PREPARING THE RS-4000 OUTPUT 2
The RS-4000 energizes the orange output wire with 12 vdc for .5 to 1 second when a configured threshold has
been exceeded. The ZOLL Road Safety Diagnostics viewer is used to configure the RS-4000 device to send this
output for each of the violations detected by the device.
CONFIGURING THE RS-4000 DIGITAL OUTPUT 2 TO SEND TRIGGERS
1.
Run the diagnostic viewer on the RS-4000 using one of these two methods:
a.
Direct Connection – This method requires a direct connection of a monitor, mouse and keyboard
to the RS-4000. Details on this method can be found on
b.
Wirelessly – This method can be used if both the RS-4000 and a desktop/laptop computer are on
the same network subnet. The computer being used must have the Diagnostics Viewer software
installed. Details on this method can be found on
2.
Press the “Play” button on the far left to connect to the RS-4000
3.
Click the third button from the left (Edit Hardware
Configuration by VID).
4.
The “Edit Value” dialog box
displays. Here the second option
button should be selected.
5.
Enter the value of the VID you
wish to update. In our example
397 has been entered. This is the
VID for a high RPM.
6.
In the value field, 000500 has
been entered which will send a
half second 12VDC pulse through
the RS-4000 Digital OUTPUT 2.