Chapter 29 Access Control
ES-2024 Series User’s Guide
211
29.3.1 SNMP v3 and Security
SNMP v3 enhances security for SNMP management. SNMP managers can be required to
authenticate with agents before conducting SNMP management sessions.
Security can be further enhanced by encrypting the SNMP messages sent from the managers.
Encryption protects the contents of the SNMP messages. When the contents of the SNMP
messages are encrypted, only the intended recipients can read them.
29.3.2 Supported MIBs
MIBs let administrators collect statistics and monitor status and performance.
The Switch supports the following MIBs:
• SNMP MIB II (RFC 1213)
• RFC 1157 SNMP v1
• RFC 1493 Bridge MIBs
• RFC 1643 Ethernet MIBs
• RFC 1155 SMI
• RFC 2674 SNMPv2, SNMPv2c
• RFC 1757 RMON
• SNMPv2, SNMPv2c or later version, compliant with RFC 2011 SNMPv2 MIB for IP,
RFC 2012 SNMPv2 MIB for TCP, RFC 2013 SNMPv2 MIB for UDP
29.3.3 SNMP Traps
The Switch sends traps to an SNMP manager when an event occurs. The following tables
outline the SNMP traps by category.
An OID (Object ID) that begins with “
1.3.6.1.4.1.890.1.5.8.16
” (ES-2024A) or
“
1.3.6.1.4.1.890.1.5.8.27
” (ES-2024PWR) is defined in private MIBs. Otherwise, it is a
standard MIB OID.
Table 79
SNMP System Traps
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
coldstart
coldStart
1.3.6.1.6.3.1.1.5.1
This trap is sent when the Switch is
turned on.
warmstart
warmStart
1.3.6.1.6.3.1.1.5.2
This trap is sent when the Switch
restarts.
fanspeed
FanSpeedEventOn
1.3.6.1.4.1.890.1.5.8.16.27.2.1 This trap is sent when the fan speed
goes above or below the normal
operating range.
FanSpeedEventClear
1.3.6.1.4.1.890.1.5.8.27.27.2.2 This trap is sent when the fan speed
returns to the normal operating
range.
temperature TemperatureEventOn
1.3.6.1.4.1.890.1.5.8.16.27.2.1 This trap is sent when the
temperature goes above or below
the normal operating range.
TemperatureEventClear
1.3.6.1.4.1.890.1.5.8.27.27.2.2 This trap is sent when the
temperature returns to the normal
operating range.
Содержание ES-2024 Series
Страница 2: ......
Страница 7: ...Safety Warnings ES 2024 Series User s Guide 7 This product is recyclable Dispose of it properly...
Страница 8: ...Safety Warnings ES 2024 Series User s Guide 8...
Страница 20: ...Table of Contents ES 2024 Series User s Guide 20...
Страница 28: ...List of Tables ES 2024 Series User s Guide 28...
Страница 30: ...30...
Страница 38: ...Chapter 2 Hardware Installation and Connection ES 2024 Series User s Guide 38...
Страница 44: ...Chapter 3 Hardware Overview ES 2024 Series User s Guide 44...
Страница 46: ...46...
Страница 56: ...Chapter 4 The Web Configurator ES 2024 Series User s Guide 56...
Страница 66: ...Chapter 6 Tutorials ES 2024 Series User s Guide 66...
Страница 86: ...86...
Страница 98: ...Chapter 9 VLAN ES 2024 Series User s Guide 98...
Страница 104: ...Chapter 11 Static Multicast Forwarding ES 2024 Series User s Guide 104...
Страница 136: ...Chapter 18 Port Authentication ES 2024 Series User s Guide 136...
Страница 170: ...Chapter 22 AAA ES 2024 Series User s Guide 170...
Страница 185: ...185 PART IV IP Application Static Route 187 Differentiated Services 191 DHCP 195...
Страница 186: ...186...
Страница 190: ...Chapter 25 Static Route ES 2024 Series User s Guide 190...
Страница 202: ...202...
Страница 226: ...Chapter 29 Access Control ES 2024 Series User s Guide 226...
Страница 228: ...Chapter 30 Diagnostic ES 2024 Series User s Guide 228...
Страница 232: ...Chapter 31 Syslog ES 2024 Series User s Guide 232...
Страница 242: ...Chapter 33 MAC Table ES 2024 Series User s Guide 242...
Страница 248: ...248...
Страница 256: ...Appendix A Product Specifications ES 2024 Series User s Guide 256...
Страница 268: ...Appendix C Legal Information ES 2024 Series User s Guide 268...
Страница 282: ...Index ES 2024 Series User s Guide 282...