Chapter 8 Basic Setting
MES-3528 User’s Guide
86
The following table describes the labels in this screen.
Table 12
Basic Setting > Port Setup
LABEL
DESCRIPTION
Port
This is the port index number.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports.
Use this row first to set the common settings and then make adjustments
on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you
make them.
Active
Select this check box to enable a port. The factory default for all ports is
enabled. A port must be enabled for data transmission to occur.
Name
Enter a descriptive name that identifies this port. You can enter up to 64
alpha-numerical characters.
Note: Due to space limitation, the port name may be truncated in
some web configurator screens.
Type
This field displays 10/100M for Fast Ethernet connections and 10/100/
1000M for Gigabit connections.
Speed/
Duplex
Select the speed and the duplex mode of the Ethernet connection on this
port. Choices are Auto, 10M/Half Duplex, 10M/Full Duplex, 100M/
Half Duplex, 100M/Full Duplex and 1000M/Full Duplex (Gigabit
connections only).
Selecting Auto (auto-negotiation) allows one port to negotiate with a peer
port automatically to obtain the connection speed and duplex mode that
both ends support. When auto-negotiation is turned on, a port on the
Switch negotiates with the peer automatically to determine the connection
speed and duplex mode. If the peer port does not support auto-negotiation
or turns off this feature, the Switch determines the connection speed by
detecting the signal on the cable and using half duplex mode. When the
Switch’s auto-negotiation is turned off, a port uses the pre-configured
speed and duplex mode when making a connection, thus requiring you to
make sure that the settings of the peer port are the same in order to
connect.
Flow Control
A concentration of traffic on a port decreases port bandwidth and overflows
buffer memory causing packet discards and frame losses. Flow Control is
used to regulate transmission of signals to match the bandwidth of the
receiving port.
The Switch uses IEEE802.3x flow control in full duplex mode and
backpressure flow control in half duplex mode.
IEEE802.3x flow control is used in full duplex mode to send a pause signal
to the sending port, causing it to temporarily stop sending signals when
the receiving port memory buffers fill.
Back Pressure flow control is typically used in half duplex mode to send a
"collision" signal to the sending port (mimicking a state of packet collision)
causing the sending port to temporarily stop sending signals and resend
later. Select Flow Control to enable it.
Содержание MES-3528 -
Страница 2: ......
Страница 8: ...Safety Warnings MES 3528 User s Guide 8 ...
Страница 22: ...22 ...
Страница 32: ...Chapter 2 Hardware Installation and Connection MES 3528 User s Guide 32 ...
Страница 42: ...Chapter 3 Hardware Overview MES 3528 User s Guide 42 ...
Страница 44: ...44 ...
Страница 60: ...Chapter 5 Initial Setup Example MES 3528 User s Guide 60 ...
Страница 76: ...Chapter 7 System Status and Port Statistics MES 3528 User s Guide 76 ...
Страница 88: ...Chapter 8 Basic Setting MES 3528 User s Guide 88 ...
Страница 90: ...90 ...
Страница 109: ...Chapter 9 VLAN MES 3528 User s Guide 109 Figure 57 Port Based VLAN Setup Port Isolation ...
Страница 114: ...Chapter 10 Static MAC Forward Setup MES 3528 User s Guide 114 ...
Страница 146: ...Chapter 14 Bandwidth Control MES 3528 User s Guide 146 ...
Страница 160: ...Chapter 17 Link Aggregation MES 3528 User s Guide 160 ...
Страница 168: ...Chapter 19 Port Security MES 3528 User s Guide 168 ...
Страница 180: ...Chapter 21 Policy Rule MES 3528 User s Guide 180 ...
Страница 192: ...Chapter 23 VLAN Stacking MES 3528 User s Guide 192 ...
Страница 231: ...Chapter 26 IP Source Guard MES 3528 User s Guide 231 Figure 120 DHCP Snooping ...
Страница 248: ...Chapter 26 IP Source Guard MES 3528 User s Guide 248 ...
Страница 257: ...257 PART IV IP Application Static Route 259 Differentiated Services 263 DHCP 267 ...
Страница 258: ...258 ...
Страница 262: ...Chapter 29 Static Route MES 3528 User s Guide 262 ...
Страница 274: ...Chapter 31 DHCP MES 3528 User s Guide 274 ...
Страница 276: ...276 ...
Страница 284: ...Chapter 32 Maintenance MES 3528 User s Guide 284 ...
Страница 306: ...Chapter 33 Access Control MES 3528 User s Guide 306 ...
Страница 312: ...Chapter 35 Syslog MES 3528 User s Guide 312 ...
Страница 320: ...Chapter 36 Cluster Management MES 3528 User s Guide 320 ...
Страница 324: ...Chapter 37 MAC Table MES 3528 User s Guide 324 ...
Страница 329: ...329 PART VI Troubleshooting Product Specifications Troubleshooting 331 Product Specifications 335 ...
Страница 330: ...330 ...
Страница 342: ...Chapter 41 Product Specifications MES 3528 User s Guide 342 ...
Страница 343: ...343 PART VII Appendices and Index Changing a Fuse 345 Common Services 347 Legal Information 351 Index 355 ...
Страница 344: ...344 ...
Страница 346: ...Appendix A Changing a Fuse MES 3528 User s Guide 346 ...
Страница 354: ...Appendix C Legal Information MES 3528 User s Guide 354 ...
Страница 364: ...Index MES 3528 User s Guide 364 ...