background image

MAINTENANCE

1. YOUR ZURN AQUASPEC FAUCET HAS A HIGHLY POLISHED NICKEL CHROME PLATED FINISH.  CLEAN WITH SOAP  AND 

WATER OR A MILD CLEANER WHICH IS SAFE FOR CHROME PLATING.  DO NOT USE ACIDS OR TOILET BOWL CLEANER 
AS THEY WILL DAMAGE THE FINISH.

2.  METERING CARTRIDGE (#3) REMOVAL AND REPLACEMENT

2.1. REMOVE COLORED INDEX BUTTON (#1D) FROM HANDLES (#1A + #1B)

2.2. LOOSEN SET SCREWS (#1C) IN HANDLE WITH 3/32” ALLEN WRENCH

2.3. PULL UP ON HANDLE TO REMOVE FROM STEM (#2C) OF HANDLE NUT ASSEMBLY (#2)

2.4. REMOVE HANDLE NUT ASSEMBLY (#2) USING 1-1/8” HEX 6-POINT SOCKET

2.5. REMOVE METERING CARTRIDGE (#3) BY LIFTING OUT OF FAUCET BODY (#4). IT MAY BE NECESSARY TO OPEN 

THE SUPPLY STOP SLIGHTLY TO ALLOW WATER PRESSURE TO PUSH THE METERING CARTRIDGE UPWARD.

2.6

INSPECT METERING CARTRIDGE (#3) FOR WORN PARTS, DAMAGED PARTS AND ANY CONTAMINATION THAT 
MAY BE PREVENTING THE METERING CARTRIDGE FROM MOVING FREELY OR SEATING. OTHER THAN 
CLEANING ANY TRAPPED DEBRIS, THERE ARE NO SERVICEABLE PARTS IN THE METERING CARTRIDGE. 
CONTAMINATED OR DAMAGED METERING CARTRIDGE ASSEMBLIES SHOULD BE REPLACED.

2.7

REVERSE STEPS 2.1 THROUGH 2.5 FOR RE-ASSEMBLY.  TIGHTEN CAP (#2G) WITH 1-1/8” HEX 6-POINT SOCKET 
UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE FAUCET IS RUNNING. 
HOLD DOWN HANDLES (#1A + #1B) WHILE TIGHTENING SET SCREW (#1C) TO ENSURE PROPER SEATING

3.

IT MAY BE NECESSARY TO REPLACE OR BACK FLUSH THE INTEGRAL SHANK FILTER  AND AERATOR  PERIODICALLY 
TO REMOVE COLLECTED SEDIMENT AND DEBRIS

3.1.  INTEGRAL SHANK FILTER(#4) IS REMOVED USING A 1/4” ALLEN WRENCH.

REPLACEMENT PARTS

HANDLE NUT ASSEMBLY 

G60561 

METERING CARTRIDGE ASSEMBLY 

G61754

HANDLE ASSEMBLY 

G61830

INTEGRAL SHANK FILTER 

G67787

AIR DELIGHTS, INC.

9974 SWARCTIC DR 
BEAVERTON,  OR  97005 
PHONE:  1-800-440-5556  FAX: 1-503-643-8442
www.airdelights.com

ADJUSTING THE FLOW ON ZURN METERING FAUCET

1. METERING FAUCETS ARE FACTORY PRESET FOR A 10 SEC. CYCLE AT 80 PSI.

2. ACTUATE FAUCET 3 TO 5 TIMES TO REMOVE ANY TRAPPED AIR IN THE SUPPLY LINE OR FAUCET

3. REMOVE HANDLE (#1) PER INSTRUCTIONS IN MAINTENANCE SECTION 2.1 THROUGH 2.3 TO EXPOSE ADJUSTMENT 

NUT (#2F)

4. INCREASE CYCLE TIME BY TIGHTENING ADJUSTMENT NUT (#2F) 1/2 TURN CLOCKWISE. DECREASE CYCLE TIME BY 

LOOSENING ADJUSTMENT NUT 1/2 TURN COUNTERCLOCKWISE. CHECK FOR DESIRED CYCLE TIME BY ACTUATING 
FAUCET WITH HANDLE (#1) IN PLACE ON STEM (#2C)

PAGE 2 OF 4

 Installation Instructions are revised frequently.
 Please access website for the latest revision.

*

Form #

 CF102 

Date:

 4/2/07

C.N. No.

 106044 

Rev.

 M

Содержание AQUASPEC Z86500 Series

Страница 1: ... 7 TURN SUPPLY WATER ON AND OPERATE THE FAUCET WHILE CHECKING FOR LEAKS 8 INSTALL SPRAY OUTLET 6 INTO FAUCETAND HAND TIGHTEN 9 METERING CARTRIDGE IS FACTORY PRESET FOR A 10 SECOND CYCLE AT 80 PSI IF ADJUSTMENT IS NECESSARY SEE ADJUSTING THE FLOW SECTION PAGE 2 PAGE 1 OF 4 Form CF102 Date 4 2 07 C N No 106044 Rev M IMPORTANTTHE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PR...

Страница 2: ... 8 HEX 6 POINT SOCKET UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE FAUCET IS RUNNING HOLD DOWN HANDLES 1A 1B WHILE TIGHTENING SET SCREW 1C TO ENSURE PROPER SEATING 3 IT MAY BE NECESSARY TO REPLACE OR BACK FLUSH THE INTEGRAL SHANK FILTER AND AERATOR PERIODICALLY TO REMOVE COLLECTED SEDIMENT AND DEBRIS 3 1 INTEGRAL SHANK FILTER 4 IS REMOVED USING A 1 4 ALLEN WRENCH REPLACEME...

Страница 3: ...3 Stem 1 2C 60450001 Spring Seat 1 2D 60447001 Spring 1 2E 60446001 Adjustment Nut 1 Item Part Number Description Qty 2F 60452001 Cap 1 2G 60456001 Stem Housing 1 2H 62499107 O Ring 1 2I 60458001 O Ring Retainer 1 3 G61754 Metering Cartridge Ass y 2 3A 81121001 O Ring 1 3B 81241001 Washer 1 4 G67787 Integral Shank Filter 2 5 92109001 4 102mm Centerset Body 1 6 G63561 13 16 27 Male Spray Outlet 0 2...

Страница 4: ...s adjustment Aerator is not installed or incorrect aerator installed Metering cartridge is overly contaminated or damaged Faucet will not shut off Faucet is making noise at shutoff Handles becoming loose with normal usage Install 1 0 GPM or 0 5 GPM aerator Facuet may not shut off with aerator s 1 0 GPM Tighten handle nut using 1 1 8 hex 6 point socket to create seal and seat metering cartridge Do ...

Отзывы: