Hardware Development Guide of Module Product
38
All Rights reserved, No Spreading abroad without Permission of ZTEWelink
6.2
Description of Testing Environment
The working temperature range of ZM5202 is divided into the normal working
temperature range and the extreme working temperature range. Under the normal
working temperature range, the testing result of RF complies with the requirements
of 3GPP specifications, and its function is normal. Under the extreme temperature
range, the RF index basically complies with the 3GPP specifications, and the quality
of data communication is affected to a certain extent, but its normal function is not
affected. ZM5202 has passed the EMC test. Table 6-2 is the requirement for the
testing environment, and Table 6-3 lists out the instruments and devices that might
be used during the test.
Table 6-2 Testing Environment
Working
Condition
Min
Temperature
Max
Temperature
Remark
Normal
working
condition
-20
°
C
75
°
C
All the
indexes are
good.
Extreme
working
condition
-40
°
C
85
°
C
Some
indexes
become
poorer.
Storage
-40
°
C
85
°
C
Storage
environment
of ZM5202
Table 6-3 Testing Instrument & Device
Testing Item
Instrument & Device
RF test
Comprehensive
testing device
RF cable
Tower antenna
Microwave darkroom
High/Low-temperature
running & storage test
High/Low-temperature
experimental box
Temperature shock
test
Temperature shock
experimental box
Vibration test
Vibration console