Chapter 30 Error-Disable
XGS1930 Series User’s Guide
240
The following table describes the labels in this screen.
30.5 Error-Disable Detect Configuration
Use this screen to have the Switch detect whether the control packets exceed the rate limit configured
for a port and configure the action to take once the limit is exceeded. Click the
Click Here
link
next to
Errdisable Detect
link in the
Advanced Application
>
Errdisable
screen to display the screen as shown.
Figure 172
Advanced Application > Errdisable > Errdisable Detect
The following table describes the labels in this screen.
Table 116 Advanced Application > Errdisable > CPU protection
LABEL
DESCRIPTION
Reason
Select the type of control packet you want to configure here.
Port
This field displays the port number.
*
Use this row to make the setting the same for all ports. Use this row first and then make
adjustments to each port if necessary.
Changes in this row are copied to all the ports as soon as you make them.
Rate Limit (pkt/s) Enter a number from 0 to 256 to specify how many control packets this port can receive or
transmit per second.
0
means no rate limit.
You can configure the action that the Switch takes when the limit is exceeded.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Cancel
Click
Cancel
to begin configuring this screen afresh.
Table 117 Advanced Application > Errdisable > Errdisable Detect
LABEL
DESCRIPTION
Cause
This field displays the types of control packet that may cause CPU overload.
*
Use this row to make the setting the same for all entries. Use this row first and then make
adjustments to each entry if necessary.
Changes in this row are copied to all the entries as soon as you make them.
Active
Select this option to have the Switch detect if the configured rate limit for a specific control
packet is exceeded and take the action selected below.
Содержание XGS1930-28HP
Страница 19: ...19 PART I User s Guide...
Страница 39: ...39 PART II Technical Reference...
Страница 250: ...XGS1930 Series User s Guide 250 Figure 179 Advanced Application LLDP LLDP Local Status LLDP Local Port Status Detail...
Страница 322: ...Chapter 37 Access Control XGS1930 Series User s Guide 322 Figure 239 Example Lock Denoting a Secure Connection EXAMPLE...
Страница 359: ...359 PART III Troubleshooting and Appendices...