background image

ATTENTION: READ CAREFULLY BEFORE ATTEMPTING TO INSTALL OR OPERATE YOUR PUMP. PROTECT YOURSELF AND OTHERS 

BY OBSERVING ALL SAFETY INFORMATION AND ADDITIONAL INSTRUCTIONS INCLUDED WITH EQUIPMENT. FAILURE TO COMPLY 

WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN FOR FUTURE REFERENCE.

SECTION: 6.10.143

FM2340

0711

Supersedes

0110

INSTALLATION INSTRUCTIONS

These installation instructions are applicable for Model 370-0002 Aeration/Fountain Pump only.

This pump system is designed for decorative use and can improve water aeration.

PREINSTALLATION  CHECKLIST  -  ALL  INSTALLATIONS

AERATION/FOUNTAIN PUMP MODEL 370-0002

SEE BELOW FOR LIST OF WARNINGS

1

Make certain that the power source conforms to the requirements of 

the equipment as stated on the product nameplates and wire motor for 

correct voltage.  See motor nameplate.

2.

  Periodically inspect the pump for damage and perform routine 

maintenance as required.

3.

  The maximum temperature of the pumped liquid must not exceed 120

°

F. 

4.

  Supply voltage must be with in +/- 10% of nameplate voltage.  Incorrect 

voltage can cause fire or seriously damage motor and voids warranty.  If 

in doubt, consult a licensed electrician.

 

REFER TO WARRANTY ON PAGE 2.

SEE BELOW FOR LIST OF CAUTIONS

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

®

Your Peace of Mind is Our Top Priority

 

®

 1.   Make sure that the pump is plugged into a properly grounded 

electrical receptacle.

 Use an Underwriters Laboratory listed circuit 

analyzer to test for proper installation of the circuit and ground. Any service 

to circuits or receptacles should be conducted by a qualified licensed 

electrician.

 2.   

Do not remove the ground pin from the plug under any circumstances.

 

If the ground pin is damaged, replace the power cord or plug before use.

 3.   

All electrical installations must conform to the requirements of the National 

Electric Code and all local codes.

 4.

  System furnished with a 100 ft. power cord with 3-prong GFCI plug; must 

connect to properly grounded receptacle of grounding type.  Do not 

remove ground pin on plug.  Do not extend the cord length by splicing 

or with an extension cord.

 5.   

Disconnect power before servicing the pump or motor by unplugging 

the unit from the outlet.

  6.   

 

  

Do not touch the motor when operating and allow the motor 

to cool before touching.

 7.

   Pump is built to handle clear water only; it is not designed to handle water 

containing sand, silt, or other abrasives.

   8. 

Do not use to pump flammable or explosive fluids such as  

gasoline, kerosene, fuel oil, etc.  Do not use in flammable 

and/or explosive atmospheres.

9.   

 

  

 

Do not use this product in hazardous environments or 

anywhere a spark could potentially ignite explosive gases.

 10.   

Do not handle this product with wet hands or while standing in water 

or on a wet or damp surface.

 11.

 Units are supplied with an automatically resetting thermal overload 

device and can restart without warning.

 

12. 

 

Provide a means of pressure relief if the pump discharge 

can be shut off or obstructed.  Pumps operating against a 

closed discharge can create very hot pumped liquid, which 

can cause burns.

 

13.

  “No swimming” and/or warning signs should be posted per state and 

local codes.  Please affix included warning label to power receptacle 

or junction box.

14. 

 Do not ground to a gas supply line.

 15. 

Protect the power cable from coming in contact with sharp objects, oil, 

grease, hot surfaces, or chemicals.  DO NOT kink the power cable.  If 

damaged, replace immediately.

  16.     

According to the state of California (Prop 65), this product contains 

chemicals known to the state of California to cause cancer and birth 

defects or other reproductive harm.

 17. 

NEVER leave the control box, fused disconnect switch or cover open 

(either partially or completely) when not being worked on by a competent 

electrician.

 18. 

Water leaving nozzle is at a high velocity and can cause bodily injury 

if contact is made.

 19. 

Never examine, make wiring changes, or touch the motor before 

disconnecting the main electrical supply switch.  The thermal device 

may have opened the electrical circuit.  All motors should be equipped 

with a correctly fused disconnect switch to provide protection. Consult 

local or United States National Electrical Codes for proper fuse protection 

based on motor data chart.

 20. 

GFI plug must be oriented with cord coming out of the bottom and 

protected from direct rainfall.

021766

Содержание 370-0002

Страница 1: ...3 prong GFCI plug must connect to properly grounded receptacle of grounding type Do not remove ground pin on plug Do not extend the cord length by splicing or with an extension cord 5 Disconnect power before servicing the pump or motor by unplugging the unit from the outlet 6 Do not touch the motor when operating and allow the motor to cool before touching 7 Pump is built to handle clear water onl...

Страница 2: ...ERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY Somestatesdonotallowlimitationsonthedurationofanimpliedwarranty so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have...

Страница 3: ...upply in accordance with the National Electrical Code and all applicable local codes and ordinances 8 After installing the unit checking ground and connecting power to the unit the unit can be powered up Check operation of the GFCI by pushing the Test button the unit should stop Pushing the Reset button should restart the unit If pressing the Test button does not stop the unit immediately shut off...

Страница 4: ...8 Stainless Steel 2A 1 021617 Nozzle Water Lily 2B 1 021618 Nozzle Sky Cannon 2C 1 021619 Nozzle Water Trumpet 3 1 021622 O Ring AS568A 041 3 ID x 3 18 OD 4 6 021628 Bolt SS 1 4 20 x 3 4 5 6 021629 Lockwasher 1 4 6 1 021707 Mounting Flange 7 1 021534 Float 8 1 021713 Pump End 9 1 021740 Motor 1 2 HP 115V 10 4 127021 Locknut SS 5 16 24 11 1 021715 100 ft power cord with GFI 12 2 021609 Eye Bolt SS ...

Отзывы: