1
FIGURE 1
MODEL NO.
SUMP
SEWAGE
10-4659
X
10-4660
X
53-0084
X
98-0069
X
267-0121
X
SWITCH TYPE
POWER WIRE COLOR
SUMP
RED
SEWAGE
BLUE
DISCHARGE PIPE
CORDS SECURED TO
LEVEL
PUMP "OFF"
LEVEL
PUMP "ON"
ZOELLER UNICHECK
TO POWER SUPPLY
REDUNDANT "ON"
LEVEL
MOUNT FLOATLESS SWITCH
WITH (2) TIE STRAPS THAT
ARE PROVIDED WITH SWITCH.
PUMP PLUG
SWITCH PLUG
AUTOMATIC
OPERATION
MANUAL
OPERATION
L1
L2
SWITCH
DISCONNECT
WATERTIGHT
JUNCTION BOX
WHITE
BLACK
SEE CHART
BLACK
WHITE
WHITE
GREEN
BLACK
PUMP
FLOATLESS
SWITCH
SK3180
READ ALL INSTRUCTIONS BEFORE INSTALLING - ALL APPLICATIONS
Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of proper capacity. A separate
branch circuit is recommended, sized according to the National Electrical Code for the current shown on the pump name plate.
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING
.
Single phase pumps are supplied with a 3-prong grounded plug to help protect you against the possibility of electrical shock.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN
.
The 3-prong plug must be inserted into
a mating 3-prong grounded receptacle. If the installation does not have such a receptacle, it must be changed to the proper type,
wired and grounded in accordance with the National Electrical Code and all applicable local codes and ordinances.
NOTICE TO INSTALLER: Instructions must remain with installation.
SECTION: 2.50.240
FM3087
1018
Supersedes
New
CAUTION
Zoeller 10-4659 and 10-4660 water level Floatless switches are designed for use with the appropriate voltage and horsepower,
nonautomatic, single phase Zoeller pumps.
CAUTION
Maximum temperature must not exceed 122 °F (50 °C). NOTE: cULus code approval. NOTE: Consult factory for controlling
units over 1/2 HP with variable level float switch.
ZOELLER FLOATLESS WATER LEVEL SWITCH
10-4659, 10-4660 - 115 V / UP TO 1/2 HP - 15' (5 M) CORD
DESIGNED FOR EFFLUENT, SEWAGE AND DEWATERING APPLICATIONS
© Copyright 2018 Zoeller
®
Co. All rights reserved.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
MAIL TO
: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO
: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL
: (502) 778-2731 • 1 (800) 928-PUMP •
FAX
: (502) 774-3624
Visit our web site:
zoellerpumps.com
INSTALLATION INSTRUCTIONS
1. Loop provided tie strap through switch as shown in Figure 1 and 3, leaving approximately 3" of slack for ease of installation.
2. Lower switch into pit.
3. Place the bottom of the switch against the discharge pipe.
OFF
level should be approximately 4" above the inlet of the pump. The
ON
level must be below the check valve, the inlet and lid of the pit.
4. Be certain the outward face of the switch has 2" minimum clearance from any foreign objects, including the wall of the pit, the
discharge pipe, and the pump.
5. Securely fasten top and bottom of the switch to the discharge pipe by tightening the two tie straps.
6. Insert the piggyback plug from the switch into a standard grounded outlet of proper voltage.
For installation using watertight junction box, reference Figure 4.
7. Securely tape or clamp both switch and pump cord to the discharge pipe, clear of switch range (refer to step 4).
8. Plug sump pump into the switch's piggyback plug. See Figure 2.
9. Clean basin free of debris after installation.
10. Check and test your installation. Fill basin with water and allow pump to cycle to ensure proper range and operation.
Note: The Floatless control switch needs a minimum of 2" clearance between all foreign objects in the basin / pit. The switch has a
maximum run time of 2 minutes. Ensure your basin is appropriate before installing the Floatless switch.
FIGURE 2
MODEL NO.
SUMP
SEWAGE
10-4659
X
10-4660
X
53-0084
X
98-0069
X
267-0121
X
SWITCH TYPE
POWER WIRE COLOR
SUMP
RED
SEWAGE
BLUE
DISCHARGE PIPE
CORDS SECURED TO
LEVEL
PUMP "OFF"
LEVEL
PUMP "ON"
ZOELLER UNICHECK
TO POWER SUPPLY
REDUNDANT "ON"
LEVEL
MOUNT FLOATLESS SWITCH
WITH (2) TIE STRAPS THAT
ARE PROVIDED WITH SWITCH.
PUMP PLUG
SWITCH PLUG
AUTOMATIC
OPERATION
MANUAL
OPERATION
L1
L2
SWITCH
DISCONNECT
WATERTIGHT
JUNCTION BOX
WHITE
BLACK
SEE CHART
BLACK
WHITE
WHITE
GREEN
BLACK
PUMP
FLOATLESS
SWITCH
PART NO.
SUMP
SEWAGE
MODEL
NO.
VOLTAGE
PHASE
10-4659
X
10-4660
X
53-0084
X
LN53
115V
1
98-0069
X
LN98
115V
1
267-0121
X
LN267
115V
1