Model MDPA2 Ver.04
Installation and Operating Instructions
Controlling Your Comfort Room By Room
Страница 1: ...Digi Zone Adder Model MDPA2 Ver 04 Installation and Operating Instructions Controlling Your Comfort Room By Room ...
Страница 2: ...ed with MDPA2 in order to place remotely The MDPA2 panel case is made of sturdy ABS plastic and can be mounted to any flat surface It is recommended that the panel be mounted to a wall or return plenum and NOT on the furnace or plenum where it will be in contact with the hot temperatures The panel can be located in an attic space or in an enclosed cabinet of a rooftop unit Insure the panel is not ...
Страница 3: ...or has a two color LED that a positive indication of the damper being open or closed When the LED is GREEN the damper is Open When the LED is RED the damper is closed ZONE DAMPER ZONE DAMPER WIRING DIAGRAM 1 Conventional Thermostat Y G C R W OB E ZONE THERMOSTAT TERMINALS C W R Y G ZONE THERMOSTAT WIRING DIAGRAM 2 Heat Pump Thermostat Y G C R W OB E ZONE THERMOSTAT TERMINALS C O B R Y G E ZONE THE...
Страница 4: ...LED is Green the motor LED must be Green also indicating the damper being open When the panel LED is not lit the damper should be closed and this is confirmed by the damper LED being Red Power LED Not On If the Power LED is not Illuminated GREEN and there is 24VAC at the transformer terminals the MDPA has a built in thermal fuse light brown rectangle component below transformer terminals that may ...