Thanks for choosing ZDAS-16CA-8 Multi-Function Alarm Control Panel. We suggest you 

reading carefully this guide, operating this system strictly on the standard procedure. 

ZDAS-16CA-8

 is suitable for most circumstances and convenient for using, no matter its 

appearance, function, or operation. We hope this Guide could answer most of your questions 

when using the system.   

 

Chapter 1 Summarize 

1.1 Summarize 

ZDAS-16CA-8

  takes  advanced  microprocessor  as  its  core  technology.  So  it  has  the 

advantages of high integration, very good stability, flexible function and convenient use. 

1.2 Attentions before usage 

 

Get approval from local police office before presetting the police phone number as 

the alarm phone number 

 

Ensure the system is in the correct installation, then connect AC power supply with 

the panel   

 

Only suitable for DC 12V 7AH sealed lead rechargeable storage battery, be cautious 

to connect red positive line with positive terminal 

+

, and black negative line with 

negative terminal

(-)

. The incorrect connection will cause damage of main panel. 

 

Rechargeable current 

 1.5A 

 

Avoid metal parts or hand contact to the electronic parts on the circuit when install 

the lines. 

 

Must use 2.7K resistor short unused wired zone 

 

Mark wires to avoid miss-connection when using too many wired zones   

 

Cut off all AC power supply, battery and telephone line before maintenance 

 

Short JP1 when reset main panel 

 

The 1.00MM copper-core wire from the keypad to alarm panel is up to 150 meters, 4 

keypads can be connected in series 

1.3 Features 

 

High speed digital communication, compatible 2, CID digital 
communication protocol

Send alarm signal to alarm center. 

 

Different programmable settings, such as alarm sounds, zone types, recording, 
monitoring, remote controlling, telephone number, phone line Check, and etc. 

 

Compatible with wired and wireless function   

 

1 group 6 bits primary passwords, 15 groups subsidiary setting passwords are 
available to improve security; 

Содержание ZDAS-16CA-8

Страница 1: ...hargeable storage battery be cautious to connect red positive line with positive terminal and black negative line with negative terminal The incorrect connection will cause damage of main panel Rechar...

Страница 2: ...on Operate from keypad easily and convenient Phone line malfunction indication function system will alarm when phone line is cut off or short The alarm dialling is in priority Backup DC 12V 7AH sealed...

Страница 3: ...ge 3of 16 Chapter 2 Installation and Connection 2 1 Wiring Diagram 2 1 1 Wiring diagram on main board Indicator LED will light on when working normally Z1 Z8 means 1 8 zone 2 1 2 Wiring diagram of exp...

Страница 4: ...ry the black wire should be connected to negative of battery 2 3 Connection of Wired Detector 2 3 1 Connection of signal wires of wired detector There are two connection way to avoid destroy cutoff or...

Страница 5: ...m panel The wire from the keypad to alarm panel is up to 150 meters 4 keypads can be connected in series to avoid destroy of keypad the anti temper port could be connected to the terminal of alarm pan...

Страница 6: ...it will dial the preset numbers in turn You can take the following action See 3 7 3 1 4 Zone LED will keep light on in alarm status till someone comes When you go to office or home use remote control...

Страница 7: ...t on ARM Status Emergency Key A B C 24 hours Alarm Status can be defined as Fire Alarm Robbery Alarm Emergency Call No indicator no sound If telephone preset it will dial the number when alarm the com...

Страница 8: ...Operation User Password 6 bits F4 Confirm Key Factory User Password 123456 or press key on Remote Controller 2 Disarm Succeed ARM Indicate Light off if the system refuse the dictate the Buzzer will sh...

Страница 9: ...12 seconds or press 8 exit recording press 6 play the finished recorded sound then hang up If need new record sound press 8 exit then press 7 stat new record sound till it s satisfied 3 Confirm Record...

Страница 10: ...nd a long Di the indicator LED will light off Or exit automatically after 30 seconds the buzzer will not sound indicator LED off 4 5 Change Installer Password 1 Start Set Mode see 4 3 2 Format 30 New...

Страница 11: ...irstly 4 8 Delete Wireless Detectors 1 Start Set Mode see4 3 2 Delete a remote controller or a wireless detector 21 zone number 2 bits F4 Confirm Key 3 Repeat Step 2 to delete more remote controllers...

Страница 12: ...F4 Confirm Key Delete 3rd group telephone number 53 F4 Confirm Key Set 4th group telephone number 54 Telephone F4 Confirm Key Delete 4th group telephone number 54 F4 Confirm Key Set 5th group telepho...

Страница 13: ...2 Code See 4 20 2 ADEMOCO 4 2 code 3 Exit Set Mode see4 4 4 18 Remote Control On Off 1 Start Set Mode see4 3 2 Format 71 status F4 Confirm Key Status 0 Remote Control Off 1 Remote Control On Factory S...

Страница 14: ...time 1 Start Set Mode see4 3 2 Press 42 time 2 bits F4 confirm key Time 00 40 Alarm time 00 40 x 30 second Factory setting 02 means 02 x 30 60seconds 4 26 Set Boundary Arm 1 Start Set Mode see4 3 2 F...

Страница 15: ...tory Setting 0 3 Exit Set Mode see4 4 4 34 Set Center Precision 1 Start Set Mode see4 3 2 Press 65 precision value 1 bit F4 value 0 9 Factory Setting 6 3 Exit Set Mode see4 4 4 35 Set Center Signal Ti...

Отзывы: