired controller and indoor unit wired controller will display E8 and error icon Wired controller can be operated normally and display the set temperature when adjusting If there...

Page 31: ...ancel this function once power failure happens the wired controller is off state after power comes back The running mode is intelligent mode auto fan speed 24 C If you set non volatile memory and timer or sleeping function the wired controller enters off state after power failure then enters the previous state Matching Central Controller 130 The controller displays when the indoor unit send lock s...

Page 32: ...is valid Forced Cooling Press ON OFF key within 5 s in off state to turn on the unit with buzzer buzzing 2 times Keep pressing ON OFF key for 5 seconds the buzzer sounds 2 times The unit enters forced cooling mode then the state is on cooling mode 16 C high speed LL is displayed instead of set ambient temperature and LL is flashing Press any key or receive remote signals to exit the forced cooling...

Page 33: ...ating high speed 30 C if energy saving mode is set it is the limit highest temperature and press function key 8 times in 5 seconds to enter rated heating mode after the buzzer sounds 5 times the state is high speed and standard heating swing The unit will exit the rated heating mode when receiving the new command through remote or manual signal Ambient Temperature Display 1 The set temperature is ...

Page 34: ...controller receives the signal but the interface will not display the function that controller doesn t have The sounds of buzzer are the same with controller setting automatically The buzzer does not sound if the wired controller fails to receive the signal When wired controller and remote controller are in the same on off state and the controller receives non correct mode signal from remote contr...

Page 35: ...irculation use or key to switch between different functions When it switch to the icon flashes press MENU key to turn on or turn off the dFg function meanwhile return to the main interface Parameters Screen shows PM2 5 P digital Formaldehyde F digital TVOC V digital CO2 C digital Humidity S digital The numerical of PM2 5 CO2 and Humidity are all integer TVOC and Formaldehyde are all decimal Colon ...

Page 36: ...35 1 Pull the communication wire though the hole of back cover press this clip to open the wired back cover base box Wired Controller Wiring Connection ...

Page 37: ... wired controller to back cover Finish the installation D C B A A B C D A B C Please connect the red terminal of communication wire to indoor unit PCB There is a shielded wire at the red terminal part which should be linked to indoor unit ground wire Wired Controller terminal white yellow yellow red red green green ...

Page 38: ......

Page 39: ...线控器 使用安装说明书 使用前请仔细阅读本说明书 阅后请妥善保存 售后服务热线 4006 999 999 YR E20 目录 线控器说明 1 线控器功能说明 5 线控器接线说明 27 ...

Page 40: ...1 线控器说明 界面显示 ...

Page 41: ...功能 温度调整上下限为 16 到 30 若设置节能功能 则制冷 除湿模式 时温度调节下限和制热模式时温度调节上限以节能 参数的设置为准 出厂默认制冷 除湿模式 23 制热模式 26 注 若当前拨码 SW2 为 ON 即显示环温 则关 机状态下 温度区显示环温 从关机 开机 切换 模式 调整设定温度等情况时 会静态显示设定温 度 3 秒钟 3 秒后静态显示环温 模式调整键 按此按键 模式按照 智能 制冷 制热 送风 除湿 智能 循环切换 注 单冷机型或者通讯异常时无制热模式 风速调整键 按风速键 调节风速 功能键 用来设定时钟 定时 摆风 新风 健康 电加热 睡眠 节能 强力 安静等功能 ...

Page 42: ...定时开 定时关 定时开 关 温度显示区 精确到 0 5 若为整数 则 显示如 25 0 温度补偿参数显示 睡眠 时间显示 当线控器设置显示环温时 左上 角的温度计图标会跟随显示 设置 设置节能参数 温度补偿参数的同时 显示设置图标 故障 当出现通讯故障以及室内机故障时 显示此图标 故障消除后 图标消失 摆风图标 若有摆风 此图标动态显示 未 设置摆风功能 此图标无 滤网清洗标志 新风 当设置新风功能时 显示此图标 未 设置新风功能 此图标无 电加热 健康 ...

Page 43: ...4 睡眠 若设置睡眠 显示此图标 当再次功能设定循 环到睡眠时 温度区域显示已设定的睡眠时间 节能 安静 强力 睡眠设定后 不能设定强力功能 强力功能设 定后 再设置睡眠功能 强力功能取消 锁定 当通讯传递锁定命令时 显示此图标 线控器 按键被锁定 操作无效 除霜 多风感 部分机型适用 童锁 若设置童锁 显示此图标 若无童锁 无此图标 智能模式 制冷模式 制热模式 送风模式 除湿模式 ...

Page 44: ...W1 变频机型 定频机型 OFF SW2 环温显示 环温不显示 OFF SW3 采集电脑板环温 采集线控器环温 OFF SW4 功能循环简约版 功能循环普通版 OFF SW5 固定老协议 新老协议自适应 OFF SW6 预留 预留 OFF SW7 无摆风 有摆风 OFF SW8 电加热手动开启 电加热自动开启 OFF 特殊功能的设置 5 秒内连续操作功能键 设置功能 开机 功能键 10 下 蜂鸣器回响 4 声 设置 掉电记忆 蜂鸣器回响 2 声 取消 掉电记忆 ...

Page 45: ...互 设置相互取消 3 童锁下 功能键只是用来解除童 锁 按功能键有按键响应 但不 响应功能对应图标 关机 功能键 10 下 蜂鸣器回响 3 声 温度区显环温持 续 5 秒 拨码选择不显示环温时 即拨码 SW2 为 OFF 时 开机 制热 30 高 速 功能键 6 下 如果 设置了节能 30 改为制 热最高温度 蜂鸣器回响 3 声 线控器向内机下 发 强制除霜 指令 除霜图标闪 烁 3 下后消失 开机 制冷 高速 16 若有节能 按照 节能限制的最低温度 按功能键 8 次 蜂鸣器回响 5 声 进入额定制冷运 转模式 开机 制热 高速 30 若有节能 按照 节能限制的最高温度 按功能键 8 次 蜂鸣器回响 5 声 进入额定制热运 转模式 ...

Page 46: ...键对屏保时间进行调节 按功能键确定 2 屏保时间为 0s 开机背光一直点亮 15s 30s 60s 默 认值为 15s 非首次进入 若上次更改 则显示上次更改后 的屏保时间 3 屏保时间更改过程中 按开关机键 退出屏保时间设置功能 屏保时间恢复调整前状态 同时执行开机动作 4 开机 背光点亮 关机 背光关掉 开机时 树叶图标亮 无 论背光是否点亮 关机后 树叶图标熄灭 5 为了便于用户调整时钟 当线控器上电后为关机状态时 背 光灯亮 当开机再关机时 背光正常关闭 6 当线控器处于关机状态时 按除开关键的任意键仅是触发点 亮背光 不执行按键响应操作 当按开关键时 背光点亮并 同时执行开机动作 当线控器处于开机状态并已处于屏幕保 护时 按所有按键均为解除屏幕保护 不下发按键指令 初始化 屏幕保护 ...

Page 47: ...按上下键 时钟以 1 分钟为单位变化 上下 键按住不放时 1 秒钟后变化 2 次 秒 5 秒钟后变化 10 次 秒 10 秒后以 10 分钟为单位变化 频率为 10 次 秒 无 论时钟调整确认还是 10 秒后未操作退出时钟调整 都直接 退出功能循环 3 时钟显示范围 12 00AM 至 11 59AM 12 00AM 指凌 晨 00 点 12 00PM 至 11 59PM 12 00PM 指正午 12 点 默认时间为 12 00PM 4 设定定时 睡眠后 时钟不可调 按功能键 时钟不参与循环 时钟功能 7 关机状态下 显示时钟 环温 当SW2为ON 即显示环温时 定时时间 若设置了定时 以及新风图标 仅在关机情况下 设定新风功能时显示 关机状态下 可进行时钟 定时 新风 童锁 温度补偿参数调整 环温显示的设定 ...

Page 48: ...整到定时功能 闪烁 再按功能键进入定时时间调整状态 定时图标固定 显示 设置定时开 显示默认 12 00PM 若设置过定时开 则 显示上次定时开设定时间 ON 和时间的小时位闪烁 通过上下键调整时间 长按可加速 加速方法同时钟 通 过风速键 切换到 ON 和时间的分钟位 调整完成后 按 功能键确定 定时开时间及图标固定显示在界面上 设置定时关 显示默认 12 00PM 若设置过定时开 则 显示上次定时开设定时间 ON 和时间的小时位闪烁 通 过风速键 切换到 ON 和时间的分钟位 再次按风速键切 换到 OFF 和时间的小时位闪烁 时间显示默认的定时关 时间为 12 00PM 若设置过定时关 则显示上次定时关 设定时间 通过上下键调整时间 通过风速键 切换到 OFF 和时间的分钟位闪烁 调整完成后 按功能键确定 定时关时间及图标固定显示在界面上 ...

Page 49: ... ON 和 OFF 同时显示 但 ON 和时间的小时位闪烁 设置定时开 关的开的小时 位 再次按风速键 ON 和时间的分钟位闪烁 设置定 时开 关的开的分钟位 再次按风速键 OFF 和时间的 小时位闪烁 设置定时开 关的关的小时位 再次按风速 键 OFF 和时间的分钟位闪烁 设置定时开 关的关的 分钟位 调整完成后按功能键 定时开关时间及图标固定 显示在界面上 ON OFF 的箭头方向根据设置的时间自 行判定显示 箭头由先执行的操作指向后执行的操作 如 ON OFF 即先执行定时开后执行定时关 取消定时功能 当定时功能设定中时 按模式键或关机键 可直接退出定时设定 系统恢复设定前状态 当按模式键 时 仅退出 当按开关机键退出的同时执行开关机动作 当定时功能已设定时 按照上述设定定时开关的步骤 当 按风速键切换到定时开关的定时关分钟位时 再按一次 定时功能取消 ...

Page 50: ...时钟查看状态并 直接执行开关机动作 定时时间设定要求 所设定时时间与当前的时钟相同以及 定时开与定时关时间相同时 按功能键不能完成确定 保 持当前状态 但蜂鸣器正常发声 若不更改时间 10 秒 内无按键操作后自动退出 此次设置无效 定时与睡眠关系 定时开关与睡眠相独立 互不干扰 时 间到即执行相应动作 但关机后睡眠设定也同时取消 定 时开时间和睡眠执行的时间相同时 无论定时开和睡眠设 置的先后 后设置的不能设置成功 一直为闪烁待确认状 态 10 秒内无操作 则退出当前设置 风速 线控器可执行三档风速和七档风速 该功能主要决定于内机 部分机型适用 1 3 档风速 按 键 风速按照 自动 低速 中速 高速 自 动 循环切换 风速图标显示 低速 中速 高速 ...

Page 51: ...设置此功能 摆风动态显示 若已经设置 摆风功能 进行上述操作 摆风功能取消 同时界面上取消 摆风图标 2 当 SW7 为 OFF 时摆风参与功能循环 SW7 为 ON 时摆风 不参与功能循环 2 7 档风速 按 键 风速按照 7 档 6 档 5 档 4 档 3 档 2 档 1 档 自动 7 档 其中 1 档风为最高风速 风速图标显示 7 档 6 档 5 档 4 档 3 档 2 档 1 档 备注 自动风按照 低速 中速 高速 低速 循环显示 小风扇下方显示 AUTO 送风模式下无自动风 ...

Page 52: ...角度显示 若要设置其他功能 如 睡眠等功能 则需再次按功能键进行功能循环 左右摆风角度可调节 按功能键进入功能循环 上下摆风图标闪烁显示 此时按上 下键切换至左右摆风图标闪烁显示 再次按功能键 此时左 右摆风的当前摆风角度闪烁显示 首次上电 摆风角度 1 非 首次上电为上次调节的摆风角度 此时通过上下键对摆风 角度进行循环调节 按上下键调节摆风角度 按键即发码 连续 10s 无按键操作 则退出摆风功能的同时退出功能循环 此时摆风按最后一次调节的摆风角度显示 若要设置其他功 能 如上下摆风等功能 需再次按功能键进入功能循环 摆风功能的退出 按风速键 模式键均可退出摆风角度调节功能 调节摆风角 度后 按功能键立即退出摆风功能 调节过程中 连续 10s 无按键操作退出摆风功能 摆风角度按最后调节的摆风角度 执行 摆风角度调节过程中 按开关机键直接执行关机动作 摆风角度按最后调节的摆风角度执行 ...

Page 53: ...控器开机 新风功能保持 设置新风功能后 切换模式时 新风功能保持 3 新风功能仅在 SW4 为 OFF 时 参与功能循环 当 SW4 为 ON 时不参与 新风 当界面显示 滤网清洗 标志后 功能循环时 参与循环 在滤网图标闪烁状态下 按功能键进行滤网标志的清除 滤网 1 按下功能键 上下键循环到 时 再次按功能键 可以对 电加热功能进行设定和取消 电加热仅在制热模式或智能模 式制热运行时参与功能循环 2 当 SW8 为 OFF 时 制热模式下自动开启电加热 显示电 加热图标 自动开启后 可以通过手动取消 取消后 如果 重新开机为制热 或者切换到其他模式再次循环到制热模式 时 电加热自动开启 当 SW8 为 ON 时 则制热模式下电 加热需要手动开启 设定电加热后 线控器开关机记忆 模 式循环不记忆 电加热 ...

Page 54: ...制热状态下 线控器收到主板发送的制热状态判 断当前为制热运行 电加热参与功能循环 如果是智能模式 非制热状态 电加热不参与循环 4 关机状态下 不进行电加热的循环 睡眠 1 按下功能键 通过上下键切换到 闪烁时 再次按功能键 此时温度显示区显示 8h 默认为 8h 非首次设定显示上次 设定的睡眠时间 通过上下键可调整睡眠时间 调整范围 为 1h 8h 调整后 再次按功能键确认 睡眠时间显示 3 秒 后消失 温度区正常显示设定温度 环境温度 设定后若想 查看已设定的睡眠时间 需按功能键调整到睡眠功能时 温 度区自动显示已设定时间 若已经设置了睡眠功能 进行上 述操作 则为睡眠功能的取消 2 睡眠功能仅在 SW4 为 OFF 时参与功能循环 当 SW4 为 ON 时不参与 ...

Page 55: ...睡眠时 不能设定强力 功能循环时 强力图标不参与循环 设定强 力后 再设定睡眠 确定后 强力功能取消 3 仅在制冷 制热模式下参与功能循环 模式切换时不记忆 开关机不记忆 无论线控器是否有掉电记忆 掉电后强力安 静均不记忆 强力 安静功能仅在 SW4 为 OFF 时参与功能 循环 当 SW4 为 ON 时不参与 节能 1 按下功能键 通过上下键切换到 闪烁时 再次按功能键 设定节能功能 若已经设定了节能功能 进行上述操作 为 节能功能的取消 2 线控器关机状态时不进行节能图标的显示和设置 节能功能 属于底层设置 无论线控器有无掉电记忆 掉电后均记忆 无论节能参数如何设置 按功能键设置节能后 节能图标均 显示 也参与功能循环 节能功能在所有模式下都可以设定 但是节能功能仅在制冷 制热 除湿模式下有效 3 节能功能仅在 SW4 为 OFF 时参与功能循环 当 SW4 为 ON 时不参与 ...

Page 56: ...功能 则制冷 除湿模式为节能功能 的下限值 此时长按下键持续 15s 切换至摄氏 界面显示 16 若设置节能功能 则显示节能功能的摄氏下限值 自清洁功能 1 设置方式 1 按功能键进入功能循环 上下键切换到 CL 闪烁时 按功 能键自清洁功能设置成功 界面静止显示 CL 2 线控器有遥控器接收头 可接收遥控器设置的自清洁功能 2 取消方式 1 按功能键进入功能循环 上下键切换到 CL 闪烁时 按功 能键自清洁功能取消成功 内机执行完自清洁功能自动退 出 2 线控器有遥控器接收头 可接收遥控器取消自清洁功能 3 线控器按开关机键 更改模式 或者接收遥控器开关机 模式更改 执行按键操作 同时退出自清洁功能 3 睡眠 定时功能设置后 功能循环中不循环自清洁功能 自 清洁功能设置后 定时 睡眠功能不参与功能循环 ...

