background image

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the 

date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are 

notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly 

maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages 

whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the 

defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the 

purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability 

is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a 

period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists 

are approximate and are not guaranteed.

Sensor-Operated Lavatory Faucets with Smart Connected Features

NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.

     Z6920-XL-W1

     Z6922-XL-W1

AquaSense

®

Connected EZ Gear Hardwire 

Powered Sensor Faucets

Installation, Operation, Maintenance

and Parts Manual

Patented and Patents Pending

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

Содержание AquaSense Z6920-XL-W1

Страница 1: ... the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective good...

Страница 2: ...d Tools AquaSense Package Contents Adjustable Wrench Optional Smooth Jawed Wrench Phillips Head Screwdriver 3 32 M3 Allen Wrenches Filter Endpoint Y Cable CWB DC Adapter NOTE The information in this manual is subject to change at any time without notice Installations may be performed at different times of construction by different individuals For this reason these instructions should be left on si...

Страница 3: ...1 a Install endpoint on wall surface within 2 feet radius of faucet with dry wall anchors screws or doubled sided VHB tape 1 b For concealed wiring installation drill 3 16 hole in wall surface for DC power cable route wire end through hole to HW6 unit After routing apply sealant around wire in hole Endpoint Electronic Module Installation Instructions 4 Connect Y cable to electronics module assembl...

Страница 4: ...ation for the Zurn Gateway Select a location central to all devices to be connected to this gateway Place the gateway as high as possible such as near the top of a wall Avoid obstructions Thick walls and reflective surfaces such as metal weaken the signal between the gateway and other devices The LoRa antenna is an omni directional antenna but for best results mount the device so the LoRa antenna ...

Страница 5: ... 663 9876 for assistance with additional troubleshooting steps and if needed unit replacement Trouble Shooting LoRa Monitor For further assistance with troubleshooting visit https plumbsmart zurn com app training Problem Possible Cause Corrective Action Faucet is non responsive Battery voltage low or no power Verify power is provided by ACA Sensor and electronic connector cable has bent or broken ...

Страница 6: ...hooting Gateway For further assistance with troubleshooting visit https plumbsmart zurn com app training Problem Corrective Action Usage data presented in Water Usage Chart does not match expected usage Step 1 Confirm installed aerator model s gallons minute specification matches parameter setting in plumbSMART product page Parameters tab If factory original aerator is installed reset parameter va...

Страница 7: ... body you must first turn water off then remove spout Spout Replacement P6900 120BC Filter in standard faucet installation Control Box Attach adapter here with MV P6900 12BC Filter P6900 MV ADAP Supplied Adapter with MV Option To Control Box Supplied Adapter 3 8 Copper Tube By Others For use with MV Option Mixing Valve Filter and Mixing Valve Installation ...

Страница 8: ...922 No Lead Spout Base with Sensor Assembly Item 3B P6922 XL 2 Z6920 Mounting Kit Item 4A P6920 43 Z6922 Mounting Kit Item 4B P6920 43 Smart Connected Faucet Retrofit Kit Items 5 8 P6900 RK W1 Description Product No Filter Kit Item 9 P6900 120BC Filter Screen Item 10 P6900 MV 7 Mixing Valve with Filter Item 11 P6900 XL MV Composite Mixing Valve Adapter Item 12 P6900 MV ADAP Ceramic Valve Item 13 P...

Страница 9: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev E Date 07 02 21 C N No 143882 Prod Dwg No FV743 ...

Отзывы: