1.

 

Application  

 

Zuzi microscopes P Series have been designed and developed to be used in different fields of 

applications as biology, bacteriology, histology or pathology. The can also be used in education 

and University research.  

2.

 

Description  

 

The different parts of the microscope are shown on below image (Figure 1) 

 

Figure 1.

 Trinocular model T-HC16 

Depending on the model the head can be binocular (Modelo B-HC15) o trinocular (Modelo T-

HC16).  The  Siedentopf  head  is  30º  inclined  and  360º  rotatable  with  a  lateral  screw  to  fix  its 

position. The interpupillary distance can be easily adjusted (55-75mm) and they have diopter 

correction in both eyepieces (Figure 2).  

The  trinocular  model  T-HC16  is  provided  with  a  height  adjustable  third  tube  in  which  a  USB 

videocamera can be placed. 

Содержание B-HC15

Страница 1: ...o Le recomendamos leer atentamente el presente manual y seguir rigurosamente los procedimientos de uso para obtener las m ximas prestaciones y una mayor duraci n del mismo This manual should be availa...

Страница 2: ...Uso del equipo 7 5 Mantenimiento 9 6 Causas de una mala imagen 9 7 Resoluci n de problemas 9 8 Recomendaciones pr cticas 10 9 Accesorios incluidos 11 English 12 1 Application 13 2 Description 13 3 Tec...

Страница 3: ...ientos Si esto ocurre desenchufe inmediatamente el equipo de la toma de corriente Cualquier duda puede ser aclarada por su distribuidor instalaci n puesta en marcha funcionamiento Nunca desmonte el eq...

Страница 4: ...a siguiente imagen Figura 1 Figura 1 Modelo triocular T HC16 Dependiendo del modelo el cabezal del microscopio puede ser binocular Modelo B HC15 o triocular Modelo T HC16 El cabezal tipo Siedentopf es...

Страница 5: ...pulaci n de las preparaciones sea m s c moda La platina es mec nica de doble lecho con mando de traslaci n coaxial y dispone de una pinza para dos preparaciones el microscopio dispone de tornillo para...

Страница 6: ...B HC15 T HC16 CABEZAL Binocular Triocular Tipo Siedentopf inclinado 30 y giratorio 360 Distancia interpupilar regulable 55 75mm ajuste de dioptr as en ambos oculares OCULARES WF10x 18 mm REV LVER Cu d...

Страница 7: ...para ver qu resultados obtiene y si funciona correctamente e Inserte el enchufe en la parte trasera del equipo Inserte el otro extremo en la toma de corriente el ctrica Si las bater as est n cargadas...

Страница 8: ...para subir la platina hasta que la preparaci n quede a unos pocos mil metros del objetivo A continuaci n gire suavemente el microm trico hasta conseguir una imagen enfocada g Una vez la imagen est bi...

Страница 9: ...ec nicas limpias y secas g Desenchufe el cable de alimentaci n y desconecte el microscopio si no va a ser utilizado ajuste la intensidad de iluminaci n al m nimo y cubra el microscopio con la funda pr...

Страница 10: ...llo gire el rev lver ligeramente a ambos lados hasta que este encaje correctamente Si existe polvo o suciedad visible en el campo de visi n Compruebe la existencia de polvo en la lente del precondensa...

Страница 11: ...a pel cula de aceite ya que se deteriora en gran medida la imagen resultante c Se recomienda secar la lente frontal despu s de cada observaci n Nunca debe usarse gamuza Debe hacerse con un papel espec...

Страница 12: ...In case it may happen unplug the equipment immediately If you have any doubt installation setting up operation please contact your distributor Never dismantle the different pieces of the microscope to...

Страница 13: ...icroscope are shown on below image Figure 1 Figure 1 Trinocular model T HC16 Depending on the model the head can be binocular Modelo B HC15 o trinocular Modelo T HC16 The Siedentopf head is 30 incline...

Страница 14: ...e comfortable The stage is a double layer mechanical stage with translation coaxial knob and presents a double clamp to hold up to two slides The microscope is provided with a safety screw to fix the...

Страница 15: ...HBC015 HBC016 MODEL B HC15 T HC16 HEAD Binocular Trinocular Siedentopf type inclined 30 and rotary 360 Interpupillary distance adjustment 55 75mm diopter correction in both eyepieces EYEPIECES WF10x...

Страница 16: ...plug into the socket at the back of the microscope Connect the other end to the electrical power supply If the batteries are charged the microscope can be used without connecting to the electrical pow...

Страница 17: ...change to the next higher magnification objective and adjust focus by turning only fine focusing knob To change the objective turn the nosepiece until hearing a click sound and make sure it is well c...

Страница 18: ...cover the microscope with the dust cover h To replace the fuse open the fuse holder with a flat screwdriver Remove the fuse and replace it 6 Causes of a defective image In case of a defective image yo...

Страница 19: ...er or the eyepiece as well as the cleanliness of the sample Once you find out where the dirt is you should clean it as explained before If the sample gets fuzzy while observing Check the tension adjus...

Страница 20: ...st focusing with the fine knob d We highly recommend drying the frontal lens after each use You should never use a duster Instead of it you should use specific optics cloth and liquids that are sold t...

Отзывы: