B442/B443/B444/B444‑A/B444‑V

en

Installation Manual

Summary of Contents for B442

Page 1: ...Conettix Cellular Communicators B442 B443 B444 B444 A B444 V en Installation Manual ...

Page 2: ......

Page 3: ...introduction 4 1 1 About documentation 4 1 2 Bosch Security Systems Inc product manufacturing dates 4 2 Component overview 5 3 Installation 8 3 1 Insert the SIM card 8 3 2 Install the antenna 8 3 3 Install the communicator 10 3 4 Remove the communicator 12 4 Diagnostic LED descriptions 13 5 Configuration 14 5 1 Activating the B444 A B444 V 14 6 Specifications 15 ...

Page 4: ...lows Diagnostic LED descriptions Configuration Specifications 1 1 About documentation Copyright This document is the intellectual property of Bosch Security Systems Inc and is protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly 1 2 Bosch Security Systems Inc produc...

Page 5: ...connecting the communicator into a control panel or into an additional module such as the Conettix Plug in Communicator Interface or the Conettix Universal Dual Path Communicator modules All communicators come with a SIM card holder Communicators with SIM cards 2 3 4 5 6 1 1 Callout Description 1 Module handle and support leg 2 SIM card holder 3 LEDs 4 Threaded female SMA antenna connector 5 Plug ...

Page 6: ...y 6 Plug in module retention clip opening 7 PCM metal contacts Notice Connections to both antenna connectors secondary and primary must be installed using the supplied antennas or an extended antenna sold separately Failure to do so might cause poor signal strength When using an external antenna such as the Bosch Multiband Antenna B40 P B40 MB25 or B40 MB50 connect the cable to the primary connect...

Page 7: ... 04 F 01U 345 070 1 2 3 1 B444 V B444 A cellular module 2 Primary antenna connection port 3 B40 P MB25 MB50 external antenna 1 Connect antenna wire to the B40 P MB25 MB50 antenna port callout 3 2 Connect other end of B40 P MB25 MB50 antenna wire to primary antenna port on B444 V B444 A cellular module callout 2 ...

Page 8: ...away the SIM card from the die cut 2 Insert the SIM card into the SIM card holder by sliding it into the card holder 3 Make sure the gold contact side of the SIM card is against the module Figure 3 1 Inserting the SIM card 3 2 Install the antenna Notice EN certification On the B442 and B443 the length of the antenna cable may not exceed 30 m 98 ft in order to comply with EN certification 1 Put the...

Page 9: ...osch Security Systems B V Installation Manual 2020 02 04 F 01U 345 070 1 2 Figure 3 2 Installing the antenna Callout Description 1 Antenna routed through any knockout 2 Antenna cable connected to the module Figure 3 3 B444 A B444 V antenna installation ...

Page 10: ...ther corner of the enclosure Figure 3 4 B444 A B444 V cable connection 3 3 Install the communicator Control panel universal dual path communicator installation 1 Put the support leg into the support hole labeled X Refer to Figure 3 3 2 Align the PCB metal contacts with the on board connector 3 Push the module into place The retention clip snaps closed and secures the module in place ...

Page 11: ...out Description 1 Support leg inserted into the compatible device support holes 2 PCB metal contacts resting on the on board connector 3 Plug in communicator retention clip Plug in communicator interface installation 1 Insert the communicator into the slot of the plug in communicator interface 2 Push in until you feel it click into place 3 1 2 3 2 Figure 3 6 Communicator installation B450 shown ...

Page 12: ...Bosch Security Systems B V Callout Description 1 SIM card insertion if applicable 2 Communicator 3 Plug in communicator interface 3 4 Remove the communicator 1 Hold the plug in module retention clip open 2 Hold the top corners of the module support handle with your other hand 3 Pull the module out ...

Page 13: ...trength status Signal strength Flash pattern Function Red Indicates an unacceptable signal strength level Yellow Indicates a marginal signal strength level Green 1 light Indicates a good signal strength level Green 2 lights Indicates a very good signal strength level No LED Indicates that the module has not acquired a tower yet Tab 4 1 Signal strength LED descriptions STATUS Flash pattern Function...

Page 14: ...link Configure network alarm communication routes and settings in the control panel Cellular carrier specific settings such as Access Point Name and SIM card security can also be programmed through the control panel or Conettix Plug in Communicator Interface 5 1 Activating the B444 A B444 V The B444 A and B44 V communicator requires a valid Bosch Installer Services account and must be activated wi...

Page 15: ...mmunicators Specifications en 15 Bosch Security Systems B V Installation Manual 2020 02 04 F 01U 345 070 6 Specifications Refer to the communicator graphical installation manuals for communicator specification information ...