7.3.6.
Software Update
The HYD 10-20KTL-3PH inverters offer the possibility to update the system via a USB stick for
maximising the inverter's performance and preventing any operating errors caused by software bugs.
Procedure:
1.
Insert the USB stick into the inverter (the files necessary for the update are already inside it)
2.
Open the DC switch
3.
6.Software Update
OK
Enter password
OK
Enter 0715
Start Update
Updating DSP1…
Updating DSP2…
Updating ARM…
4.
If any of the errors listed below appear, repeat the operation. If this happens several times,
contact the support service.
USB Fault
MDSP File Error
SDSP File Error
ARM File Error
Update DSP1 Fail
Update DSP2 Fail
Update ARM Fail
Table 18 - Software update errors
5.
After completing the update, close the DC switch, wait for the LCD screen to turn off; then
restore the WiFi connection and open both the DC and AC switches, wait a few seconds for the
inverter to turn on again. To check the current version of the system update, go to System Info
> Software Version.