ZURN Z6140 Скачать руководство пользователя страница 1

Aquaflush

Flush V

alves

Aquaflush

®

Z6100 Series

Aquaflush Concealed Flushometer

Installation, Operation, 
Maintenance, and Parts Manual

Patented and Patents Pending

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of 
purchase. Decorative finishes warranted for one year. We will replace at no cost goods that prove defective provided we are notified in writing of such
defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in accordance with
instructions. We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, including incidental or consequential 
damages. The sole and exclusive remedy shall be limited to the replacement of the defective goods. Before installation and use, the purchaser shall
determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith. Where
permitted by law, the implied warranty of merchantability is expressly excluded. If the products sold hereunder are “consumer products,” the implied
warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods. All weights 
stated in our catalogs and lists are approximate and are not guaranteed.

Aquaflush Concealed
Closet/Urinal Systems
Z6140
Z6142
Z6143
Z6144
Z6150
Z6152
Z6154
Z6155
Z6190
Z6195
Z6196

Z6140

Z6195

FV251 Page 1

Содержание Z6140

Страница 1: ...ges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the i...

Страница 2: ...ection Z6152 1 1 2 Water Closet valve with back spud connection Z6190 1 1 4 Urinal Valve with top spud connection Z6195 3 4 Urinal Valve with top spud connection FLOWS WS1 Low Consumption 1 0 Gal for Urinal 1 6 Gal for Water Closet WS Water Saver 1 5 Gal for Urinal 3 5 Gal for Water Closet Standard Flow FF Full Flow 3 0 Gal for Urinal 4 5 Gal for Water Closet OPTIONS BG BioCare ADA Handle J Metal ...

Страница 3: ...consumption valves 1 6 gallon require a minimum of 25 psi running pressure through the valve to obtain proper evacuation When installing your quality Zurn valve it is recommended that a smooth jawed wrench be used This will prevent gouges and scratches on your valve Before starting the installation process bore a 1 1 2 hole in wall for actuator and a 2 hole for piping if required 4 Insert the adju...

Страница 4: ...t largest size Step 3 Order the applicable suffix shown at the intersection of the row and column Example For closet valve model number Z6152 and a wall thickness of 6 order Z6152 LDIM9 Combination Closets Urinals Fixtures 6140 6152 6602 6142 6154 6602 Wall 6143 6155 6609 6601 Thickness 6144 6605 6190 6613 6603 W 6150 6611 6681 6195 6615 6616 1 4 LDIM4 LDIM7 LDIM4 LDIM5 1 LDIM4 LDIM7 LDIM4 LDIM5 2...

Страница 5: ...00 D SD Seal Seat for 1 and 3 4 Includes Item 33 P6000 D42 Sweat Solder Connection P6000 YBA Adjustable Tailpieces Product No Adjustable Tailpiece for Standard Flush Valve Includes Items 28 31 P6000 J1 RB Tailpiece Locking Ring Includes Item 29 P6000 C30 Tailpiece O Ring Includes Item 30 P6000 C31 Coupling Nut Includes Item 31 P6000 C32 RB Flush Connections and Spud Coupling Kits Product No Flush ...

Страница 6: ...12 flush valves Valve is flushing too long or 1 Trip mechanism not seating properly due to foreign 1 Disassemble parts and rinse thoroughly not shutting off material between trip mechanism and retainer disc 2 By pass orifice is plugged or partially plugged 2 Examine by pass orifice and clean if necessary being certain not to enlarge orifice opening 3 Line pressure is not adequate to force 3 Pressu...