15
Method C: Local PC RS-232 Control (Console)
RS232 Protocol/ASCII Commands
Serial COM Port Settings
Connect a 9-pin straight through RS-232 cable from the MAHCL4X4 to your Home or Commercial
Automation System. Configure the serial communications port on your automation system or PC to these
settings.
Baud Rate: 9600 bps
Data Bit: 8 bits
Parity: None
Stop Bit: 1 bit
Flow Control: None
**Note** All Commands Require a Carriage Return <CR>
POWER Standby/ON
PWR 00<CR>
Puts matrix in Standby
PWR 01<CR>
Turns matrix On
Example Response:
PONOK
(Matrix is in Standby)
POFFOK
(Matrix is On)
SINGLE OUTPUT CHANGE
TX* ?<CR>
*=Output(* can be 1 to 4) ?=Input(? can be 01 to 04, 00=Off)
Example Commands:
TX1 03<CR>
Output1 to Input3
(Response back from matrix will be
OK1 03
or
NG
)
TX3 02<CR>
Output3 to
Input2(Response back from matrix will be
OK3 02
or
NG
)
TX2 01<CR>
Output2 to Input1
(Response back from matrix will be
OK2 01
or
NG
)
TX4 00<CR>
Output4 Off(Response back from matrix will be
OK4 00
or
NG
)
Remote HDBaseT RS-232 Control:
* Extender (HE1LBIR232) connection, please refer to the connection diagram page.
* Transmission baud rate up to 115200 bps.
* Two-way transmission