Chapter 33 Error Disable
MES3500 Series User’s Guide
262
Figure 158
Advanced Application > Errdisable > Errdisable Detect
The following table describes the labels in this screen.
33.7 Error-Disable Recovery Configuration
Use this screen to configure the Switch to automatically undo an action after the error is gone. Click
the
Click Here
link
next to
Errdisable Recovery
in the
Advanced Application > Errdisable
screen to display the screen as shown.
Table 117
Advanced Application > Errdisable > Errdisable Detect
LABEL
DESCRIPTION
Cause
This field displays the types of control packet that may cause CPU overload.
*
Use this row to make the setting the same for all entries. Use this row first and then make
adjustments to each entry if necessary.
Note: Changes in this row are copied to all the entries as soon as you make them.
Active
Select this option to have the Switch detect if the configured rate limit for a specific control
packet is exceeded and take the action selected below.
Mode
Select the action that the Switch takes when the number of control packets exceed the rate
limit on a port, set in the
Advanced Application > Errdisable > CPU protection
screen.
•
inactive-port
- The Switch disables the port on which the control packets are received.
•
inactive-reason
- The Switch drops all the specified control packets on the port.
•
rate-limitation
- The Switch drops the additional control packets the port has to handle
in every one second.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Cancel
Click
Cancel
to begin configuring this screen afresh.
Содержание MES3500 Series
Страница 16: ...Table of Contents MES3500 Series User s Guide 16 Appendix C Legal Information 357 Index 362...
Страница 17: ...17 PART I User s Guide...
Страница 72: ...72 PART II Technical Reference...
Страница 106: ...Chapter 9 VLAN MES3500 Series User s Guide 106 Figure 49 Advanced Application VLAN Port Based VLAN Setup Port Isolation...
Страница 178: ...Chapter 22 Policy Rule MES3500 Series User s Guide 178 Figure 98 Policy Example EXAMPLE...
Страница 360: ...Appendix C Legal Information MES3500 Series User s Guide 360 Environmental Product Declaration...