ZXMW NR8250 Alarm and Notification Handling Reference
Possible Causes
It is the notification of the standby-to-active changeover being completed.
Handling Procedure
None
3.5 10006 Board power-on failure
Notification Property
l
Notification Code: 10006
l
Notification Information: The notification is reported when the board fails to be
powered on due to the board's basic process power-on failure or timeout.
l
Notification Type: Equipment Alarm
Sub-code Description
l
Sub-code 1: Process power-on failure
l
Sub-code 2: Process power-on timeout
Effect on the System
The board fails to operate normally.
Possible Causes
The process fails to be powered on or timeout.
Handling Procedure
Check whether module timeout occurs. If yes, change the software version.
3.6 10012 Module reset
Notification Property
l
Notification Code: 10012
l
Notification Information: The module is reset.
l
Notification Type: Equipment Alarm
Sub-code Description
None
Effect on the System
The module is reset.