SPECIFICATIONS
MULTIRELAY
ZEN16 VER. 2.0
www.getzooz.com
[email protected]
USER MANUAL
FEATURES
Ÿ
Powerful dry contact relays to control loads up to 15 A and 20 A
Ÿ
Perfect for outdoor lighting, pool pumps, garage door, or gas fireplace
Ÿ
Control up to 3 connected loads independently or together
Ÿ
Z-Wave or optional wall switch control (toggle or momentary type)
Ÿ
VER. 2.0:
700 series Z-Wave chip and SmartStart S2 security
Ÿ
Built-in timers for each relay to simplify automation
Ÿ
Remembers and restores on/off status a er power failure
Ÿ
Built-in
Z-Wave Plus signal repeater to extend network range
Ÿ
Powered by 12-24 V DC/AC or USB C port for easy set-up
Ÿ
Wall mounting and minimal design for clean installation
Ÿ
Model Number: Z
EN16
Ÿ
Z-Wave Signal Frequency: 908.42 MHz
Ÿ
Power: 12-24 V DC/AC or USB C (DON’T use laptop / tablet
chargers)
Ÿ
Maximum Load:
Relay 1: 15A
( HP)
, R2: 15A
( HP)
, R3: 20
A (
HP)
Ÿ
Range: Up to 100 feet line of sight
Ÿ
Operating Temperature: 32-104° F (0-40° C)
Ÿ
Installation and Use: Indoor only
CAUTION
This is an electrical device - please use caution when installing and
operating the MultiRelay. Remote control of appliances may result in
unintentional or automated activation of power.
WIRING: READ IT!
This
device
is intended for installation in accordance with
the National Electric Code and local regulations. It is
recommended that a licensed electrician perform this
installation. USE A SINGLE POWER SOURCE AT ALL TIMES.
BEFORE YOU
INSTALL
1. CHECK THE LOAD:
make sure that the connected appliance does not
exceed 15 A for Relay 1 and Relay 2 or 20 A for Relay 3.
2. POWER OFF:
turn the circuit power off in the breaker panel before
you start. If handling wiring from a box with multiple circuits, turn
power off at all of the circuits.
3. REMOVE THE WALL SWITCH:
if the load is currently controlled by a
wall switch, carefully remove it from the box and disconnect the wires
from the switch.
4. CONNECT THE MULTIRELAY:
follow
the instructions in the
appropriate diagram for your set-up
.
If you can’t find your scenario in
the diagrams below, please request custom instructions from our
support team, we’re happy to help:
WIRING TIPS
µ
Before you disconnect any wires, document your set-up and send us
images of your existing installation so we can help if needed.
@
Always use the correct screwdriver size for the terminal screws on your
MultiRelay and wall switches (if connecting them). Use appropriate ele-
ctrical tools when cutting, prepping, and stripping electrical wires. If you
don’t have the necessary tools to perform the installation or are not
sure which tools to use or how, please hire an electrician to complete
the installation for you.
~
Follow the National Electrical Code and your local safety regulations
when performing the installation, including (but not limited to), choo-
sing the correct gauge of jumper wires. The recommended gauge for 15
Amp circuits is 14 AWG and 12 AWG for 20 Amp circuits.
FIRMWARE VERSION 2.10
PAGE 2
PAGE 1
TAKE PICTURES
GATHER YOUR TOOLS
SAFETY FIRST
HOW TO SECURE WIRES IN TERMINALS:
first, unscrew the appropriate
terminal’s screw just far enough so there is a clear opening in the termi-
nal for the wire to go in. Make sure the wire is stripped at the right length
and perfectly straight before you insert it into the terminal. Once you
put the wire in the terminal, carefully screw the terminal screw back in
to hold down the wire. Check the connection by gently pulling on the
connected wire to make sure it’s fixed securely.
5. POWER THE MULTIRELAY:
connect the USB C power source to the
MultiRelay
or
use the
“+” “-” terminals on the device to bring low voltage
power to it
.
Never use both at the same time.
In both cases you’ll
need a standard 1 A power adapter to plug into a standard 120 VAC
receptacle.
Do NOT use with laptop or tablet chargers
, they require a
large battery on load to activate.
ZOOZ MULTIRELAY ZEN16 WIRING DIAGRAMS
ZEN16 WIRING DIAGRAM FOR GARAGE DOOR OPENERS
R1
R1
R2
R2
-R3-
Sw1
Sw2
Sw3
+
-
WALL
SWITCH
USB C
12-24 V (DC/AC) POWER INPUT
TH
TP
TP
TH
+
+
+
POWER ADAPTER
GAS FIREPLACE MILLIVOLT VALVE
Connect to
simple wall
momentary
opener
switches only! “Fancy”
switches with electronic
displays will not work
with the MultiRelay.
Use with
traditional
motorized
garage door openers only. The
MultiRelay will NOT work with
smart openers like the myQ
system.
R1
R1
R2
R2
-R3-
Sw1
Sw2
Sw3
+
-
BELL WIRE
OPENER 1
OPENER 2
OPENER 3
SWITCH 1 SWITCH 2 SWITCH 3
POWER ADAPTER
USB C
12-24 V (DC/AC) POWER INPUT
ZEN16 WIRING DIAGRAM FOR GAS FIREPLACE MILLIVOLT VALVE
ZEN16 WIRING DIAGRAM FOR POOL LIGHT AND POOL PUMP
POOL
PUMP
R1
R1
R2
R2
-R3-
Sw1
Sw2
Sw3
+
-
LIGHT
SWITCH
USB C
12-24 V (DC/AC) POWER INPUT
POWER ADAPTER
POOL
LIGHT
POWER SOURCE
PUMP
SWITCH
Scan with your phone’s
camera and click on the
link to program the ZEN16
on your hub.