Page 57: ... 8 字段显示 A 此时不显示温 度和睡眠时间 人感 B 中间温度显示区第二个 8 字段显 示 b 此时不显示温度和睡眠时间 人感 1 人感 A 表示跟随人 人感 A 设置完成后 字符 A 取消 正常显示环温 设定温度 人感图标静止显示 2 人感 B 表示避开人 人感 B 设置完成后 字符 b 取消 正常显示环温 设定温度 人感图标闪烁 3 人感设置完成后 人感图标进行显示2s 消失2s循环显示 4 人感 A 人感 B 人感功能也可通过遥控器设定 开关机 记忆 掉电记忆 切换模式时保持 5 此功能仅在内机回复为四面嵌机型时有效 6 人感设定后 四面嵌角度 健康气流功能无效 若重新调 整四面嵌角度 设定健康气流功能 人感功能取消 图标 消失 ...

Page 58: ...位置 3 位置 5 位置 3 位置 3 位置 3 2 开机后 通过点按功能键进行切换导风板 按照如下循环 四面嵌四面同控 四面嵌 1 四面嵌 2 四面嵌 3 四 面嵌 4 四面嵌四面同控循环 非首次进入 按功能键 显示最后一次设置的导风板位置且闪烁 同时右侧的上 下摆风处显示此导风板最后一次设置的摆风角度 3 按功能键选择摆风类型时 被选择的导风板闪烁 此时 按上下键调整导风板角度 如果调整过程中按模式或者 风速键 则退出四面嵌调整 固定显示最后一次导风板 位置和相应角度 如果点按功能键后连续 5 秒没有进行 上下键按键操作 被选择的导风板停止闪烁 回到调整 前状态 1 3 2 4 ...

Page 59: ... 示 4 开机后首次进入摆风默认角度如 1 表中所述 摆风角度 从默认位置通过上下键进行循环 比如当前在角度 3 按上 键到角度 2 按下键到角度 4 若非首次进入 摆风角度从 上次调整后的角度开始循环 4 健康气流 此功能仅通过遥控器设定 设定后模式切换时保持记忆 开 关机不记忆 不进行掉电记忆 设定后液晶上四面嵌摆风图 标上的每个摆风循环交替显示 见下图 表示摆风以旋转 出风方式出风 同时 上下摆风角度显示自动摆 健康气流下 按动功能键 界面相应显示进入健康气流之前的导风板位置 和相应导风板的角度 5s 内按摆风角度键调整角度的同时退 出健康气流 如果 5s 内没有按动上下键 恢复健康气流状态 显示 1s 显示 1s 显示 1s 显示 1s 显示 1s ...

Page 60: ...查询状态下 按任意键退出查询状态 当进入故障查询 状态或清除故障时 10 秒钟未进行按键操作 自动退出查询 或清除故障状态 节能参数设定 1 开机 制冷模式 30 条件下 长按风速键 上键持续 5 秒 则在左上角前两个 88 处 显示制冷节能参数 并显示设置 图标 默认值为 23 即设置节能后制冷和除湿模式的 温度调整范围为 23 30 制冷节能参数可以通过上下键进 行调整 通过功能键确定 仅在制冷和除湿模式下有效 2 开机 制热模式 16 条件下 长按风速键 下键持续 5 秒 则在左上角前两个 88 处显示制热节能参数 并显示设置图 标 默认值为 26 即设置节能后制热模式的温度调整 范围为 16 26 制热节能参数可以通过上下键进行调整 通过功能键进行确定 仅在制热模式下有效 3 如果设定节能功能后 设置进入强制制冷 强制过程中发码 为 16 退出强制制冷后 回到节能的限制温度 ...

Page 61: ...度时 显示设定的温度 3 秒内无按键操作后温度显示区再次显示 E8 若通讯恢复 故障自动解除 童锁 配套集中控制器 130 1 为防止误操作 可以使用键盘锁定功能 同时按风速键和功 能键持续 5 秒 界面显示童锁小图标 设置后除功能键 外其它按键不可用 功能键可用于解除童锁 童锁状态下 进行上述动作为取消童锁 2 同时按风速键和功能键持续 5 秒与 5 秒内连续按功能键 12 下和 4 下设置和取消童锁功能为或的关系 可相互作用 当收到内机远程锁定 状态 非指令 为 1 则显示 所有 按键不可用 也不接受遥控器信号 ...

