12 VOLT DC BATTERY BACKUP PUMP

PREINSTALLATION CHECKLIST

®

© Copyright 2016 Zoeller

®

 Co. All rights reserved.

1.  Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer before using.
2.  Read all the installation instructions regarding installing and start up. Retain for future reference.

SEE BELOW FOR 

LIST OF WARNINGS

1.  Testing for Ground. As a safety measure each electrical outlet should 

be checked for ground using an Underwriters Laboratory listed circuit 

analyzer, which will indicate if the power, neutral and ground wires are 

correctly connected to your outlet. If they are not, call a qualified, licensed 

electrician.

2.  For your protection always disconnect the power supply from its power 

source before handling the components of your DC backup pump or the 

primary pump.

3.  Installation and checking of electrical circuits and hardware should be 

performed by a qualified, licensed electrician. 

4.  All electrical and safety codes must be followed in addition to the National 

Electrical Code and all applicable local codes. 

5.  

It is the owner’s responsibility to check the battery and battery 

connection at least once a month. Batteries contain acid and 

caution must be taken when handling.

6.  Risk of electric shock - These pumps have not been investigated for use 

in swimming pool areas.

7.  According to the state of California (Prop 65), this product contains 

chemicals known to the state of California to cause cancer and birth 

defects or other reproductive harm.

1.  Make sure there is a properly grounded 115V receptacle available. Do 

not use primary pump circuit. The location must be within 6' of the control 

box and battery. The power supply for your DC control system plugs 

directly into the 115V outlet. DO NOT USE AN EXTENSION CORD.

2.  Make sure the 115V electrical supply circuit is equipped with fuses or 

circuit breakers of proper capacity.

3.  DC emergency pumps are designed for handling clear water. Do not use 

in septic tanks to pump effluent or sewage pits to pump sewage.

4.  Repair and service of your DC backup system should be performed by 

an authorized service station.

5.  The installation of DC automatic backup pumps requires the use of a 

variable level float switch for operation. It is the responsibility of the 

installing party, to ensure that the float switch will not hang up on the 

pump apparatus or pit peculiarities and is secured so the pump will turn 

“on” and “off”. It is recommended that the pit be 18" in diameter or larger 

to accommodate both a primary and a DC backup pump.

6.  For indoor use only.

CAUTION

SEE BELOW FOR 

LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

CAUTION

  Turbulence caused by high velocity incoming 

water can cause sump pumps to airlock. If this condition exists, 

the incoming water must be baffled to avoid excessive turbulence.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:

  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:

  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

®

Your Peace of Mind is Our Top Priority

 

®

®

ANY

 CHANGES MADE 

TO 

THIS DOCUMENT

 ALSO MA

Y

 AFFECT

 

FM131

1f & FM131

1s, HF1312, FM1

139 & FW0477 FOR F&W

.

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

Содержание Basement Sentry Series

Страница 1: ...ther reproductive harm 1 Make sure there is a properly grounded 115V receptacle available Do not use primary pump circuit The location must be within 6 of the control box and battery The power supply...

Страница 2: ...wered and the float drops to the off position 2 Plug the control charger and the primary pump into the wall outlet a The primary pump will come on and lower the water to the normal operating level and...

Страница 3: ...DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure The DC pump electronic controls and all the parts required for installation...

Страница 4: ...vent weld that piece first to the tee Measure cut solvent weld any remaining discharge piping above the tee Finally connect the discharge pipe to the in line check valve and tighten hose clamp See Fig...

Страница 5: ...TH SUBMERSIBLE PUMP BATTERY BOX TM R TM R BATTERY BOX OUTLET PRIMARY PUMP DC PUMP PLUMBED IN LINE WITH COLUMN PUMP IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP 1 MIN SK2499...

Страница 6: ...PPLIED BY USER FIG 5 DC BACK UP PUMP CLAMP FLOAT SWITCH WHITE LEAD TO POSITIVE BLACK LEAD TO DC PUMP WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE 15 AMP FUSE DC CHARGER BLACK LEAD TO NEGATIVE TO FLOA...

Страница 7: ...current going to the battery if charging The alarm screen shows current alarms The cycle counter screen shows how many times the DC float has been activated The AC power loss counter screen shows how...

Страница 8: ...recommendations as to what can be done to prevent the alarm activation MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP F...

Отзывы: