Chapter 2 Alarm
l
If no, replace the board.
4.
If the alarm persists after the preceding steps, the unit (for receiving signals) in the
RUT board of NR8250 is faulty. Replace the board.
2.1.11 134237778 Loopback state in TDM port
Alarm Property
l
Alarm Code: 134237778
l
Alarm Information: TDMA loopback. The alarm is reproted when the port on the
RTUA/RTUB/RTUC/RTUH board is in loopback (inner/outer) status.
l
Alarm Level: Critical
l
Alarm Type: Equipment Alarm
Sub-code Description
l
134283264. E1-1 port (LMT displays “E1-1”);
l
134348800. E1-2 port (LMT displays “E1-2”);
l
134414336. E1-3 port (LMT displays “E1-3”);
l
134479872. E1-4 port (LMT displays “E1-4”);
l
134545408. E1-5 port (LMT displays “E1-5”);
l
134610944. E1-6 port (LMT displays “E1-6”);
l
134676480. E1-7 port (LMT displays “E1-7”);
l
134742016. E1-8 port (LMT displays “E1-8”);
l
134807552. E1-9 port (LMT displays “E1-9”);
l
134873088. E1-10 port (LMT displays “E1-10”);
l
134938624. E1-11 port (LMT displays “E1-11”);
l
135004160. E1-12 port (LMT displays “E1-12”);
l
135069696. E1-13 port (LMT displays “E1-13”);
l
135135232. E1-14 port (LMT displays “E1-14”);
l
135200768. E1-15 port (LMT displays “E1-15”);
l
135266304. E1-16 port (LMT displays “E1-16”).
l
135331840. E1-16 port (LMT displays “E1-17”)
l
135397376. E1-16 port (LMT displays “E1-18”)
l
135462912. E1-16 port (LMT displays “E1-19”)
l
135528448. E1-16 port (LMT displays “E1-20”)
l
135593984. E1-16 port (LMT displays “E1-21”)
l
135659520. E1-16 port (LMT displays “E1-22”)
l
135725056. E1-16 port (LMT displays “E1-23”)
l
135790592. E1-16 port (LMT displays “E1-24”)
l
135856128. E1-16 port (LMT displays “E1-25”)
l
135921664. E1-16 port (LMT displays “E1-26”)
l
135987200. E1-16 port (LMT displays “E1-27”)
l
136052736. E1-16 port (LMT displays “E1-28”)
l
136118272. E1-16 port (LMT displays “E1-29”)
2-9
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential