background image

Systems | AMC2 4W-EXT - Wiegand Extension Board

The extension module AMC2 4W-EXT is equipped with four
Wiegand type reader-interfaces plus eight inputs and eight
outputs. Hence with the AMC2 4W-EXT it is possible to
double the number of readers on an AMC2 4W from 4 to 8.
The AMC2 4W-EXT can not be deployed as an independent
controller but only as an extension module for the AMC2
4W. Control and access decisions and bookings are carried
out by the AMC2 4W alone.
The AMC2 4W can be extended by a maximum of one
AMC2 4W-EXT plus a maximum of three I/O extension
modules. The I/O extension modules AMC2 8I-8O-EXT,
AMC2 16I-16O-EXT, or AMC2 16I-EXT (in any combination)
are, like the AMC2 4W-EXT, connected via the AMC2 4W’s
extension interface (RS485). As the extension modules
contain neither memory nor display they are controlled and
monitored entirely by the AMC2 4W.

Note

Systems with Access Personal Edition
Software can only connect one I/O-Extension
to an AMC2 Controller.

The signal settings and parametrization of the readers
connected to the extension module, are carried out by the
configuration applications in the access control systems
Access Personal Edition and BIS Access Engine, and by the
AMC2 4W to which it belongs.

System Overview

The AMC2 4W-EXT is connected between the access
controller AMC2 4W and the various peripheral devices.

1 = Host
2 = AMC2 4W
3 = Card reader
4 = Communication and power supply
5 = AMC2 4W-EXT

AMC2 4W-EXT - Wiegand Extension Board

RS485 connection to the AMC2 4W controller

4 Wiegand reader interfaces

8 analog inputs

8 relais outputs (wet or dry)

Status of inputs and outputs shows on AMC2 4W LCD

display

Transfer rate to EXT interface (RS485): 9,6 kBit/sec

www.boschsecurity.com

Summary of Contents for AMC2 4W-EXT

Page 1: ...tension modules contain neither memory nor display they are controlled and monitored entirely by the AMC2 4W Note Systems with Access Personal Edition Software can only connect one I O Extension to an AMC2 Controller The signal settings and parametrization of the readers connected to the extension module are carried out by the configuration applications in the access control systems Access Persona...

Page 2: ... the interface 10 wire interface with shield Max cable length 158 m 172 8 yd 26 bit wiegand format 37 bit wiegand format Default configuration 1 Reader Supply 12V 2 Reader Supply 0V 3 Data 0 4 Data 1 5 Shield 6 green LED 7 red LED 8 Beeper 9 Hold 10 Card Present Contacts Inputs The analog inputs can be used as digital or analog contacts For analog use resistance values can be specified to check fo...

Page 3: ...T Wiegand Extension Board TheextensionmoduleAMC24W EXTisequip ped with four Wiegand type reader interfaces pluseightinputsandeightoutputs Hencewith the AMC2 4W EXT it is possible to double the number of readers on an AMC2 4W from 4 to 8 API AMC2 4WE www boschsecurity com ...

Page 4: ... Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Asia Pacific Robert Bosch SEA Pte Ltd Security Systems 11 Bishan Street 21 Singapore 573943 Phone 65 6258 5511 Fax 65 6571 2698 apr securitysystems bosch com www boschsecurity com Represented by Bosch Security Systems Inc 2010 Data subject to cha...

Reviews: