background image

En-1

INSTALLATION MANUAL

PART NO. 9380228011

AIR CONDITIONER

OPTIONAL PARTS

External connect kit

For authorized service personnel only.

1.  SAFETY PRECAUTIONS

WARNING

This mark indicates procedures which, 

if improperly performed, might lead to 

the death or serious injury of the user.

When installing the wire, please thoroughly read this 

 

manual.
Before installation be sure that all sources of power have 

 

been shut off. There is a danger of electric shock.
For External connect kit and locally purchased parts, 

 

apply voltage indicated on specifications of parts.

 

Application of unspecified voltage may result failure or 

malfunction of air conditioner.

CAUTION

This mark indicates procedures which, 

if improperly performed, might possibly 

result in personal harm to the user, or 

damage to property.

Do not pull on the connectors with too much force.

 

2.  ABOUT THE UNIT

2.1.  General

This external connect kit is an adapter for connecting 

 

outdoor unit control PC board and base heater (local 

wiring) correctly.

 

2.2.  Accessories

The following installation parts are supplied.  

 

Use them as required.

Name and shape

Q’ty

Description

Installation 

manual

1

This manual

Wire

1

For outputting the signal 

of base heater

Contents

1.  SAFETY PRECAUTIONS ................................................ 1

2.1.  General ..................................................................... 1

2.2.  Accessories .............................................................. 1

2.  ABOUT THE UNIT ........................................................... 1
3.  SETTING .......................................................................... 1
4.  CONNECTION METHOD TO OUTDOOR  

CONTROL PC BOARD .................................................... 2

3.  SETTING

Connect the external connect kit  and local wiring referring 

 

to the following wiring method.

The ON/OFF of output signal varies by temperature change.

Operation

Stop

ON

ON

OFF

OFF

Heater status

Temperature

 

4°C (39°F)

Temperature

 

2°C (36°F)

Output signal

Circuit diagram example

1
2
3
4

AC240V

*2

*1

P.C.B

CN206

connected unit

Base heater

Connector

1
2
3
4

AC240V

*3

*1

P.C.B

CN206

connected unit

Base heater

Connector

*1:  Connect to pin 1 and pin 3. No connection pin 2 

and pin 4.

*2: The allowable power consumption is 25W or less.
*3:  If a load greater than 25W is applied, a contactor 

or relay should be used to operate and control the 

base heater.