Chapter 17 Link Aggregation
GS1915 Series User’s Guide
157
17.4 Technical Reference
This section provides technical background information on the topics discussed in this chapter.
17.4.1 Static Trunking Example
This example shows you how to create a static port trunk group for ports 2
–
5.
1
Make your physical connections
– make sure that the ports that you want to belong to the trunk group
are connected to the same destination. The following figure shows ports 2
–
5 on switch
A
connected to
switch
B
.
Figure 112
Trunking Example
–
Physical Connections
System Priority
LACP system priority is a number between 1 and 65535. The switch with the lowest system priority
(and lowest port number if system priority is the same) becomes the LACP “server”. The LACP
“server” controls the operation of LACP setup. Enter a number to set the priority of an active port
using Link Aggregation Control Protocol (LACP). The smaller the number, the higher the priority
level.
Group ID
The field identifies the link aggregation group, that is, one logical link containing multiple ports.
LACP Active
Select this option to enable LACP for a trunk.
Port
This field displays the port number.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first to set
the common settings and then make adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you make them.
LACP Timeout
Timeout is the time interval between the individual port exchanges of LACP packets in order to
check that the peer port in the trunk group is still up. If a port does not respond after three tries,
then it is deemed to be “down” and is removed from the trunk. Set a short timeout (1 second) for
busy trunked links to ensure that disabled ports are removed from the trunk group as soon as
possible.
Select either 1 second or 30 seconds.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Cancel
Click
Cancel
to begin configuring this screen afresh.
Table 72 Advanced Application > Link Aggregation > Link Aggregation Setting > LACP (continued)
LABEL
DESCRIPTION
Содержание GS1915 Series
Страница 17: ...17 PART I User s Guide ...
Страница 39: ...39 PART II Technical Reference ...
Страница 101: ...Chapter 8 Basic Setting GS1915 Series User s Guide 101 Figure 75 Basic Setting PoE Setup PoE Setup ...
Страница 209: ...GS1915 Series User s Guide 209 Figure 146 Advanced Application LLDP LLDP Local Status LLDP Local Port Status Detail ...
Страница 280: ...GS1915 Series User s Guide 280 Figure 206 Example Lock Denoting a Secure Connection EXAMPLE ...
Страница 309: ...309 PART III Troubleshooting and Appendices ...