Chapter 29 Error Disable
XS1930 Series User’s Guide
232
Figure 164
Advanced Application > Errdisable > Errdisable Recovery
The following table describes the labels in this screen.
Table 115 Advanced Application > Errdisable > Errdisable Recovery
LABEL
DESCRIPTION
Active
Select this option to turn on the error-disable recovery function on the Switch.
Reason
This field displays the supported features that allow the Switch to shut down a port or discard
packets on a port according to the feature requirements and what action you configure.
*
Use this row to make the setting the same for all entries. Use this row first and then make
adjustments to each entry if necessary.
Changes in this row are copied to all the entries as soon as you make them.
Timer Status
Select this option to allow the Switch to wait for the specified time interval to activate a port or
allow specific packets on a port, after the error was gone. Deselect this option to turn off this
rule.
Interval
Enter the number of seconds (from 30 to 2592000) for the time interval.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Cancel
Click
Cancel
to begin configuring this screen afresh.