Page 62: ... 在 5 秒内连续按动功能键 10 次 蜂鸣器连响 2 声 取消掉电记忆功能 系统所有运行状态不 再记忆 掉电后再上电 线控器处于关机状态 开机后为智 能模式 自动风 24 在设定掉电记忆后 如果掉电前设 定定时或者睡眠 那么上电后线控器先进入关机状态 按开 关机键进入关机前的状态 2 掉电记忆功能设定后 若线控器 EEPROM 损坏 线控器自 动按无掉电记忆状态运行 3 故障 节能参数和节能使能位 温度补偿为底层参数 无论 有无掉电记忆 均记忆 1 关机非屏保状态下 长按风速键持续 10 秒 温度区显示温度 补偿值 并显示设置图标 默认值为 00 当选择摄氏度时 补偿值调整范围为 4 至 4 当选择华氏度时 补偿值调整 范围为 7 至 7 调整温度补偿值后按功能键确定 2 温度补偿值仅在采集线控器环温时有效 即拨码 SW3 为 OFF ...

Page 63: ...定频率 闪烁 通讯里发强制制冷标志 按任意键或接收遥控器信号 退出强制制冷并发码 强制制冷 开机状态 制冷 高速 16 如果有节能设置 则按照节能 限制最低温度 5 秒内连续按功能键 8 次 蜂鸣器回响 5 声 进入额定制冷运转模式 风速为高速 摆叶为制冷标准模式 空调器处于额定制冷运转状态中 遥控或按任意键改变当前状 态 主机按照重新设定状态运行 额定制冷运转 开机状态 制热 高速 30 如果有节能设置 则按照节能 限制最高温度 5 秒内连续按功能键 8 次 蜂鸣器回响 5 声 进入额定制热运转模式 风速为高速 摆叶为制热标准模式 空调器处于额定制热运转状态中 遥控或按任意键改变当前状 态 主机按照重新设定状态运行 额定制热运转 ...

Page 64: ...以通过拨码 SW2 设定 当 SW2 为 ON 时 线控器温度区显示环温 强制除霜 在制热 高速 30 若有节能限制 调整到节能上限温度 的条件下 5 秒内连续按功能键 6 次 蜂鸣器连响 3 声 线控 器向主板发送强制除霜信号 闪烁 3 下后取消 红外接收 1 当线控器接收到遥控器发来的信号时 线控器数据更新并显 示设定功能图标 对于线控器不具备的功能 界面不显示 线控器接收成功后 蜂鸣器发声 蜂鸣器响应的方式同线控 器自行设定的时候响声一致 当线控器接收失败时 蜂鸣器 不发声 当线控器和遥控器开关机状态一致时 此时遥控器 向线控器发送非法模式 蜂鸣器回响 3 声 提示接收数据为 非法模式且不接受 2 线控器只接收遥控器 G 码协议信号 ...

Page 65: ...下 多风感 部分机型适用 1 设置方式 按 键 通过 键切换到多风感图标 闪烁时 按 键确定 退回主界面 并开启多风感功能 多风感图标 静止显示 2 取消方式 按 键 通过 键切换到多风感图标 闪烁时 按 键确定 退回主界面 并关闭多风感功能 多风感图标 取消显示 参数 界面显示 PM2 5 P 数值 甲醛 F 数值 TVOC V 数值 CO2 C 数值 湿度 S 数值 PM2 5 CO2 及湿度数值信息均为整数 直接读取即可 而甲醛及 TVOC 数值为小数 冒号代替小数点 3 若当前设置定时功能 优先显示定时功能 ...

Page 66: ...27 线控器接线说明 1 首先将通讯线穿过后盖上的孔位 按此卡扣 开启线控器后盖 暗盒 ...

Page 67: ...28 2 再将后盖固定到暗盒上 然后将通讯线插到线控器的接口 最后将线控器前盖扣到后盖上 安装完成 D C B A A B C D 绿 红 黄 绿 红 黄 A B C 电脑板端子 红色 此端有屏蔽保护线需 接内机地线 线控器端子 白色 ...

Page 68: ...Ver B ...

Reviews: