GENERAL INFORMATION

Zurn solids interceptors are specifically designed to capture and retain solid particles for a variety of different drain line applications. Units are
available in Dura-Coated cast iron, bronze, Acid Resistant Coated steel and stainless steel, along with a multitude of screens designed for each
application. If you require a solids interceptor not listed, phone (814-455-0921) or fax (814-871-6141) your requirements to the Zurn Engineering
Department for assistance. Special screens and sizes are available to meet almost any need.

Recommended Size

Fixture

Solid Interceptor

Compartment

Drainage

One-minute

Two-minute

Size

Number of

Load

Drainage

Drainage

(Inches)

Compartments

(Gallons)

Period

Period

18 x 12 x 6

1

4.2

7

4

16 x 14 x 8

1

5.8

7

4

20 x 18 x 8

1

9.4

10

7

18 x 16 x 8

2

15.0

15

10

20 x 18 x 8

2

18.7

20

10

30 x 20 x 8

1

15.5

20

10

24 x 20 x 12

1

18.7

20

10

22 x 20 x 8

2

23.0

25

15

22 x 20 x 12

2

34.0

35

20

24 x 24 x 12

2

44.9

50

25

Product selection should be made with a specific application and the type of construction in mind. The varied types and sizes of Zurn
interceptors, along with their options, offer a selection for all applications.

APPLICATION INDEX

APPLICATION

RECOMMENDED INTERCEPTOR

Food Preparation

Z1181, Z1182, Z1183, Z1183-DF

Hair Salons

Z1175, Z1176, Z1180, Z1184

Plaster

Z1180, Z1181

Barium

Z1180

Fish Scales

Z1181, Z1183

Garbage Disposal

Z1181, Z1182, Z1183, Z1183-DF

With Z1170 and Z1173 Interceptors

Z1181, Z1182, Z1183, Z1183-DF

Selection Chart

SIZING

All Zurn solids interceptors are designed for gravity flow where 
minimal head is expected. Zurn solids interceptors are designed 
to accommodate the flow rate of their inlet and outlet pipe size,
provided they are maintained and kept clean.

Zurn solids interceptors should be sized by both expected flow rate
and holding capacity. Sizing for the Z1181 solids interceptor should
be sized by the number and size of the sinks being served as is the
case with the Z1170 grease interceptor.

Содержание Z1175

Страница 1: ... 15 0 15 10 20 x 18 x 8 2 18 7 20 10 30 x 20 x 8 1 15 5 20 10 24 x 20 x 12 1 18 7 20 10 22 x 20 x 8 2 23 0 25 15 22 x 20 x 12 2 34 0 35 20 24 x 24 x 12 2 44 9 50 25 Product selection should be made with a specific application and the type of construction in mind The varied types and sizes of Zurn interceptors along with their options offer a selection for all applications APPLICATION INDEX APPLICA...

Страница 2: ... 16502 PHONE 814 455 0921 FAX 814 454 7929 WEBSITE www zurn com Page 50 PICTORIAL INDEX SOLIDS INTERCEPTORS Z1182 Side Access Solids Interceptor Z1183 Solids Interceptor Z1181 Solids Interceptor Z1180 Solids Interceptor Z1184 Bottom Access Solids Interceptor Z1183 DF Solids Interceptor with Disposable Filter Bags ...

Страница 3: ...eptor options and variations are specified as a PREFIX and or SUFFIX letter or number added to the series designation Below are the available options PREFIXES Z Standard Assembly See Engineering Specification ZA Acid Resistant Coated Fabricated Steel or Dura Coated Cast Iron ZAB All Satin Finish ZS All Type 304 Fabricated Stainless Steel SUFFIXES AR Acid Resistant Coated Fabricated Steel Finish CP...

Страница 4: ...iciency of operation is directly related to the level of maintenance Z1181 SOLIDS INTERCEPTOR OPERATION and MAINTENANCE INSTRUCTIONS SIZING There are no sizing requirements for this interceptor except to specify the inlet and outlet size All units are made with a standard 2 51 mm pipe size inlet and outlet reduced to 1 1 2 38 mm with a bushing when specified and are capable of handling drainage vo...

Страница 5: ...lean Apply a light coating of oil on the gasket Z1183 SOLIDS INTERCEPTOR OPERATION and MAINTENANCE INSTRUCTIONS SIZING The sizing of this interceptor relates to the size of the Z1170 grease interceptor it is being used with All units are made with a standard no hub pipe size inlet and outlet and are capable of handling drainage volumes standard to their respective pipe size DESIGN The Zurn Z1183 S...

Страница 6: ...erature water will not occur to the acid resistant composite material of this unit when installed downstream from a dishwasher There is a chance however that the thin walled PVC screen in the bucket may deform It is recommended that a stainless steel perforated screen be used in applications that involve high temperature water Z1183 DF SOLIDS INTERCEPTOR with DISPOSABLE FILTER BAGS OPERATION and M...

Страница 7: ...ic Hydrocarbons E E Chlorinated Hydrocarbons F F Ketones F F Ethers F F Esters F F Gasoline E E Carbon Tetrachloride E E Organics Aniline G P Benzenc E E Formaldehyde 37 E G Phenol 5 G F Mineral Oils E E Vegetable Oils E E Chlorobenzene G P Z1180 and Z1184 CHEMICAL RESISTANCE CHART For Composite Material in Light Acid Concentration Environment Only Key E Excellent Corrosion Resistance G Good F Fai...

Страница 8: ...te a a Potassium sulfate a a Silver nitrate a a Salts Continued Silver cyanide a a Sodium bicarbonate a a Sodium borate a a Sodium bromide a a Sodium chloride 2 aerated a a Sodium citrate a a Sodium fluoride b Sodium hydroxide a a Sodium nitrate a a Sodium peroxide 212 F a a Stannic chloride c c Stannous chloride b Sulfur molten 500 F a a Sulfur chloride b Titanium tetrachloride a a Zinc chloride ...

Страница 9: ...t is ideally suited to traffic bearing grates and strainers in finished floor areas It affords the combined advantage of greater strength better appearance and longer service life at the same price as chrome plated brass Superior ductility and shock resistance are the result of a copper nickel alloy Copper Alloy 997 having a wearing surface similar in appearance to satin chrome plate however becau...

Отзывы: