AAM1212 User’s Guide
Chapter 22 Diagnostic
159
22.2.1 Log Messages
The following table lists and describes the system log messages.
Table 54
Log Messages
LOG MESSAGE
TYPE
DESCRIPTION
ADSL <port> Link
Up(SN=<seq no>):
<ds rate>/<us
rate>!
or
ADSL Link Info:
NM:<ds NM>/<us
NM>!
INFO
An ADSL port established a connection.
<port>
- port number
<seq no>
- sequence number of the connection
<ds rate>
- downstream rate
<us rate>
- upstream rate
<us NM>
- upstream noise margin
<ds NM>
- downstream noise margin
ADSL <port> Link
Down(SN=<seq no>)!
WARN
An ADSL port lost its connection.
<port>
- port number
<seq no>
- sequence number of the connection
Session Begin!
INFO
A console, telnet or FTP session has begun (see the
<process> field for the type of session).
Session End!
INFO
A console telnet or FTP session has terminated (see the
<process> field for the type of session).
Incorrect
Password!
WARN
Someone attempted to use the wrong password to start a
console, telnet or FTP session (see the <process> field for the
type of session).
Received Firmware
Checksum Error!
WARN
A checksum error was detected during an attempted FTP
firmware upload.
Received Firmware
Size too large!
WARN
The file size was too large with an attempted FTP firmware
upload.
Received Firmware
Invalid!
WARN
Someone attempted to upload a firmware file with a wrong
identity via FTP.
Received File
<file>!
INFO
A file was uploaded to the AAM by FTP.
<file>
- received file’s name.
THERMO OVER
TEMPERATURE:
dev:<id>
threshold:<thresho
ld>(degree C)
value:<temp>(degre
e C)!
WARN
The temperature was too high at one of the temperature
sensors.
<id>
- 0: sensor near the ADSL chipset
- 1: sensor near the CPU
- 2: thermal sensor chip itself
<threshold>
- threshold temperature
<temp>
- temperature when the entry was logged
THERMO OVER
TEMPERATURE
released: dev:<id>
threshold:<thresho
ld>(degree C)
value:<temp>(degre
e C)!
INFO
The temperature at one of the temperature sensors has come
back to normal.
<id>
- 0: sensor near the ADSL chipset
- 1: sensor near the CPU
- 2: thermal sensor chip itself
<threshold>
- threshold temperature
<temp>
- temperature when the entry was logged
Содержание AAM1212
Страница 1: ...AAM1212 ADSL2 Module over POTS in the IP DSLAM User s Guide Version 3 50 9 2005 ...
Страница 23: ...AAM1212 User s Guide 22 ...
Страница 27: ...AAM1212 User s Guide 26 ...
Страница 35: ...AAM1212 User s Guide 34 Chapter 1 Getting to Know Your AAM1212 ...
Страница 49: ...AAM1212 User s Guide 48 Chapter 3 Hardware Connections ...
Страница 55: ...AAM1212 User s Guide 54 Chapter 4 Web Configurator Introduction ...
Страница 63: ...AAM1212 User s Guide 62 Chapter 5 Initial Configuration ...
Страница 71: ...AAM1212 User s Guide 70 Chapter 6 Home and Port Statistics Screens ...
Страница 83: ...AAM1212 User s Guide 82 Chapter 7 Basic Setting Screens ...
Страница 111: ...AAM1212 User s Guide 110 Chapter 8 ADSL Port Setup ...
Страница 143: ...AAM1212 User s Guide 142 Chapter 18 Syslog ...
Страница 151: ...AAM1212 User s Guide 150 Chapter 19 Access Control ...
Страница 163: ...AAM1212 User s Guide 162 Chapter 22 Diagnostic ...
Страница 181: ...AAM1212 User s Guide 180 Chapter 25 Commands Overview ...
Страница 249: ...AAM1212 User s Guide 248 Chapter 29 IP Commands ...
Страница 261: ...AAM1212 User s Guide 260 Chapter 30 Statistics Commands ...
Страница 277: ...AAM1212 User s Guide 276 Chapter 33 Troubleshooting ...
Страница 283: ...AAM1212 User s Guide 282 Virtual Circuit Topology ...