ETERNUS DX60 S2 

Hardware and Software Installation 

Hardware and Software Installation      ETERNUS DX60 S2 

Summary of Contents for ETERNUS DX60 S2

Page 1: ...0 Copyright Fujitsu Technology Solutions Release September 2011 ETERNUS DX60 S2 Hardware and Software Installation Hardware and Software Installation ETERNUS DX60 S2 ...

Page 2: ...lation Package Contents Rack Mounting Power Cabling Backend Cabling Power On and Power Off Procedures Hardware and Software Installation ETERNUS DX60 S2 Copyright Fujitsu Technology Solutions Release September 2011 1 ...

Page 3: ...sure Kit Installation poster Documentation CD Rack mount kit Controller Enclosure Front bezel 2 X power cord Safety Manual Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 2 ...

Page 4: ...sure Kit Installation poster Rack mount kit Drive Enclosure Front bezel 2 X power cords 2 X SAS cables Safety Manual Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 3 ...

Page 5: ...Rack Mounting 1 Rack mount kit Rack mount installation overview Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 4 ...

Page 6: ... the left hand side slide rail in the 1st and 3rd hole counting from the bottom of the 2U Bracket Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 M5 Centering screws 10 mm 2U Bracket Base line of the Controller Enclosure 5 ...

Page 7: ...ure Secure the left hand side slide rail to the front pillar using the M5 centering screw and M5 pan head screws Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 M5 Centering screw 10 mm M5 Pan head screw 10 mm M5 Cage nut Base line of the Controller Enclosure 6 ...

Page 8: ...g 3 For the right hand side rail insert the pins in the holes of the rear pillar and secure the other side of the slide rail to the front pillar in the same way as with the left slide rail Base line of the Controller Enclosure M5 Cage nut Base line of the Controller Enclosure M5 Pan head screw 10 mm M5 Centering screw 10 mm 7 ...

Page 9: ...Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Rack Mounting 4 Front view of rack installation 8 ...

Page 10: ...lutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Rack Mounting 5 Fit the Controller Enclosure and or Drive Enclosure to the rack For better stability a rack is to be filled starting from the bottom 9 ...

Page 11: ...wer phases Make sure that the AC power switches on each Enclosure are turned off before connecting their power cables Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Always follow the local power cabling regulations 10 ...

Page 12: ...IN and OUT ports and connectors are coded with symbols and are mechanically coded to prevent incorrect cabling SAS IN port connector Plug for SAS IN port SAS OUT port connector Plug for SAS OUT port Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 11 ...

Page 13: ... Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Backend Cabling 1 Connect SAS OUT ports of the Controller Enclosure with the SAS IN ports of the Drive Enclosure 1 3 2 4 12 ...

Page 14: ...s POWER Green when the power is turned on READY Green when the system is available for use FAULT Steady orange when a malfunctioning system component has been detected Blinking orange when a preventive replacement of a system component is required IDENTIFY Blinking blue when turned on from the management software CACHE Steady green when the cache is in use Blinking green when a power failure has o...

Page 15: ...s You can power off also using the ETERNUS Web GUI Select menu Utilities Shutdown Restart System The power supply of the device will shut down in 30 seconds If a reboot is chosen the device will be rebooted after shutdown Before shutting the system down Ask customer to confirm that all Server I O is stopped Check that the CACHE LED on the Operation Panel is off Make sure the CACHE LED of the Contr...

Page 16: ...figuration Initial Configuration Web GUI Initial Configuration for Expansion Drive Enclosure ETERNUS SF Express Hardware and Software Installation ETERNUS DX60 S2 Copyright Fujitsu Technology Solutions Release September 2011 15 ...

Page 17: ... address subnet with the ETERNUS MNT Port for example 192 168 1 2 Connect the LAN port of the computer to the ETERNUS MNT Port Direct connection with normal or crossed cable Web browser Internet Explorer 6 0 7 0 or 8 0 Mozilla Firefox 3 0 x 3 5 x and 3 6 x Web browser settings Do not use a proxy server or cache Temporary Internet Files Enable Java Scripting Style Sheets and Cookies Copyright Fujit...

Page 18: ...oftware Installation ETERNUS DX60 S2 Initial Configuration 2 ETERNUS has one MNT port on each CM but only the port with the green Master LED on is enabled The LAN cable must go to the MNT port with the Master LED on MNT Port CM 0 Master LED CM 0 MNT Port CM 1 Master LED CM 1 17 ...

Page 19: ...e and Software Installation ETERNUS DX60 S2 Initial Configuration Web GUI 1 To start the installation procedure logon to ETERNUS DX60 S2 Web GUI using one of the default User Accounts User name root Password root User name f ce Password Check Code System Serial Number 18 ...

Page 20: ... Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Initial Configuration Web GUI 2 Opening screen after logon to ETERNUS DX60 S2 Web GUI Initial configuration steps General status of the system 19 ...

Page 21: ...aintenance is required for some components Yellow Pinned data is detected Administrator User and General User can not see this status Red This symbol is displayed in the following conditions Component failure is detected Loop Down is detected Red This symbol is displayed in the following conditions Abnormal status is detected at power on Abnormal status is detected at power off the device has not ...

Page 22: ...tus of each component Indicator Color Description Green The component is in normal status Blue Some components are installed but unused For example A disk which is not assigned to a RAID group or as a hot spare Orange The component is under maintenance Yellow Preventive maintenance is required for a component Red A component failure is detected 21 ...

Page 23: ...Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Initial Configuration Web GUI 5 Set Date and Time 22 ...

Page 24: ...Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Initial Configuration Web GUI 6 Set Machine Name optional 23 ...

Page 25: ...Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Initial Configuration Web GUI 7 Change the password if needed need customer approval 24 ...

Page 26: ...Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Initial Configuration Web GUI 8 Set Network Environment if needed 25 ...

Page 27: ...onfigure Expansion Drive Enclosure 1 Choose tab Maintenance Select Add Drive Enclosure Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 26 ...

Page 28: ...yright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Configure Expansion Drive Enclosure 2 This is also a Wizard driven procedure Start with Next 27 ...

Page 29: ... Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Configure Expansion Drive Enclosure 3 This step is to verify that the Drive Enclosure is properly installed in the rack 28 ...

Page 30: ... Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Configure Expansion Drive Enclosures 4 The Software Wizard scans automatically for new Drive Enclosures 29 ...

Page 31: ...ure 5 This step is for verifying that the Auto Power Switch is set to Off The switch is located in the Operation Panel Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 30 ...

Page 32: ...opyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 Configure Expansion Drive Enclosure 6 The Expansion for the Drive Enclosure is finished 31 ...

Page 33: ...ware Installation ETERNUS DX60 S2 End of Initial Configuration Before logging off from the ETERNUS DX60 S2 Web GUI verify that all components have a condition Normal General status of the system in the Web GUI is Normal i e green All system LEDs are showing normal system status 32 ...

Page 34: ...erver ETERNUS SF Express ETERNUS SF AdvancedCopy Manager ETERNUS SF Storage Cruiser DX60 S2 starts shipping with SF Express v14 2 that will be replaced by v15 0 as soon as it becomes available Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 33 ...

Page 35: ...Guide ETERNUS DX60 S2 P2X0 1120 01ENZ0 Link to document ETERNUS DX60 S2 Disk Storage System User s Guide Installation P3AM 5502 02ENZ0 Link to document ETERNUS documentation in Fujitsu PRIMEWEB Link to Fujitsu PRIMEWEB Please note that accessing the above links require a Fujitsu Partner user account Copyright Fujitsu Technology Solutions Release September 2011 Hardware and Software Installation ET...