Chapter 9 VLAN
MES3500 Series User’s Guide
107
The following table describes the labels in this screen.
Table 25
Advanced Application > VLAN: Port Based VLAN Setup
LABEL
DESCRIPTION
Setting
Wizard
Choose
All connected
or
Port isolation
.
All connected
means all ports can communicate with each other, that is, there are no virtual
LANs. All incoming and outgoing ports are selected. This option is the most flexible but also the
least secure.
Port isolation
means that each port can only communicate with the CPU management port and
cannot communicate with each other. All incoming ports are selected while only the CPU
outgoing port is selected. This option is the most limiting but also the most secure.
After you make your selection, click
Apply
(top right of screen) to display the screens as
mentioned above. You can still customize these settings by adding/deleting incoming or outgoing
ports, but you must also click
Apply
at the bottom of the screen.
Incoming
These are the ingress ports; an ingress port is an incoming port, that is, a port through which a
data packet enters. If you wish to allow two subscriber ports to talk to each other, you must
define the ingress port for both ports. The numbers in the top row denote the incoming port for
the corresponding port listed on the left (its outgoing port).
CPU
refers to the Switch
management port. By default it forms a VLAN with all Ethernet ports. If it does not form a VLAN
with a particular port then the Switch cannot be managed from that port.
Outgoing
These are the egress ports. An egress port is an outgoing port, that is, a port through which a
data packet leaves. If you wish to allow two subscriber ports to talk to each other, you must
define the egress port for both ports.
CPU
refers to the Switch management port. By default it
forms a VLAN with all Ethernet ports. If it does not form a VLAN with a particular port then the
Switch cannot be managed from that port.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Cancel
Click
Cancel
to begin configuring this screen afresh.
Содержание MES3500 Series
Страница 16: ...Table of Contents MES3500 Series User s Guide 16 Appendix C Legal Information 357 Index 362...
Страница 17: ...17 PART I User s Guide...
Страница 72: ...72 PART II Technical Reference...
Страница 106: ...Chapter 9 VLAN MES3500 Series User s Guide 106 Figure 49 Advanced Application VLAN Port Based VLAN Setup Port Isolation...
Страница 178: ...Chapter 22 Policy Rule MES3500 Series User s Guide 178 Figure 98 Policy Example EXAMPLE...
Страница 360: ...Appendix C Legal Information MES3500 Series User s Guide 360 Environmental Product Declaration...